Journal of Prosthetic Dentistry
Volume 85, Issue 4 , Pages 382-385 , April 2001

Immediate loading of single root form implants with the use of a custom acrylic stent

References 

  1. Adell R, Lekholm U, Rockler B, Branemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg. 1981;10:387–416
  2. Adell R, Eriksson B, Lekholm U, Branemark PI, Jemt T. Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. Int J Oral Maxillofac Implants. 1990;5:347–359
  3. Lindquist LW, Carlsson GE, Jemt T. A prospective 15-year follow-up study of mandibular fixed prosthesis supported by osseointegrated implants. Clinical results and marginal bone loss. Clin Oral Implants Res. 1996;7:329–336
  4. Jemt T, Lekholm U, Adell R. Osseointegration in the treatment of partially edentulous patients: a preliminary study of 876 consecutively placed fixtures. Int J Oral Maxillofac Implants. 1989;4:211–217
  5. Johns RB, Jemt T, Heath MR, Hutton JE, McKenna S, McNamara DC, et al.  A multicenter study of overdentures supported by Branemark implants. Int J Oral Maxillofac Implants. 1992;7:513–522
  6. Jemt T, Pettersson P. A 3-year follow-up study on single implant treatment. J Dent. 1993;21:203–208
  7. Branemark PI. Osseointegration and its experimental background. J Prosthet Dent. 1983;50:399–410
  8. Babbush CA, Kent JN, Misiek DJ. Titanium plasma-sprayed (TPS) screw implants for the reconstruction of the edentulous mandible. J Oral Maxillofac Surg. 1986;44:274–282
  9. Babbush CA. Titanium plasma spray screw implant system for reconstruction of the edentulous mandible. Dent Clin North Am. 1986;30:117–131
  10. Lefkove MD, Beals RP. Immediate loading of cylinder implants with overdentures in the mandibular symphisis: the titanium plasma-spray screw system. J Oral Implantol. 1990;16:265–271
  11. Chiapasco M, Gatti C, Rossi E, Haefliger W, Markwalder TH. Implant-retained mandibular overdentures with immediate loading. A retrospective multicenter study on 226 consecutive cases. Clin Oral Implants Res. 1997;8:48–57
  12. Schnitman PA, Wohrle PS, Rubenstein JE. Immediate fixed interim prostheses supported by two-stage threaded implants: methodology and results. J Oral Implantol. 1990;16:96–105
  13. Schnitman PA, Wohrle PS, Rubenstein JE, DaSilva JD, Wang NH. Ten-year results for Branemark implants immediately loaded with fixed prostheses at implant placement. Int J Oral Maxillofac Implants. 1997;12:495–503
  14. Tarnow DP, Emtiaz S, Classi A. Immediate loading of threaded implants at stage 1 surgery in edentulous arches: ten consecutive case reports with 1-to-5-year data. Int J Oral Maxillofac Implants. 1997;12:319–324
  15. Balshi TJ, Wolfinger GJ. Immediate loading of Branemark implants in edentulous mandibles: a preliminary report. Implant Dent. 1997;6:83–88
  16. Randow K, Ericsson I, Nilner K, Petersson A, Glantz PO. Immediate functional loading of Branemark dental implants. An 18-month clinical follow-up study. Clin Oral Implants Res. 1999;10:8–15
  17. Salama H, Rose LF, Salama M, Betts NJ. Immediate loading of bilaterally splinted titanium root-form implants in fixed prosthodontics—a technique reexamined: two case reports. Int J Periodontics Restorative Dent. 1995;15:344–361
  18. Levine RA, Rose L, Salama H. Immediate loading of root-form implants: two case reports 3 years after loading. Int J Periodontics Restorative Dent. 1998;18:333–343
  19. Piattelli A, Paolantonio M, Corigliano M, Scarano A. Immediate loading of titanium plasma-sprayed screw-shaped implants in man: a clinical and histological report of two cases. J Periodontol. 1997;68:591–597
  20. Gomes A, Lozada JL, Caplanis N, Kleinman A. Immediate loading of a single hydroxyapatite-coated threaded root form implant: a clinical report. J Oral Implantol. 1998;24:159–166
  21. Rangert B, Jemt T, Jorneus L. Forces and moments on Branemark implants. Int J Oral Maxillofac Implants. 1989;4:241–247
  22. Uhthoff HK. Mechanical factors influencing the holding power of screws in compact bone. J Bone Joint Surg Br. 1973;55:633–639
  23. Cameron HU, Pilliar RM, MacNab I. The effect of movement on the bonding of porous metal to bone. J Biomed Mater Res. 1973;7:301–311
  24. Brunski JB, Moccia AF, Pollack SR, Korostoff E, Trachtenberg DI. The influence of functional use of endosseous dental implants on the tissue-implant interface. I. Histological aspects. J Dent Res. 1979;58:1953–1969
  25. Aspenberg P, Goodman S, Toksvig-Larsen S, Ryd L, Albrektsson T. Intermittent micromotion inhibits bone ingrowth. Titanium implants in rabbits. Acta Orthop Scand. 1992;63:141–145
  26. Soballe K, Hansen ES, B-Rasmussen H, Jorgensen PH, Bunger C. Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions. J Orthop Res. 1992;10:285–299
  27. Goodman S, Wang JS, Doshi A, Aspenberg P. Difference in bone ingrowth after one versus two daily episodes of micromotion: experiments with titanium chambers in rabbits. J Biomed Mater Res. 1993;27:1419–1424
  28. Goodman SB. The effects of micromotion and particulate materials on tissue differentiation. Bone chamber studies in rabbits. Acta Orthop Scand Suppl. 1994;258:1–43
  29. Esposito M, Hirch JM, Lekholm U, Thomsen P. Biological factors contributing to failures of osseointegrated oral implants. (II). Etiopathogenesis. Eur J Oral Sci. 1998;106:721–764

 aAssistant Professor, Graduate Program in Implant Dentistry; Private practice limited to implant and prosthetic dentistry, Pasadena, Calif.

☆☆ bProfessor and Director, Graduate Program in Implant Dentistry.

 Reprint requests to: Dr Periklis Proussaefs Center for Prosthodontics and Implant Dentistry Loma Linda University School of Dentistry Loma Linda, CA 92350 Fax: (909)558-4803 E-mail: pProussaef00@sd.llu.edu.

★★ J Prosthet Dent 2001;85:382-5

PII: S0022-3913(01)17759-0

doi: 10.1067/mpr.2001.114841

Journal of Prosthetic Dentistry
Volume 85, Issue 4 , Pages 382-385 , April 2001