Journal of Prosthetic Dentistry
Volume 88, Issue 2 , Pages 145-150, August 2002

Tensile bond strength of acrylic resin denture teeth to a microwave- or heat-processed denture base☆☆★★

College of Dentistry, University of Iowa, Iowa City, Iowa

Abstract 

Statement of Problem. Fracture of acrylic resin prosthetic teeth from acrylic resin denture bases can be a problem for some patients. The optimal combination of acrylic resin denture tooth, denture base material, and processing method is not known. Purpose. The objective of this study was to compare the tensile bond strengths of heat- and microwave-polymerized acrylic resins among 4 types of acrylic resin denture teeth. Material and Methods. Heat-polymerized (Lucitone 199) and microwave-polymerized (Acron MC) acrylic resins were used. Four types of acrylic resin denture teeth (IPN, SLM, Vitapan, and SR-Orthotyp-PE) were milled to a fixed diameter according to ADA specification no. 15. Ten specimens of each tooth type were processed to each of the denture base materials according to the manufacturers' instructions. Ten additional resin control specimens without teeth also were fabricated. Specimens were thermocycled and tested for strength until fracture with a custom alignment device. Data were analyzed with analysis of variance and Duncan's multiple range test. A scanning electron microscope was used to identify adhesive and cohesive failures within debonded specimens. Results. The mean force required to fracture the specimens ranged from 5.3 ± 3.01 to 21.6 ± 5.2 MPa for the microwave-polymerized base and 11.2 ± 3.0 to 39.1 ± 5.1 MPa for the heat-polymerized base. The most common failure was cohesive within the denture tooth. With each base material, Orthotyp and IPN teeth exhibited the highest bond strengths; SLM and Orthotyp bond strengths were similar. In general, heat-polymerized groups failed cohesively within the denture base resin or the tooth, and microwave-polymerized groups failed adhesively at either the ridge lap or occlusal surface of the denture tooth. Conclusion. Within the limitations of this study, the results suggest that the type of denture base material and denture tooth selected for use may influence the tensile bond strength of the tooth to the base. Selection of more compatible combinations of base and resin teeth may reduce the number of prosthesis fractures and resultant repairs. (J Prosthet Dent 2002;88:145-50.)

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 15.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Reprint requests to: Dr Robert L. Schneider, Department of Prosthodontics, 424 Dental Science South, College of Dentistry S-413, The University of Iowa, Iowa City, IA 52242-1001, Fax: (319)353-4278, E-mail: robert-schneider@uiowa.edu

☆☆ aClinical Professor, Department of Prosthodontics.

 bOrthodontic resident.

★★ cAssociate Professor, Department of Prosthodontics.

PII: S0022-3913(02)00071-9

doi:10.1067/mpr.2002.127898

Journal of Prosthetic Dentistry
Volume 88, Issue 2 , Pages 145-150, August 2002