Journal of Prosthetic Dentistry
Volume 88, Issue 3 , Pages 290-296 , September 2002

Comparative study of circumferential clasp retention force for titanium and cobalt-chromium removable partial dentures

Abstract of Master's degree dissertation presented at the Ribeirão Preto School of Dentistry, São Paulo University. Major area: oral rehabilitation.

References 

  1. Blackman R, Barghi N, Tran C. Dimensional changes in casting titanium removable partial denture frameworks. J Prosthet Dent. 1991;65:309–315
  2. Iwama CY, Preston JD. Cobalt-chromium-titanium alloy for removable partial dentures. Int J Prosthodont. 1997;10:309–317
  3. Vallittu PK, Kokkonen M. Deflection fatigue of cobalt-chromium, titanium, and gold alloy cast denture clasp. J Prosthet Dent. 1995;74:412–419
  4. Canay S, Hersek N, Culha A, Bilgic S. Evaluation of titanium in oral conditions and its electrochemical corrosion behavior. J Oral Rehabil. 1998;25:759–764
  5. Lautenschlager EP, Monaghan P. Titanium and titanium alloys as dental materials. Int Dent J. 1993;43:245–253
  6. Wang RR, Fenton A. Titanium for prosthodontic applications: a review of the literature. Quintessence Int. 1996;27:401–408
  7. Thomas CJ, Lechner S, Mori T. Titanium for removable dentures. II. Two-year clinical observations. J Oral Rehabil. 1997;24:414–418
  8. Bridgeman JT, Marker VA, Hummel SK, Benson BW, Pace LL. Comparison of titanium and cobalt-chromium removable partial denture clasps. J Prosthet Dent. 1997;78:187–193
  9. Mori T, Togaya T, Jean-Louis M, Yabugami M. Titanium for removable dentures. I. Laboratory procedures. J Oral Rehabil. 1997;24:338–341
  10. Wang RR, Boyle AM. A simple method for inspection of porosity in titanium casting. J Prosthet Dent. 1993;70:275–276
  11. Hruska AR, Borelli P. Quality criteria for pure titanium casting, laboratory soldering, intraoral welding, and a device to aid in making uncontaminated castings. J Prosthet Dent. 1991;66:561–565
  12. Kononen M, Rintanen J, Waltimo A, Kempainen P. Titanium framework removable partial denture used for patient allergic to other metals: a clinical report and literature review. J Prosthet Dent. 1995;73:4–7
  13. Sunnerkrantz PA, Syverud M, Hero H. Effect of casting atmosphere on the quality of Ti-crowns. Scand J Dent Res. 1990;98:268–272
  14. Watanabe I, Watkins JH, Nakajima H, Atsuta M, Okabe T. Effect of pressure difference on the quality of titanium casting. J Dent Res. 1997;76:773–779
  15. McGivney GP, Carr AB. McCracken's removable partial prosthodontics. In: 10th ed. St. Louis (MO): : CV Mosby; 2000;p. 173–221

 Reprints request to: Dr Ricardo Faria Ribeiro, Ribeirão Preto School of Dentistry, São Paulo University, Av do Café, s/n Monte Alegre 14040-904, Ribeirão Preto, SP BRAZIL, E-mail: rribeiro@forp.usp.br

☆☆ Supported by grant No. 98/12553-2 from FAPESP.

 aGraduate student, Dental Materials and Prosthesis Department.

★★ bAssistant Professor of Removable Partial Prosthesis, Dental Materials and Prosthesis Department.

 cAssociate Professor of Removable Partial Prosthesis, Dental Materials and Prosthesis Department.

♢♢ dHead Professor of Removable Partial Prosthesis, Dental Materials and Prosthesis Department.

PII: S0022-3913(02)00200-7

doi: 10.1067/mpr.2002.128128

Journal of Prosthetic Dentistry
Volume 88, Issue 3 , Pages 290-296 , September 2002