Journal of Prosthetic Dentistry
Volume 88, Issue 5 , Pages 467-472 , November 2002

Fit of cast commercially pure titanium and Ti-6Al-4V alloy crowns before and after marginal refinement by electrical discharge machining

References 

  1. Bessing C, Bergman M. The castability of unalloyed titanium in three different casting machines. Swed Dent J. 1992;16:109–113
  2. Syverud M, Okabe T, Hero H. Casting of Ti-6Al-4V alloy compared with pure Ti in an Ar-arc casting machine. Eur J Oral Sci. 1995;103:327–330
  3. Lautenschlager EP, Monaghan P. Titanium and titanium alloys as dental materials. Int Dent J. 1993;43:245–253
  4. Lucas LC, Lemons JE. Biodegradation of restorative metallic systems. Adv Dent Res. 1992;6:32–37
  5. Wang RR, Fenton A. Titanium for prosthodontic applications: a review of the literature. Quintessence Int. 1996;27:401–408
  6. Zavanelli RA, Pessanha Henriques GE, Ferreira I, De Almeida Rollo JM. Corrosion-fatigue life of commercially pure titanium and Ti-6Al-4V alloys in different storage environments. J Prosthet Dent. 2000;84:274–279
  7. Walter M, Böning K, Reppel PD. Clinical performance of machined titanium restorations. J Dent. 1994;22:346–348
  8. Böening KW, Walter MH, Reppel PD. Non-cast titanium restorations in fixed prosthodontics. J Oral Rehabil. 1992;19:281–287
  9. Stoll R, Makris P, Stachniss V. Marginal adaptation of cast partial crowns made of pure titanium and a gold alloy under influence of a manual burnishing technique. J Oral Rehabil. 2001;28:401–406
  10. Van Roekel NB. Electrical discharge machining in dentistry. Int J Prosthodont. 1992;5:114–121
  11. Van Roekel NB. Prosthesis fabrication using electrical discharge machining. Int J Oral Maxillofac Implants. 1992;7:56–61
  12. Evans DB. Correcting the fit of implant-retained restorations by electric discharge machining. J Prosthet Dent. 1997;77:212–215
  13. Schmitt SM, Chance DA, Cronin RJ. Refining cast implant-retained restorations by electrical discharge machining. J Prosthet Dent. 1995;73:280–283
  14. Schmitt SM, Chance DA. Fabrication of titanium implant-retained restorations with nontraditional machining techniques. Int J Prosthodont. 1995;8:332–336
  15. Miyazaki T, Kitamura M, Hotta Y, Lee G. Development of fabrication system of prostheses using electric discharge machining. Asian J Aesthet Dent. 1993;1:71–79
  16. Rubeling G. Electroerosion in dental technology. Possibilities and limits. Dent Labor. 1982;30:1697–1702 German
  17. Andersson M, Bergman B, Bessing C, Ericson G, Lundquist P, Nilson H. Clinical results with titanium crowns fabricated with machine duplication and spark erosion. Acta Odontol Scand. 1989;47:279–286
  18. Karlsson S. The fit of Procera titanium crowns. An in vitro and clinical study. Acta Odontol Scand. 1993;51:129–134
  19. Leong D, Chai J, Lautenschlager E, Gilbert J. Marginal fit of machine-milled titanium and cast titanium single crowns. Int J Prosthodont. 1994;7:440–447
  20. Berg E. Dentists' opinions on aspects of cast titanium restorations. J Dent. 1997;25:113–117
  21. Linehan AD, Windeler AS. Passive fit of implant-retained prosthetic superstructures improved by electrical discharge machining. J Prosthodont. 1994;3:88–95
  22. Blackman R, Baez R, Barghi N. Marginal accuracy and geometry of cast titanium copings. J Prosthet Dent. 1992;67:435–440
  23. Hero H, Syverud M, Waarli M. Mold filing and porosity in castings of titanium. Dent Mater. 1993;9:15–18
  24. Bergman B, Bessing C, Ericson G, Lundquist P, Nilson H, Andersson M. A 2-year follow-up study of titanium crowns. Acta Odontol Scand. 1990;48:113–117
  25. Henriques GE, Consani S, Rollo JM, Andrade e Silva F. Soldering and remelting influence on fatigue strength of cobalt-chromium alloys. J Prosthet Dent. 1997;78:146–152
  26. Samet N, Resheff B, Gelbard S, Stern N. A CAD/CAM system for the production of metal copings for porcelain-fused-to-metal restorations. J Prosthet Dent. 1995;73:457–463
  27. McLean JW, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J. 1971;131:107–111
  28. Fransson B, Oilo G, Gjeitanger R. The fit of metal-ceramic crowns, a clinical study. Dent Mater. 1985;1:197–199

 Financially supported by State of São Paulo Research Foundation (FAPESP) grant Nos. 1999/03896-6 and 1999/03793-2.

☆☆ Reprint requests to: Dr Guilherme Elias Pessanha Henriques, Rua Campos Salles, 2006/92, CEP 13416-310, Piracicaba, São Paulo, BRAZIL, Fax: 00-55-19 4305218, E-mail: guilherm@fop.unicamp.br

 aPhD candidate, State University of Campinas.

★★ bAssociate Professor, Department of Prosthodontics, State University of Campinas.

 cAssistant Professor, Department of Statistics, Federal University of Paraná.

♢♢ dAssociate Professor, Department of Prosthodontics, State University of Campinas.

PII: S0022-3913(02)00253-6

doi: 10.1067/mpr.2002.128954

Journal of Prosthetic Dentistry
Volume 88, Issue 5 , Pages 467-472 , November 2002