Journal of Prosthetic Dentistry
Volume 88, Issue 6 , Pages 604-610 , December 2002

Fatigue resistance of two implant/abutment joint designs

Presented in two parts at the 30th American Association for Dental Research annual meeting, Chicago, Ill., March 2001, and the 79th International Association for Dental Research meeting, Chiba, Japan, June 2001.

References 

  1. Adell R, Eriksson B, Lekholm U, Branemark PI, Jemt T. Long-term follow-up of osseointegrated implants in the treatment of totally edentulous jaws. Int J Oral Maxillofac Implants. 1990;5:347–359
  2. Cochran DL. The scientific basis for and clinical experiences with Straumann implants including the ITI Dental Implant System: a consensus report. Clin Oral Implants Res. 2000;11(Suppl):33–58
  3. Bahat O. Branemark system implants in the posterior maxilla: clinical study of 660 implants followed for 5 to 12 years. Int J Oral Maxillofac Implants. 2000;15:646–653
  4. Jemt T, Linden B, Lekholm U. Failures and complications in 127 consecutively placed fixed partial prostheses supported by Branemark implants: from prosthetic treatment to first annual checkup. Int J Oral Maxillofac Implants. 1992;7:40–44
  5. Jemt T, Lekholm U, Grondahl K. 3-year follow up study of early single implant restorations ad modum Branemark. Int J Periodontics Restorative Dent. 1990;10:340–349
  6. Scheller H, Urgell JP, Kultje C, Klineberg I, Goldberg PV, Stevenson-Moore P, et al.  A 5-year multicenter study on implant-supported single crown restorations. Int J Oral Maxillofac Implants. 1998;13:212–218
  7. Jemt T, Pettersson P. A 3-year follow-up study on single implant treatment. J Dent. 1993;21:203–208
  8. Sakaguchi RL, Borgersen SE. Nonlinear contact analysis of preload in dental implant screws. Int J Oral Maxillofac Implants. 1995;10:295–302
  9. Burguete RL, Johns RB, King T, Patterson EA. Tightening characteristics for screwed joints in osseointegrated dental implants. J Prosthet Dent. 1994;71:592–599
  10. Merz BR, Hunenbart S, Belser UC. Mechanics of the implant-abutment connection: an 8-degree taper compared to a butt joint connection. Int J Oral Maxillofac Implants. 2000;15:519–526
  11. Sutter F, Weber HP, Sorensen J, Belser U. The new restorative concept of the ITI dental implant system: Design and engineering. Int J Periodontics Restorative Dent. 1993;13:409–431
  12. Basten CH, Nicholls JI, Daly CH, Taggart R. Load fatigue performance of two implant-abutment combinations. Int J Oral Maxillofac Implants. 1996;11:522–528
  13. Binon PP. The role of screws in implant systems. Int J Oral Maxillofac Implants. 1994;9(Suppl):48–63
  14. Norton MR. An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design. Clin Oral Implants Res. 1997;8:290–298
  15. Mollersten L, Lockowandt P, Linden LA. Comparison of strength and failure mode of seven implant systems: an in vitro test. J Prosthet Dent. 1997;78:582–591
  16. Rangert B, Krogh PH, Langer B, Van Roekel N. Bending overload and implant fracture: a retrospective clinical analysis. Int J Oral Maxillofac Implants. 1995;10:326–334
  17. Henry PJ, Laney WR, Jemt T, Harris D, Krogh PH, Polizzi G, et al.  Osseointegrated implants for single-tooth replacement: a prospective 5-year multicenter study. Int J Oral Maxillofac Implants. 1996;11:450–455
  18. Laney WR, Jemt T, Harris D, Henry PJ, Krogh PH, Polizzi G, et al.  Osseointegrated implants for single-tooth replacement: progress report from a multicenter prospective study after 3 years. Int J Oral Maxillofac Implants. 1994;9:49–54
  19. Jemt T, Laney WR, Harris D, Henry PJ, Krogh PH, Polizzi G, et al.  Osseointegrated implants for single tooth replacement: a 1-year report from a multicenter prospective study. Int J Oral Maxillofac Implant. 1991;6:29–36
  20. Levine RA, Clem DS, Wilson TG, Higginbottom F, Solnit G. Multicenter retrospective analysis of the ITI implant system used for single-tooth replacements: results of loading for 2 or more years. Int J Oral Maxillofac Implants. 1999;14:516–520
  21. Levine RA, Clem DS, Wilson TG, Higginbottom F, Saunders SL. A multicenter retrospective analysis of the ITI implant system used for single-tooth replacements: preliminary results at 6 or more months of loading. Int J Oral Maxillofac Implants. 1997;12:237–242
  22. Craig RG. Restorative dental materials. In: 9th ed. St Louis: Mosby; 1993;p. 75–77
  23. Versluis A, Korioth TW, Cardoso AC. Numerical analysis of a dental implant system preloaded with a washer. Int J Oral Maxillofac Implants. 1999;14:337–341
  24. Lekholm U, Gunne J, Henry P, Higuchi K, Linden U, Bergstrom C, et al.  Survival of the Branemark implant in partially edentulous jaws: a 10-year prospective multicenter study. Int J Oral Maxillofac Implants. 1999;14:639–645
  25. Parel SM. Esthetic implant restorations. In: 1st ed. Taylor Publishing Company; 1996;p. 93–94
  26. Andersson B, Ödman P, Boss A, Jörnéus L. Mechanical Testing of superstructures on the CeraOne abutment in the Brånemark system. Int J Oral Maxillofac Implants. 1994;9:665–672
  27. Scacchi M, Merz BR, Schär AR. The development of the ITI dental implant system. Part 2: 1998-2000: Steps into the next millenium. Clin Oral Implants Res. 2000;11(Suppl):22–32
  28. Scacchi M. The development of the ITI dental implant system. Part 1: A review of the literature. Clin Oral Implants Res. 2000;11(Suppl):8–21
  29. Mericske-Stern R, Zarb GA. In vivo measurements of some functional aspects with mandibular fixed prostheses supported by implants. Clin Oral Implants Res. 1996;7:153–161
  30. Timoshenko S, MacCullough GH. Elements of strength of materials. In: 3rd ed. Tokyo, Japan: Maruzen Company; 1949;p. 91–118
  31. Mohl ND, Zarb GA, Carlsson GE, Rugh JD. A textbook of occlusion. In: Chicago: Quintessence; 1988;p. 143–152

 Supported by a Grant-in-Aid for Scientific Research (project no. 11771213), Japan Ministry of Education, Culture, Sports, Science and Technology.

☆☆ Reprint requests to: Dr Ameen Khraisat, Division of Oral Health in Aging and Fixed Prosthodontics, Graduate School of Medical and Dental Sciences, Niigata University, Gakko-Cho-Dori 2-5274, Niigata 951-8514, JAPAN, Fax: (81) 25-227-0809, E-mail: ameen@dent.niigata-u.ac.jp

 aPostgraduate student, Division of Oral Health in Aging and Fixed Prosthodontics.

★★ bAssistant Professor, Division of Oral Health in Aging and Fixed Prosthodontics.

 cProfessor and Chairman, Division of Oral Health in Aging and Fixed Prosthodontics.

♢♢ dProfessor and Chairman, Division of Dental Biomaterial Science.

PII: S0022-3913(02)00295-0

doi: 10.1067/mpr.2002.129384

Journal of Prosthetic Dentistry
Volume 88, Issue 6 , Pages 604-610 , December 2002