Journal of Prosthetic Dentistry
Volume 87, Issue 1 , Pages 40-44, January 2002

Prosthetic complications in an implant-retained mandibular overdenture population: Initial analysis of a prospective study☆☆★★♢♢

School of Dentistry, University of North Carolina, Chapel Hill, N.C

Abstract 

Statement of Problem. The clinical success of implant-retained, tissue-supported mandibular overdenture prostheses has been documented. However, few studies have evaluated the return visits and associated cost required to maintain these prostheses. Purpose. The purpose of this investigation was to evaluate the amount of maintenance required to provide acceptable and satisfactory implant-retained mandibular overdentures in a prospective clinical trial. Material and Methods. Fifty-eight patients received new maxillary and mandibular complete dentures followed by placement of microthreaded/TiOBlast implants in the mandibular left and right canine regions. At 3 months, ball abutments were placed, and the mandibular prostheses were relined to receive Dalla Bona-type ball housings (baseline). Prostheses were prospectively evaluated, and adjustments were made at 3-, 6-, 12-, 24-, and 36-month recall visits and at nonscheduled visits for 9 types of prosthetic complications. Results. Of 58 patients, 6 required no adjustments. The remaining 52 patients made 327 return visits (including 194 nonscheduled visits) for prosthesis and/or abutment adjustments. One hundred and fifteen practitioner hours were required to provide prosthetic solutions to patient concerns at the return visits. The total estimated cost for all professional and laboratory services was $12,624.00 ($218.00 per patient). Conclusion. Although mandibular implant-supported overdentures with Dalla Bona-type ball attachments are an acceptable treatment option for edentulous patients, routine maintenance is required to ensure successful long-term outcomes. (J Prosthet Dent 2002;87:40-4.)

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 15.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 This research was funded by a grant from Astra Tech AB, Molndal, Sweden.

☆☆ aAssistant Professor, Department of Prosthodontics.

 bAssociate Professor and Chair, Department of Prosthodontics.

★★ cAssociate Professor, Department of Prosthodontics.

 dDirector, Clinical Research, Astra Tech AB, Molndal, Sweden.

♢♢ eClinical Director, Astra Tech Inc, Lexington, Mass.

 Reprint requests to: Dr Nancy R. Chaffee, Department of Prosthodontics, 404 Brauer Hall, CB 7450, UNC School of Dentistry, Chapel Hill, NC 27599-7450, Fax: (919)966-3821, E-mail: nchaffee@earthlink.net

PII: S0022-3913(02)37798-9

doi:10.1067/mpr.2002.121486

Journal of Prosthetic Dentistry
Volume 87, Issue 1 , Pages 40-44, January 2002