Journal of Prosthetic Dentistry
Volume 89, Issue 3 , Pages 250-255, March 2003

Accuracy of open tray implant impressions: An in vitro comparison of stock versus custom trays☆☆★★♢♢

Guys Hospital, London, England

Abstract 

Statement of Problem. The accuracy of an implant fixture-level impression is affected by the type of impression tray used. Purpose. The purpose of this in vitro study was to investigate the accuracy of open tray implant impressions comparing polycarbonate stock impression trays and rigid custom-made impression trays to make implant fixture-level impressions. Material and Methods. Gold cylinder pairs, splinted by gold bars (reference frameworks) were constructed on an aluminum typodont. Polyether impressions were made of 2 pairs of Brånemark 3.75-mm diameter fixtures mounted in an aluminium typodont, with 3 stock impression trays, 3 close-fit custom trays, and 3 spaced custom impression trays, by use of an open tray technique. The casts produced were assessed for accuracy by attaching the reference frameworks with alternate single screws and measuring the vertical fit discrepancy of these reference frameworks to the analogs within the working cast using a traveling microscope. Comparison of gap dimensions by tray type was performed with a nonparametric Kruskal-Wallis analysis of variance (ANOVA) followed by pair-wise Mann-Whitney U tests. To adjust for multiple comparisons in the post-ANOVA contrasts (P<.02). Comparison of gap dimensions between anterior and posterior regions were performed with Mann-Whitney U tests (P <.05). Results. The results showed that the mean fit accuracy, as measured by vertical fit discrepancy, of casts from the stock trays (23 ± 20 μm) were statistically significantly less (P<.001) than the spaced custom trays (12 ± 10 μm) or close fit custom trays (11 ± 10 μm). The difference in median gap size for analogs with a 20-mm separation was 10 μm. Conclusion. Within the limits of this in vitro study, rigid custom trays produced significantly more accurate impressions than the polycarbonate stock trays. The stock trays used in this study could not produce accurate impressions consistently. For analogs with a 20-mm separation, there was a difference in medians of 10 μm in accuracy between the stock and custom trays. (J Prosthet Dent 2003;89:250-5.)

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 15.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Reprint requests to: Dr Jason Burns, 320 Kew Road, Richmond, Surrey, TW9 3DU, UNITED KINGDOM, E-mail: jason@molars.com

☆☆ aPrivate practice, London, England.

 bProfessor of Periodontology and Implant Dentistry.

★★ cConsultant in Restorative Dentistry.

 dDental Clinical Research.

♢♢ 0022-3913/2003/$30.00 + 0

PII: S0022-3913(02)52706-2

doi:10.1067/mpr.2003.38

Journal of Prosthetic Dentistry
Volume 89, Issue 3 , Pages 250-255, March 2003