« Previous
Next »
Journal of Prosthetic Dentistry
Volume 89, Issue 3
, Pages 256-260
, March 2003
Fit of implant frameworks: An in vitro comparison between two fabrication techniques
References
- . Measurements of bone and frame-work deformations induced by misfit of implant superstructures: A pilot study in rabbits. Clin Oral Implants Res. 1998;9:272–280
- . Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implants. 1994;9:169–178
- . Three-dimensional analysis of the casting accuracy of one-piece, osseointegrated implant-retained prostheses. Int J Prosthodont. 1993;6:346–363
- . Photogrammetric measurements of implant positions. Description of a technique to determine the fit between implants and superstructures. Clin Oral Implants Res. 1994;5:30–36
- . Accuracy of implant-supported prostheses in the edentulous jaw: Analysis of precision of fit between cast gold-alloy frameworks and master casts by means of a three-dimensional photogrammetric technique. Clin Oral Implants Res. 1995;6:172–180
- . Three-dimensional distortion of gold-alloy casting and welded titanium frameworks: measurements of the precision of fit between completed implant prostheses and the master casts in routine edentulous situations. J Oral Rehabil. 1995;22:557–564
- . Prosthesis misfit and marginal bone loss in edentulous implant patients. Int J Oral Maxillofac Implants. 1996;11:620–625
- . A prospective 15-year follow-up study of mandibular fixed prostheses supported by osseointegrated implants: clinical results and marginal bone loss. Clin Oral Implants Res. 1996;7:329–336
- . Measuring fit at the implant prosthodontic interface. J Prosthet Dent. 1996;75:314–325
- . In vivo measurements of precision of fit involving implant-supported prostheses in the edentulous jaw. Int J Oral Maxillofac Implants. 1996;11:151–158
- . Fit of implant frameworks fabricated by different techniques. J Prosthet Dent. 1997;78:596–604
- . Clinical methods for evaluating implant framework fit. J Prosthet Dent. 1999;81:7–13
- . Clinical results with titanium crowns fabricated with machine duplication and spark erosion. Acta Odontol Scand. 1989;47:279–286
- . A 2-year follow-up study of titanium crowns. Acta Odontol Scand. 1990;48:113–117
- . The fit of Procera titanium crowns: an in vitro and clinical study. Acta Odontol Scand. 1993;51:129–134
- . The accuracy of a high-precision digitizer for CAD/CAM of crowns. J Prosthet Dent. 1995;74:223–229
- . Accuracy of machine milling and spark erosion with a CAD/CAM system. J Prosthet Dent. 1996;76:187–193
- . Experimental study on the influence of various dental luting cements on the elevation of crown during cementation. Shikwa Gakuho. 1989;89:1317–1337 [Japanese]
-
.
Mobility characteristics and tactile sensitivity of osseointegrated fixture-supporting system.
In:
van Steenberghe U editors.
Tissue integration in oral and maxillofacial reconstructions. New York: Elsevier Science; 1987;p. 326–332
☆ Supported by the Department of Odontology/Faculty of Medicine and Odontology, Umeå University and Umeå Dental Laboratory, Umeå, Sweden.
☆☆ Reprint requests to: Dr Toshiyuki Takahashi, Department of Crown and Bridge Prosthodontics, Tokyo Dental College, 1-2-2, Masago, Mihama-ku, Chiba 261-8502, JAPAN, E-mail: totakaha@tdc.ac.jp
★ aAssistant Professor, Department of Crown and Bridge Prosthodontics, Tokyo Dental College. Guest researcher, Department of Odontology/Prosthetic Dentistry, Faculty of Medicine and Odontology, Umeå University.
★★ bProfessor, Department of Odontology/Prosthetic Dentistry, Faculty of Medicine and Odontology, Umeå University.
♢ 0022-3913/2003/$35.00 + 0
PII: S0022-3913(02)52708-6
doi: 10.1067/mpr.2003.40
© 2003 Editorial Council of The Journal of Prosthetic Dentistry. Published by Elsevier Inc All rights reserved.
« Previous
Next »
Journal of Prosthetic Dentistry
Volume 89, Issue 3
, Pages 256-260
, March 2003

