In vitro kinetic study of absorbency of retraction cords☆☆★★♢♢

Faculty of Dentistry, Semmelweis University, Budapest, Hungary

Abstract 

Statement of problem. The soaking time required for liquid uptake by retraction cords is a crucial factor in the successful gingival retraction procedure. Purpose. The aim of this investigation was to determine the optimal soaking time for 3 retraction cords of different thickness to ensure adequate uptake of the hemostatic solution. Material and methods. Braided ULTRAPAC retraction cords of 3 different thicknesses (No. 00, No. 0, and No. 1) with identical lengths (35 mm) were used. The capability of the cords to absorb liquids was measured by a gravimetric method. Different sulcus retraction solutions (epinephrine, aluminum chloride, and ferric sulfate) were tested, with physiological saline solution used as the control. The cords were soaked for various time intervals (2 seconds; 1, 5, and 60 minutes; and 24 hours) in the medicament solutions at room temperature. Immediately before immersion, air inclusions that may have inhibited the inner moistening of the cords were manually pressed out. In each of the 4 treatment groups, 75 pieces of cord were tested by determining the grams of fluid absorbed by grams of dry cord (gram/gram). Before the cord was weighed, excess fluid accumulating on the outer surface of the cord was removed by filter paper saturated in the corresponding test solution. The data were analyzed by F test analysis, and P<.05 was regarded as significant. Results. In each group, regardless of the cord type (No. 00, No. 0, or No. 1) or medicament solutions tested, the amount of fluid absorbed increased with the soaking time, but to different extents. A logarithmic relationship in a linear plot between the amount of fluid absorbed and the soaking time was demonstrated. The relationship established offered an exact determination of both the rate and the saturation level of liquid uptake. The rate of liquid uptake calculated from the saturation equations exhibited significant correlation with the cord thickness (P<.05). The saturation levels of the solutions did not show correlation with the cord thickness (P>.30). Conclusion. Within the limitations of this study, the results indicated that 20 minutes of soaking time was necessary for saturation of the cords before use, provided that air trapped within the cords was removed. In addition to the soaking time, the saturation of the cords with the solutions largely depended on the wetting of the cords. (J Prosthet Dent 2003;89:45-9.)

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 15.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 This work was supported by the National Science Foundation (OTKA T-023601) and the Ministry of Health (ETT-30/2000).

☆☆ Reprint requests to: Dr Ferenc Csempesz, Department of Conservative Dentistry, Semmelweis University, H-1088 Budapest, Mikszath Ter 5, HUNGARY, Fax: 36-1-317-1122, E-mail: csempesz@konfog.sote.hu

 aPhD student, Department of Conservative Dentistry.

★★ bPhD student, Department of Conservative Dentistry.

 cProfessor and Director, Department of Conservative Dentistry.

♢♢ 0022-3913/2003/$30.00 + 0

PII: S0022-3913(02)52761-X

doi:10.1067/mpr.2003.61

Journal of Prosthetic Dentistry
Volume 89, Issue 1 , Pages 45-49, January 2003