Journal of Prosthetic Dentistry
Volume 90, Issue 4 , Pages 325-331 , October 2003

In vivo fracture resistance of implant-supported all-ceramic restorations

  • Murat Yildirim, DMD, PhD

      Affiliations

    • Associate Professor, Department of Prosthodontics, Aachen, Germany
    • Corresponding Author InformationReprint requests to: Dr Murat Yildirim, Department of Prosthodontics, University of Aachen, Medical Center, Pauwelsstr. 30, 52074 Aachen, Germany, Fax: 49-241-808-2410
  • ,
  • Horst Fischer, Dr ing

      Affiliations

    • Technical Assistant, Department of Prosthodontics, Aachen, Germany
  • ,
  • Rudolf Marx, PhD, Dr rer nat

      Affiliations

    • Associate Professor, Department of Prosthodontics, Aachen, Germany
  • ,
  • Daniel Edelhoff, DMD

      Affiliations

    • Assistant Professor, Department of Prosthodontics, Aachen, Germany

References 

  1. Ida K, Togaya T, Tsutsumi S, Takeuchi M. Effect of magnesia investments in the dental casting of pure titanium or titanium alloys. Dent Mater. 1982;1:8–22
  2. Willmann G. Oxide ceramics for articulating components of THPs-ceramic/polyethylene ceramic/ceramic. In:  Wilson J,  Hench LL,  Greenspan D editor. Bioceramics. New York: Elsevier Science; 1995;p. 206
  3. Scherrer SS, Kelly JR, Quinn GD, Xu K. Fracture toughness (KIc) of a dental porcelain determined by fractographic analysis. Dent Mater. 1999;15:342–348
  4. Christel P, Meunier A, Heller M, Torre JP, Peille CN. Mechanical properties and short term in-vivo evaluation of yttrium-oxide-partially-stabilized zirconia. J Biomed Mater Res. 1989;23:45–61
  5. Ichikawa Y, Akagawa Y, Nikai H, Tsuru H. Tissue compatibility and stability of a new zirconia ceramic in vivo. J Prosthet Dent. 1992;68:322–326
  6. Cales B, Stefani Y, Lilley E. Long-term in vivo and in vitro aging of zirconia ceramic used in orthopaedy. J Biomed Mater Res. 1994;28:619–624
  7. Piconi C, Maccauro G. Zirconia as a ceramic biomaterial. Biomaterials. 1999;20:1–25
  8. Kosmac T, Oblak C, Jevnikar P, Funduk N, Marion L. The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic. Dent Mater. 1999;15:426–433
  9. Beumer J, III, Lewis G S. The Brånemark implant system—clinical and laboratory procedures. St. Louis: Ishiyaku EuroAmerica; 1989
  10. Yildirim M, Edelhoff D, Hanisch O, Spiekermann H. Ceramic abutments—a new era in achieving optimal esthetics in implant dentistry. Int J Periodontics Restorative Dent. 2000;20:81–91
  11. Dong JK, Lüthy H, Wohlwend A, Schärer P. Heat-pressed ceramics (technology and strength). Int J Prosthodont. 1992;5:9–16
  12. Mak M, Qualtrough AJ, Burke FJ. The effect of different ceramic materials on the fracture resistance of dentin-bonded crowns. Quintessence Int. 1997;28:197–203
  13. Seghi RR, Sorensen JA. Relative flexural strength of six new ceramic materials. Int J Prosthodont. 1995;8:239–246
  14. Seghi RR, Denry IL, Rosenstiel SF. Relative fracture toughness and hardness of new dental ceramics. J Prosthet Dent. 1995;74:145–150
  15. Strub JR, Beschnidt SM. Fracture strength of 5 different all-ceramic crown systems. Int J Prosthodont. 1998;11:602–609
  16. Fradeani M, Aquilano A. Clinical experience with Empress crowns. Int J Prosthodont. 1997;10:241–247
  17. Sjögren G, Lantto R, Granberg Å, Sundström BO, Tillberg A. Clinical examination of leucite-reinforced glass-ceramic crowns (Empress) in general practice (a retrospective study). Int J Prosthodont. 1999;12:122–128
  18. Sorensen JA, Choi C, Fanuscu MI, Mito WT. IPS Empress crown system (three-year clinical trial results). J Calif Dent Assoc. 1998;26:130–136
  19. Munz D, Fett T. Ceramics: mechanical properties, failure behavior, materials selection. 1st ed. New York: Springer-Verlag; 1999;
  20. Luthardt RG, Holzhuter M, Sandkuhl O, Herold V, Schnapp JD, Kuhlisch E, et al. Reliability and properties of ground Y-TZP-zirconia ceramics. J Dent Res. 2002;81:487–491
  21. Paphangkorakit J, Osborn JW. The effect of pressure on maximum incisal bite force in man. Arch Oral Biology. 1997;42:11–17
  22. Haraldson T, Carlsson GE, Ingervall B. Functional state, bite force and postural muscle activity in patients with osseointegrated oral implant bridges. Acta Odontol Scand. 1979;37:195–206
  23. Probster L. Compressive strength of two modern all-ceramic crowns. Int J Prosthodont. 1992;5:409–414
  24. Burstein AH, Wright TM. Fundamentals of orthopedic biomechanics. 1st ed. Baltimore: Lippincott Williams & Wilkins; 1994;
  25. Kern M, Strub JR. Bonding to alumina ceramic in restorative dentistry (clinical results over up to 5 years). J Dent. 1998;26:245–249
  26. Blixt M, Adamczak E, Lindén LA, Odén A, Arvidson K. Bonding to densely sintered alumina surfaces (effect of sandblasting and silica coating on shear bond strength of luting cements). Int J Prosthodont. 2000;13:221–226
  27. Groten M, Probster L. The influence of different cementation modes on the fracture resistance of feldspathic ceramic crowns. Int J Prosthodont. 1997;10:169–177
  28. Dérand P, Dérand T. Bond strength of luting cements to zirconium oxide ceramics. Int J Prosthodont. 2000;13:131–135
  29. Edelhoff D, Marx R, Spiekermann H, Yildirim M. Clinical use of an intraoral silicoating technique. J Esthet Restor Dent. 2001;13:350–356

PII: S0022-3913(03)00514-6

doi: 10.1016/S0022-3913(03)00514-6

Journal of Prosthetic Dentistry
Volume 90, Issue 4 , Pages 325-331 , October 2003