« Previous
Next »
Journal of Prosthetic Dentistry
Volume 90, Issue 5
, Pages 434-440
, November 2003
Evaluation of dental arch reproduction using three-dimensional optical digitization
References
- . The accuracy of highly filled elastomeric impression materials. J Prosthet Dent. 1975;33:67–72
- . Time-dependent accuracy of elastomeric impression materials. Part II (polyether, polysulfides, and polyvinylsiloxane). J Prosthet Dent. 1981;45:329–333
- . Vinyl polysiloxane impression materials (a status report. Council of Dental Materials, Instruments and Equipment). J Am Dent Assoc. 1990;120:595–596 -600
- . Elastomeric impression materials (effect of bulk on accuracy). J Prosthet Dent. 1979;41:304–307
- . Accuracy of four types of rubber impression materials compared with time of pour and a repeat pour of models. J Prosthet Dent. 1985;53:484–490
- . The effect of tray selection on the accuracy of elastomeric impression materials. J Prosthet Dent. 1990;63:12–15
- . The effect of using custom or stock trays on the accuracy of gypsum casts. Int J Prosthodont. 1996;9:367–373
- . A laboratory study of dimensional changes for three elastomeric impression materials using custom and stock trays. Aust Dent J. 1996;4:398–404
- . Determining the accuracy of stock and custom tray impression/casts. J Oral Rehabil. 1998;25:645–648
- . The effects of custom tray material on the accuracy of master casts. J Prosthodont. 1998;7:106–110
- . Accuracy of three polyvinyl siloxane putty-wash impression techniques. J Prosthet Dent. 2000;83:161–165
- . Accuracy of addition silicones as a function of technique. J Prosthet Dent. 1986;55:197–203
- . Effect of impression tray design upon the accuracy of stone casts produced from a single-phase medium-bodied polyvinyl siloxane impression material. J Dent. 1992;20:189–192
- . Dimensional accuracy of dental casts (influence of tray material, impression material, and time). J Prosthodont. 2002;11:98–108
- . Laser digitization of casts to determine the effect of tray selection and formation technique on accuracy. J Prosthet Dent. 2002;87:204–209
- . Accuracy of a hydrophilic irreversible hydrocolloid/silicone impression material. J Prosthet Dent. 1986;55:304–308
- . Dimensional stability of elastomeric impression materials in custom-made and stock trays. J Prosthet Dent. 1984;52:514–517
- . The influence of impression trays on the accuracy of stone casts poured from irreversible hydrocolloid impressions. J Prosthet Dent. 1985;54:383–388
- . Accuracy of stone cast produced by perforated trays and nonperforated trays. J Prosthet Dent. 1985;53:347–350
- . Effect of impression tray design and impression technique upon the accuracy of stone casts produced from a putt-wash polyvinyl siloxane impression material. J Dent. 1991;19:283–289
- . Distortion analysis of stone casts made from impression materials. J Prosthet Dent. 1985;54:794–802
- . Use of a scanning laser three-dimensional digitizer for analysis of dental materials. Biomed Instrum Technol. 1991;25:60–67
- . Use of a scanning laser three-dimensional digitizer to evaluate dimensional accuracy of dental impression materials. J Prosthet Dent. 1992;68:229–235
- . Elastic recovery of polysulfide base impressions. J Dent Res. 1972;51:773–779
- . Effect of material bulk and undercuts on the accuracy of impression materials. J Prosthet Dent. 1985;54:791–794
-
.
Phillips' science of dental materials.
In: 10th ed. St Louis: Elsevier; 1996;p. 170
- . Accurate casts. J Prosthet Dent. 1969;21:545–554
- . A study of distortion and surface hardness of improved artificial stone casts. J Prosthet Dent. 1976;36:373–381
-
.
Fundamentals of fixed prosthodontics.
In: 3rd ed.. Chicago: Quintessence; 1997;p. 311
- . Effect of impression technique and multiple pours on accuracy of stone models. J Dent Assoc S Afr. 1991;46:515–518
- . Development and evaluation of a new 3-D digitization and computer graphic system to study the anatomic tissue and restoration surfaces. J Oral Rehabil. 1996;23:25–34
- . A new optical 3-D device for the detection of wear. J Dent Res. 1997;76:1799–1807
- . Quantitative measurement of volume changes induced by oral plastic surgery (validation of an optical method using different geometrically-formed specimens). J Periodontol. 1997;68:950–962
- . A new, three-dimensional method for determining tooth wear. Am J Phys Anthropol. 1997;103:463–469
- . Accuracy of a system for creating 3D computer models of dental tissues. J Dent Res. 2003;82:438–442
☆ Research for this article was supported in part by The University of Minnesota School of Dentistry Summer Research Fellowship Program NIH/5T35-DE07098-19, 2R44DE11638 and NIH/NIDCR Grant P30-DE12225 and The Minnesota Research Center for Biomaterials and Biomechanics.
PII: S0022-3913(03)00592-4
doi: 10.1016/j.prosdent.2003.08.021
© 2003 The Editorial Council of The Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Journal of Prosthetic Dentistry
Volume 90, Issue 5
, Pages 434-440
, November 2003

