« Previous
Next »
Journal of Prosthetic Dentistry
Volume 91, Issue 3
, Pages 234-240
, March 2004
The influence of implant location and length on stress distribution for three-unit implant-supported posterior cantilever fixed partial dentures
References
- . The longitudinal clinical effectiveness of osseointegrated dental implants in posterior partially edentulous patients. Int J Prosthodont. 1993;6:189–196
- . Patient evaluation of treatment with fixed implant-supported partial dentures. J Oral Rehabil. 2001;28:998–1002
- . Implant-supported fixed partial prostheses: a retrospective study. Int J Prosthodont. 2003;16:172–176
- . The original one-stage dental implant system and its clinical application. Periodontol 2000. 1998;17:106–118
- . Influence of restoration type on stress distribution in bone around implants: a three-dimensional finite element analysis. Int J Oral Maxillofac Implants. 1998;13:82–90
- . Finite element analysis on dental implant-supported prostheses without passive fit. J Prosthodont. 2002;11:30–40
- . A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg. 1981;10:387–416
- . Comparative three-dimensional analysis of two finite-element endosseous implant designs. J Oral Implantol. 1994;20:315–321
- . Osseointegration and its experimental background. J Prosthet Dent. 1983;50:399–410
-
.
Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys.
Clin Oral Impl Res. 1996;7:143–152
- . Fractures of the fixture component of an osseointegrated implant. Int J Oral Maxillofac Implants. 1993;8:409–414
- . Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog. J Oral Rehabil. 1998;25:847–858
- . Dental implant design: Effect on bone remodeling. J Biomed Mater Res. 1991;25:467–483
- . Biomechanical considerations in dental implant design. Int J Oral Implantol. 1988;5:31–34
- . Evaluating parameters of osseointegrated dental implants using finite element analysis-a two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction. J Oral Implantol. 1998;24:80–88
- . Stress distribution around dental implants: influence of superstructure, length of implants, and height of mandible. J Prosthet Dent. 1992;68:96–102
- . Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the bone. J Dent. 2002;30:41–46
- . Numeric approach to the biomechanical analysis of thermal effects in coated implants. Int J Prosthodont. 1993;6:564–572
-
In:
Bever MB editors. Encyclopedia of materials science and engineering. Oxford: Pergamon Press; 1986;p. 1059
- . Finite element analysis of three- and four-unit bridges. J Oral Rehabil. 1989;16:603–611
- . Occlusal force and oral tactile sensibility measured in partially edentulous patients with ITI implants. Int J Oral Maxillofac Implants. 1995;10:345–353
-
.
Elasticity: Tensor, Dyadic, and Engineering Approaches.
New York: Dover Publications; 1967;
p.55
☆ Presented at the 81st General Session of the International Association for Dental Research, Göteborg, Sweden, June 2003.Supported by Grants in Aid for Scientific Research, 12771170 (N.W.) and 14571840 (N.W.), from The Ministry of Education, Science, and Culture of Japan.
PII: S0022-3913(03)00861-8
doi: 10.1016/j.prosdent.2003.12.017
© 2004 The Editorial Council of The Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Journal of Prosthetic Dentistry
Volume 91, Issue 3
, Pages 234-240
, March 2004

