Journal of Prosthetic Dentistry
Volume 94, Issue 4 , Pages 370-376, October 2005

Changes in gloss after simulated generalized wear of composite resins

  • Yong-Keun Lee, DDS, PhD

      Affiliations

    • Associate Professor, Department of Dental Biomaterials Science, College of Dentistry, Seoul National University
    • Corresponding Author InformationReprint requests to: Dr Yong-Keun Lee, Associate Professor, Department of Dental Biomaterials Science, College of Dentistry, Seoul National University, 28 Yeongeon-dong, Jongro-gu, Seoul, REPUBLIC OF KOREA, Fax: 82-2-740-8694
  • ,
  • Huan Lu, DDS, PhD

      Affiliations

    • Assistant Professor of Oral Biomaterials, Department of Restorative Dentistry and Biomaterials, Houston Biomaterials Research Center, University of Texas Dental Branch at Houston
  • ,
  • Makoto Oguri

      Affiliations

    • Scientist, Tokuyama Dental Corp
  • ,
  • John M. Powers, PhD

      Affiliations

    • Professor, Department of Restorative Dentistry and Biomaterials, and Director, Houston Biomaterials Research Center, University of Texas Dental Branch at Houston

College of Dentistry, Dental Research Institute, Seoul National University, Seoul, Republic of Korea; Houston Biomaterials Research Center, The University of Texas Dental Branch at Houston, Houston, Tex; Tokuyama Dental Corp, Tsukuba, Japan

Statement of problem

Generalized wear of composite resins in the noncontact area may result in changes of gloss, which can influence esthetics of restorations.

Purpose

The purpose of this study was to determine the changes in gloss of composite resins after generalized wear simulation. Surface roughness and amount of wear were measured for comparison.

Material and methods

Generalized wear simulation was performed with a wear tester for 400,000 cycles with 6 composite resins (Estelite Σ, Esthet X improved, Filtek Supreme, Heliomolar, Renamel Microfill, and Tetric-Ceram). Composite resin was placed into a mold (8 mm in diameter, 3 mm in depth) in an acrylic resin block, and 8 specimens were prepared per group. A flat-planed stylus made with polyacetal was loaded perpendicularly. Gloss was measured after every 100,000 cycles with a glossmeter in gloss units (GU). Average surface roughness (Ra) of each specimen before and after 400,000 cycles of wear was determined. The amount of wear was measured with a 3-dimensional profilometer. Changes in gloss were analyzed by repeated-measures analysis of variance, and mean values were compared by Fisher's PLSD interval (α=.05).

Results

Gloss was influenced by the number of wear cycles and the composite resin, and there was a significant interaction (P=.000) between the number of wear cycles and the brand of composite resin. There were no significant correlations between the wear depth and the gloss or changes in gloss after 400,000 cycles.

Conclusion

Generalized wear simulation for approximately 3 years of clinical use resulted in gloss changes of 36 to 64 GU, and maximum wear depth was in the range of 35 to 75 μm. Change in gloss varied among the composite resins, but average surface roughness was not influenced by the various composite resins.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 15.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0022-3913(05)00432-4

doi:10.1016/j.prosdent.2005.08.006

Journal of Prosthetic Dentistry
Volume 94, Issue 4 , Pages 370-376, October 2005