« Previous
Next »
Journal of Prosthetic Dentistry
Volume 94, Issue 5
, Pages 453-457
, November 2005
In vitro wear resistance of three types of composite resin denture teeth
References
- . In vitro wear of resin denture teeth. J Prosthet Dent. 1998;79:152–155
- . Quantitative evaluation of the wear resistance of posterior dental restorations: a new three-dimensional measuring technique. J Dent. 1984;12:252–267
- . Wear of materials used in dentistry: a review of the literature. J Prosthet Dent. 1990;63:342–349
- . Vertical height loss: an investigation of four restorative materials opposing enamel. J Prosthodont. 1999;8:252–257
- . Changes of masticatory movement characteristics after prosthodontic rehabilitation of individuals with extensive tooth wear. Int J Prosthodont. 1996;9:539–546
- . Morphologic and biochemical changes of the masseter muscles induced by occlusal wear: studies in a rat model. J Dent Res. 1999;78:1735–1744
- . Denture fracture—a survey. Br Dent J. 1994;176:342–345
- . An in vitro investigation of the wear of enamel on porcelain and gold in saliva. J Prosthet Dent. 1996;75:14–17
- . Clinical evaluation of composite resins as anterior and posterior restorative materials. J Prosthet Dent. 1975;33:407–416
- . Abrasive wear, tensile strength, and hardness of composite resins—is there a relationship?. J Prosthet Dent. 1976;36:395–398
- . A method for measuring the wear of restorative materials in vitro. Br Dent J. 1981;151:123–126
- . An in vitro study of high-strength resin posterior denture tooth wear. Int J Prosthodont. 1997;10:28–34
- . Clinical wear study of three commercially available artificial materials: thirty-six month results. J Prosthet Dent. 1998;79:145–151
- . An in vitro wear study of posterior denture tooth materials on human enamel. J Oral Rehabil. 2001;28:407–412
- . Microstructure of posterior restorations of composite resins after clinical wear. Oper Dent. 1980;5:90–94
- . Observation and comparison of polished composite surfaces with the aid of SEM and profilometer. J Oral Rehabil. 1982;9:169–182
- . Relationship between subsurface damage and wear of dental restorative composites. J Dent Res. 1982;61:1083–1088
- . In vitro wear assessment of titanium alloy teeth. J Prosthodont. 2002;11:263–269
- Wear resistance of experimental Ti-Cu alloys. Biomaterials. 2003;24:3377–3381
CONTRIBUTING AUTHORS Dongxiang Zheng, DDS, Associate Professor, Department of Prosthodontics, Faculty of Stomatology, Capital University of Medical Sciences, Beijing, China, and Zhenting Zhang, DDS, Professor, Department of Prosthodontics, Faculty of Stomatology, Capital University of Medical Sciences, Beijing, China.
PII: S0022-3913(05)00436-1
doi: 10.1016/j.prosdent.2005.08.010
© 2005 The Editorial Council of The Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Journal of Prosthetic Dentistry
Volume 94, Issue 5
, Pages 453-457
, November 2005