Journal of Prosthetic Dentistry
Volume 104, Issue 1 , Pages 48-55 , July 2010

Virtual variation simulation of CAD/CAM template-guided surgeries performed on human cadavers: Part II

  • Timo Kero, MSc

      Affiliations

    • PhD student, Department of Product and Production Development, Chalmers University of Technology, Göteborg, Sweden
    • Corresponding Author InformationCorresponding author: Mr Timo Kero, Chalmers University of Technology, Department of Product and Production Development, Division of Product Development, Hörsalsvägen 7A, SE-412 96 Göteborg, SWEDEN, Fax: +46 31 772 13 75
  • ,
  • Andreas Pettersson, BSc

      Affiliations

    • PhD student, Section for Image and Functional Odontology, Department of Dental Medicine, Karolinska Institute, Huddinge, Sweden; University Paris
  • ,
  • Jenny Fäldt, PhD

      Affiliations

    • Senior Scientist, Division of Early Development, Nobel Biocare AB, Göteborg, Sweden
  • ,
  • Matts Andersson, PhD

      Affiliations

    • Head, Division of Early Development, Nobel Biocare AB, Göteborg, Sweden
  • ,
  • Luc Gillot, DDS

      Affiliations

    • Clinical Instructor, Laboratory of Anatomy, Odontological Faculty, University Paris Descartes, Descartes, Paris, France
  • ,
  • Bernard Cannas, DDS

      Affiliations

    • Clinical Instructor, Laboratory of Anatomy, Odontological Faculty, University Paris Descartes, Descartes, Paris, France
  • ,
  • Karin Näsström, PhD

      Affiliations

    • Department Chair, Section for Image and Functional Odontology, Department of Dental Medicine, Karolinska Institute, Huddinge, Sweden; University Paris
  • ,
  • Rikard Söderberg, PhD

      Affiliations

    • Professor, Head of Department of Product and Production Development, and Director, Wingquist Laboratory, Chalmers University of Technology, Göteborg, Sweden

References 

  1. Marchack CB . An immediately loaded CAD/CAM-guided definitive prosthesis: a clinical report . J Prosthet Dent . 2005;93:8–12
  2. Widmann G . Image-guided surgery and medical robotics in the cranial area . Biomed Imaging Interv J . 2007;3:e11
  3. Schep NW , Broeders IA , van der Werkens C . Computer assisted orthopaedic and trauma surgery. State of the art and future perspectives . Injury . 2003;34:299–306
  4. Cleary K , Nguyen C . State of the art in surgical robotics: clinical applications and technology challenges . Comput Aid Surg . 2001;6:312–328
  5. Mack MJ . Minimally invasive and robotic surgery . J Am Med Assoc . 2001;285:568–572
  6. Hieu LC , Zlatov N , Vander Zloten J , Bohez E , Khanh L , Binh PH , et al.   Medical rapid prototyping applications and methods . Assembly Autom . 2005;25:284–292
  7. Schep NW , Broeders IA , van der Werken C . Computer assisted orthopaedic and trauma surgery: state of the art and future perspectives . Int J Care Injured . 2003;34:299–306
  8. van Steenberghe D , Glauser R , Blombäck U , Andersson M , Schutyser F , Pettersson A , et al.   A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study . Clin Implant Dent Relat Res . 2005;7(Suppl 1):S111–S120
  9. Vercruyssen M , Jacobs R , Van Assche N , van Steenberghe D . The use of CT scan based planning for oral rehabilitation by means of implants and its transfer to the surgical field: a critical review on accuracy . J Oral Rehabil . 2008;6:454–474
  10. Strub JR , Rekow ED , Witkowski S . Computer-aided design and fabrication of dental restorations: current systems and future possibilities . J Am Dent Assoc . 2006;1289–1296
  11. Truscott M , de Beer D , Vicatos G , Hosking K , Barnard L , Booysen G , et al.   Using RP to promote collaborative design of customized medical implants . Rapid Prototyping J . 2007;13:107–114
  12. Winder J , Bibb R . Medical rapid prototyping technologies: state of the art and current limitations for application in oral and maxillofacial surgery . J Oral Maxillofac Surg . 2005;1006–1015
  13. Söderberg R , Lindkvist L , Carlson J . Managing physical dependencies through location system design . J Eng Design . 2006;17:325–346
  14. Chase KW , Parkinson AR . A survey of research in the application of tolerance analysis to the design of mechanical assemblies . Res Eng Design . 1991;3:23–37
  15. Kim S , Nicholls JI , Han CH , Lee KW . Displacement of implant components from impressions to definitive casts . Int J Oral Maxillofac Implants . 2006;5:747–755
  16. Kumar S , Raman S . Computer-aided tolerancing: the past, the present and the future . J Des Manuf . 1992;2:29–41
  17. Abu-Hammad O , Khraisat A , Dar-Odeh N , Jagger DC , Hammerle CH . The staggered installation of dental implants and its effect on bone stresses . Clin Implant Dent Relat Res . 2007;9:121–127
  18. Kero T , Söderberg R , Andersson M , Lindkvist L . Process optimization regarding geometrical variation and sensitivity involving dental drill- and implant-guided surgeries . Int J Biol Life Sci . 2006;2:237–243
  19. Pettersson A , Kero T , Gillot L , Cannas B , Fäldt J , Söderberg R , et al.   Accuracy of CAD/CAM-guided surgical template implant surgery on human cadavers: Part I . J Prosthet Dent . 2010;

PII: S0022-3913(10)60089-3

doi: 10.1016/S0022-3913(10)60089-3

Journal of Prosthetic Dentistry
Volume 104, Issue 1 , Pages 48-55 , July 2010