Advertisement
Journal of Prosthetic Dentistry
Research Article| Volume 88, ISSUE 1, P26-31, July 2002

Delayed linear expansion of improved dental stone

      Abstract

      Statement of Problem. Specification 25 of the American Dental Association (ADA) states that final setting expansion measurements of improved dental stone are made 2 hours after mixing. In a limited pilot study on selected type IV and V dental stones, measurements showed delayed linear expansion or early contraction continuing up to 120 hours. Purpose. The objectives of this in vitro study were to measure the linear setting expansion of 6 ADA type IV and V dental stones, to compare their expansion at 2 hours relative to ADA Specification 25, and to characterize expansion changes up to 120 hours. Material and Methods. The improved dental stones tested in this study were Die-Keen, Jade Stone, Vel-Mix, ResinRock, Fuji Rock, and Silky Rock. Mixing was performed in accordance with a standardized technique and the manufacturers' instructions. The mixes were poured into an electronic expansion-measuring device, and setting expansion values were continuously measured and recorded for 120 hours. The collected data were subjected to a 2-way repeated-measures multivariate analysis of variance at α=.05. Planned comparisons between the 2-hour experimental and 2-hour manufacturer expansion values were made at the 95% confidence interval. Results. All stones showed higher mean linear expansion values at 120 hours than at 2 hours. Expansion was essentially complete at 96 hours for all stones except ResinRock. Die-Keen exhibited the highest total mean setting expansion (0.35% ± 0.013%), and Silky Rock exhibited the lowest mean linear expansion (0.14% ± 0.008%) at 120 hours. Multivariate analysis of variance revealed significant interactions between stone and time (P<.0001). Mean expansion values at 2 hours were comparable to those stated by the manufacturer except for Die-Keen and Jade Stone. Conclusion. Within the parameters of this study, all dental stones tested exhibited continued expansion while setting under clinical conditions. The amount of expansion varied significantly among the materials, with 22% to 71% of the expansion occurring after 2 hours. Die-Keen exhibited the highest total mean expansion but had the least amount of expansion after 2 hours; both Die-Keen and Silky Rock remained stable after 72 hours. (J Prosthet Dent 2002;88:26-31.)
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Journal of Prosthetic Dentistry
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Bailey JH
        • Donovan TE
        • Preston JD.
        The dimensional accuracy of improved dental stone silverplated, and epoxy resin die materials.
        J Prosthet Dent. 1988; 59: 307-310
        • American National Standards/American Dental Association
        Specification 25 for dental gypsum products.
        in: : American National Standards Institute, New York2000: 244-253
        • Mahler DB
        • Andy AB.
        Explanation for the hygroscopic setting expansion of dental gypsum products.
        J Dent Res. 1960; 39: 578-582
        • Aiach D
        • Malone WF
        • Sandrik J.
        Dimensional accuracy of epoxy resins and their compatibility with impression materials.
        J Prosthet Dent. 1984; 52: 500-504
        • Anusavice KJ.
        Phillip's science of dental materials.
        in: 10th ed. : WB Saunders, Philadelphia1996: 185-208
        • Peyton FA
        • Liebold JP
        • Ridgley GV.
        Surface hardness, compressive strength, and abrasion resistance of indirect die stones.
        J Prosthet Dent. 1952; 2: 381-389
        • International Standards Organization (ISO)
        International Standard 6873, dental gypsum products.
        : International Organization for Standardization, Geneva1998
        • Newman A
        • Williams JD.
        Die materials for inlay, crown and bridge work.
        Br Dent J. 1969; 127: 415-420
        • Winkler MM
        • Monaghan P
        • Gilbert JL
        • Lautenschlager EP.
        Comparison of four techniques for monitoring the setting kinetics of gypsum.
        J Prosthet Dent. 1998; 79: 532-536
        • Fernandes CP
        • Vassilakos N.
        Accuracy, detail reproduction, and hardness of gypsum casts produced from silicon impressions treated with glow discharge.
        J Prosthet Dent. 1993; 70: 457-464
        • Dilts W
        • Podshadley A
        • Ellison E
        • Neiman R.
        Accuracy of a removable die-dowel pin technique.
        J Dent Res. 1971; 50: 1249-1252
        • Schnieder RL
        • Taylor TD.
        Compressive strength and surface hardness of type IV die stone when mixed with water substitutes.
        J Prosthet Dent. 1984; 52: 510-514
        • Dilts WE
        • Podshadley AG
        • Sawyer HF
        • Neiman R.
        Accuracy of four removable die techniques.
        J Am Dent Assoc. 1971; 83: 1081-1085
        • Buchman AS
        • Worner HK.
        Changes in the composition and setting characteristics of plaster of Paris on exposure to high humidity atmospheres.
        J Dent Res. 1945; 24: 65-74
        • Combe EC
        • Smith DC.
        Studies on the preparation of calcium sulfate hemihydrate by an autoclave process.
        J App Chem. 1968; 18: 307-312
        • Cohen J.
        New die materials in dentistry.
        J Mich Dent Assoc. 1962; 44: 9-13
        • McCabe JF.
        Applied dental materials.
        in: 7th ed. : Martin Book Service Ltd, London1990: 28-31
        • Hoggat G.
        Method of producing gypsum plaster.
        US Patent. 1933; 3: 190105
        • Earnhurst R
        • Marks BI.
        The measurement of the setting time of gypsum products.
        Aust Dent J. 1964; 9: 17-26
        • Budnikov P.
        Activating and retarding agents for the setting of plaster of Paris.
        Kolloid Z. 1928; 44: 242-249
        • Chaffee NR
        • Bailey JH
        • Sherrard DJ.
        Dimensional accuracy of improved dental stone and epoxy resin die materials. Part I: Single die.
        J Prosthet Dent. 1997; 77: 131-135
        • Yli-Urpo A
        • Oilo G
        • Syverud M.
        The effect of asbestos-alternatives on the accuracy of cast veneer crowns.
        Swed Dent J. 1982; 6: 127-131
        • Derrien G
        • Le Menn G.
        Evaluation of detail reproduction for three die materials by using scanning electron microscopy and two-dimensional profilometry.
        J Prosthet Dent. 1995; 74: 1-7
        • Schwedhelm ER
        • Lepe X.
        Fracture strength of type IV and type V die stone as a function of time.
        J Prosthet Dent. 1997; 78: 554-559
        • Gerrow JD
        • Price RB.
        Comparison of the surface detail reproduction of flexible die material systems.
        J Prosthet Dent. 1998; 80: 485-489
        • Alsadi S
        • Combe EC
        • Cheng YS.
        Properties of gypsum with the addition of gum arabic and calcium hydroxide.
        J Prosthet Dent. 1996; 76: 530-534
        • Derrien G
        • Sturtz G.
        Comparison of transverse strength and dimensional variations between die stone, die epoxy resin, and die polyurethane resin.
        J Prosthet Dent. 1995; 74: 569-574
        • Chaffee NR
        • Bailey JH
        • Sherrard DJ.
        Dimensional accuracy of improved dental stone and epoxy resin die materials. Part II: Complete arch form.
        J Prosthet Dent. 1997; 77: 235-238