Advertisement
Journal of Prosthetic Dentistry
Research Article| Volume 88, ISSUE 2, P159-169, August 2002

Influence of cold working and thermal treatment on the fit of implant-supported metal-ceramic fixed partial dentures

      Abstract

      Statement of Problem. The application of porcelain may alter the fit of metal-ceramic frameworks. In fixed partial denture frameworks, this altered fit may cause marginal opening and require sectioning and soldering of the prosthesis. Purpose. The purpose of this study was to compare the fit of implant-supported metal-ceramic fixed partial dentures when different thermal treatments were performed. Material and Methods. Fifteen implant-supported metal-ceramic fixed partial denture frameworks were fabricated and divided into 3 treatment groups: Group 1 = cold working and thermal oxidation; Group 2 = unrestrained thermal treatment, cold working, and oxidation; and Group 3 = investment-restrained thermal treatment, cold working, and oxidation. After the appropriate treatment procedures, porcelain was applied. Measurements were made with a digital caliper, with the help of fiduciary marks, after each step in 3 dimensions and at 2 locations. These measurements were compared with those of the as-cast framework (baseline) to determine framework distortion. Distortion data among groups were compared with repeated-measures analysis of variance and Tukey's Studentized range test (P<.05). Results. Absolute values of distortion (regardless of direction) after thermal treatment and after porcelain application were not significantly different among groups. However, total raw values of distortion, which describe the specific direction of distortion, were significantly different for 4 of the 6 recorded measurements between Groups 1 and 3 (P<.05). Although the absolute distortion values did not differ among groups, heat treatment and finishing of the alloy affected the timing and direction of distortion. Conclusion. Within the limitations of this study, heat treatment of implant-supported metal-ceramic fixed partial denture frameworks before cold working did not decrease the total absolute distortion. Definite patterns of distortion were, however, found in Groups 1 and 3, suggesting that specific manipulations and heat treatments of the alloy affected the direction of distortion. (J Prosthet Dent 2002;88:159-69.)
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Journal of Prosthetic Dentistry
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Adell R
        • Eriksson B
        • Lekholm U
        • Branemark PI
        • Jemt T.
        A long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws.
        Int J Oral Maxillofac Implants. 1990; 5: 347-359
        • van Steenberghe D
        • Lekholm U
        • Bolender C
        • Folmer T
        • Henry P
        • Herrmann I
        • et al.
        Applicability of osseointegrated oral implants in the rehabilitation of partial edentulism: a prospective multicenter study on 558 fixtures.
        Int J Oral Maxillofac Implants. 1990; 5: 272-281
        • Gunne J
        • Astrand P
        • Ahlen K
        • Borg K
        • Olsson M.
        Implants in partially edentulous patients. A longitudinal study of bridges supported by both implants and natural teeth.
        Clin Oral Implants Res. 1992; 3: 49-56
        • Zarb GA
        • Schmitt A.
        The longitudinal clinical effectiveness of osseointegrated dental implants in posterior partially edentulous patients.
        Int J Prosthodont. 1993; 6: 189-196
        • Jemt T
        • Lekholm U.
        Oral implant treatment in posterior partially edentulous jaws: a 5-year follow-up report.
        Int J Oral Maxillofac Implants. 1993; 8: 635-640
        • Schmitt A
        • Zarb GA.
        The longitudinal clinical effectiveness of osseointegrated dental implants for single-tooth replacement.
        Int J Prosthodont. 1993; 6: 197-202
        • Jemt T
        • Pettersson P.
        A 3-year follow-up study on single implant treatment.
        J Dent. 1993; 21: 203-208
        • Jemt T
        • Lekholm U
        • Grondahl K.
        3-year follow-up study of early single implant restorations ad modum Branemark.
        Int J Periodontics Restorative Dent. 1990; 10: 340-349
        • Laney WR
        • Jemt T
        • Harris D
        • Henry PJ
        • Krogh PH
        • Polizzi G
        • et al.
        Osseointegrated implants for single-tooth replacement: progress report from a multicenter prospective study after 3 years.
        Int J Oral Maxillofac Implants. 1994; 9: 49-54
        • Kallus T
        • Bessing C.
        Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years.
        Int J Oral Maxillofac Implants. 1994; 9: 169-178
      1. Tissue-integrated prostheses: osseointegration in clinical dentistry. : Quintessence, Chicago1988: 175
        • Zarb GA
        • Symington JM.
        Osseointegrated dental implants: preliminary report on a replication study.
        J Prosthet Dent. 1983; 50: 271-276
        • Laney WR
        • Tolman DE
        • Keller EE
        • Desjardins RP
        • Van Roekel NB
        • Branemark PI.
        Dental implants: tissue-integrated prosthesis utilizing the osseointegration concept.
        Mayo Clin Proc. 1986; 61: 91-97
        • Worthington P
        • Bolender CL
        • Taylor TD.
        The Swedish system of osseointegrated implants: problems and complications encountered during a 4-year trial period.
        Int J Oral Maxillofac Implants. 1987; 2: 77-84
        • Sones AD.
        Complications with osseointegrated implants.
        J Prosthet Dent. 1989; 62: 581-585
        • Carr AB
        • Gerard DA
        • Larsen PE.
        The response of bone in primates around unloaded dental implants supporting prostheses with different levels of fit.
        J Prosthet Dent. 1996; 76: 500-509
        • Michaels GC
        • Carr AB
        • Larsen PE.
        Effect of prosthetic superstructure accuracy on the osteointegrated implant bone interface.
        Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1997; 83: 198-205
        • Jemt T
        • Book K.
        Prosthesis misfit and marginal bone loss in edentulous implant patients.
        Int J Oral Maxillofac Implants. 1996; 11: 620-625
        • Wicks RA
        • deRijk WG
        • Windeler SA.
        An evaluation of fit in osseointegrated implant components using torque/turn analysis.
        J Prosthodont. 1994; 3: 206-212
        • Kan JY
        • Rungcharassaeng K
        • Bohsali K
        • Goodacre CJ
        • Lang BR.
        Clinical methods for evaluating implant framework fit.
        J Prosthet Dent. 1999; 81: 7-13
        • Mumford G.
        The porcelain-fused-to-metal restoration.
        Dent Clin North Am. 1965; 2: 241-249
        • Silver M
        • Klein G
        • Howard MC.
        An evaluation and comparison of porcelain fused to cast metals.
        J Prosthet Dent. 1960; 10: 1055-1064
        • Faucher RR
        • Nicholls JI.
        Distortion related to margin design in porcelain-fused-to-metal restorations.
        J Prosthet Dent. 1980; 43: 149-155
        • Shillingburg Jr, HT
        • Hobo S
        • Fisher DW.
        Preparation design and margin distortion in porcelain-fused-to-metal restorations.
        J Prosthet Dent. 1973; 29: 276-284
        • Bridger DV
        • Nicholls JI.
        Distortion of ceramometal fixed partial dentures during the firing cycle.
        J Prosthet Dent. 1981; 45: 507-514
        • Buchanan WT
        • Svare CW
        • Turner KA.
        The effect of repeated firings and strength on marginal distortion in two ceramometal systems.
        J Prosthet Dent. 1981; 45: 502-506
        • DeHoff PH
        • Anusavice KJ.
        Effect of metal design on marginal distortion of metal-ceramic crowns.
        J Dent Res. 1984; 63: 1327-1331
        • Richter-Snapp K
        • Aquilino SA
        • Svare CW
        • Turner KA.
        Change in marginal fit as related to margin design, alloy type, and porcelain proximity in porcelain-fused-to-metal restorations.
        J Prosthet Dent. 1988; 60: 435-439
        • Belser UC
        • MacEntee MI
        • Richter WA.
        Fit of three porcelain-fused-to-metal marginal designs in vivo: a scanning electron microscope study.
        J Prosthet Dent. 1985; 53: 24-29
        • Shelby DS.
        Practical considerations and design of porcelain fused to metal.
        J Prosthet Dent. 1962; 12: 542-548
        • Pascoe DF.
        Analysis of the geometry of finishing lines for full crown restorations.
        J Prosthet Dent. 1978; 40: 157-162
        • Strating H
        • Pameijer CH
        • Gildenhuys RR.
        Evaluation of the marginal integrity of ceramometal restorations. Part I.
        J Prosthet Dent. 1981; 46: 59-65
        • Campbell SD
        • Pelletier LB.
        Thermal cycling distortion of metal ceramics: Part I--Metal collar width.
        J Prosthet Dent. 1992; 67: 603-608
        • Campbell SD
        • Pelletier LB.
        Thermal cycling distortion of metal ceramics. Part II--Etiology.
        J Prosthet Dent. 1992; 68: 284-289
        • Campbell SD
        • Sirakian A
        • Pelletier LB
        • Giordano RA.
        Effects of firing cycle and surface finishing on distortion of metal ceramic castings.
        J Prosthet Dent. 1995; 74: 476-481
        • Yamamoto M.
        Metal-ceramics. Principles and methods of Makoto Yamamoto.
        in: : Quintessence, Chicago1985: 203-218
        • Felton DA
        • Sulik WD
        • Holland GA
        • Taylor DF
        • Bayne SC.
        Marginal discrepancy changes at various stages of construction of three-unit porcelain-fused-to-metal fixed partial dentures.
        Dent Mater. 1988; 4: 296-301
        • Gemalmaz D
        • Alkumru HN.
        Marginal fit changes during porcelain firing cycles.
        J Prosthet Dent. 1995; 73: 49-54
        • Gemalmaz D
        • Berksun S
        • Kasapoglu Ç
        • Alkumru NH.
        Distortion of metal-ceramic fixed partial dentures resulting from metal-conditioning firing.
        Quintessence Int. 1996; 27: 193-201
        • Gemalmaz D
        • Berksun S
        • Alkumru NH
        • Kasapoglu Ç
        Thermal cycling distortion of porcelain fused to metal fixed partial dentures.
        J Prosthet Dent. 1998; 80: 654-660
        • Zervas PJ
        • Papazoglou E
        • Beck FM
        • Carr AB.
        Distortion of three-unit implant frameworks during casting, soldering, and simulated porcelain firings.
        J Prosthodont. 1999; 8: 171-179
        • Earnshaw R
        • Morey EF
        • Edelman DC.
        The effect of potential investment expansion and hot strength on the fit of full crown castings made with phosphate-bonded investment.
        J Oral Rehabil. 1997; 24: 532-539
        • Luk HW
        • Darvell BW.
        Strength of phosphate-bonded investments at high temperature.
        Dent Mater. 1991; 7: 99-102
        • Binon PP.
        Evaluation of machining accuracy and consistency of selected implants, standard abutments, and laboratory analogs.
        Int J Prosthodont. 1995; 8: 162-178