Advertisement
Journal of Prosthetic Dentistry
Research Article| Volume 112, ISSUE 4, P770-777, October 2014

Clinical outcomes of three different crown systems with CAD/CAM technology

      Statement of problem

      Computer-aided design and computer-aided manufacturing (CAD/CAM) generated restorations are gaining popularity. However, limited clinical evidence is available for single-unit posterior CAD/CAM restorations fabricated with established and newer crown materials.

      Purpose

      The purpose of this clinical study was to assess the restoration quality of and gingival response to CAD/CAM fabricated posterior single-tooth restorations with different processing technologies.

      Material and methods

      Twenty-two individuals in need of posterior complete coverage crowns were recruited under an institutional review board approved protocol. Teeth were randomized to 1 of 3 groups: metal ceramic, lithium disilicate, and monolithic zirconia. An unprepared or minimally restored tooth on the contralateral side was chosen as a control tooth for gingival measurements with each participant. Teeth were prepared and scanned intraorally by 1 of 3 experienced practitioners. A total of 32 restorations were digitally designed and fabricated with either milling technology or rapid-prototype printing and casting with conventional porcelain application. Restorations were evaluated with modified United States Public Health Service criteria for contour, marginal adaptation, occlusion, and shade. Gingival crevicular fluid volume and bleeding on probing were recorded preoperatively, at 1-month and 6-month postcementation visits. Polyvinyl siloxane impressions were made of the buccal margin of cemented restorations and evaluated with microcomputed tomography to assess marginal adaptation (horizontal discrepancy). The Mantel Haenszel row mean score was used to assess whether the crown systems differed with respect to the modified United States Public Health Service criteria. Linear mixed models were used to assess whether the average gingival volumes were affected by the explanatory variables (crown system, tooth status [treated vs control], or visit). A generalized estimating equation approach was used to assess whether bleeding on probing was affected by the explanatory variables. One-way ANOVA was used to assess marginal discrepancy values among the crown systems (α=.05 for all tests).

      Results

      Twelve metal ceramic, 10 lithium disilicate, and 10 zirconia restorations were fabricated for 22 participants. Zirconia restorations were significantly different from the other 2 crown systems (P<.001) with respect to occlusion. No occlusal adjustment was needed on 80% of the zirconia restorations. The average gingival crevicular fluid volumes did not differ among crown systems, between treated and control groups, or over time. The average horizontal marginal discrepancy was significantly different between lithium disilicate and zirconia crowns (P=.027), with zirconia crowns having the least amount of horizontal marginal discrepancy.

      Conclusions

      Given the small sample size and limitations of this study, CAD/CAM-generated restorations for posterior teeth made from different materials had acceptable clinical results.
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Journal of Prosthetic Dentistry
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

      1. U.S. Dental Prosthetics and CAD/CAM Devices Market. iData Research Inc. 2011. Available at: www.idataresearch.com. Last accessed June 12, 2014.

        • Hamza T.A.
        • Ezzat H.A.
        • El-Hossary M.M.
        • Katamish H.A.
        • Shokry T.E.
        • Rosenstiel S.F.
        Accuracy of ceramic restorations made with two CAD/CAM systems.
        J Prosthet Dent. 2013; 109: 83-87
        • Oliver-Parra R.
        Marginal adaptation of zirconium dioxide copings: influence of the CAD/CAM system and the finish line design.
        J Prosthet Dent. 2014; 112: 155-162
        • Miyazaki T.
        • Hotta Y.
        • Kunii J.
        • Kuriyama S.
        • Tamaki Y.
        A review of dental CAD/CAM: current status and future perspectives from 20 years of experience.
        Dent Mater J. 2009; 28: 44-56
        • da Costa J.B.
        • Pelogia F.
        • Hagedorn B.
        • Ferracane J.L.
        Evaluation of different methods of optical impression making on the marginal gap of onlays created with CEREC 3D.
        Oper Dent. 2010; 35: 324-329
        • Kokubo Y.
        • Tsumita M.
        • Sakurai S.
        • Suzuki Y.
        • Tokiniwa Y.
        • Fukushima S.
        Five-year clinical evaluation of In-Ceram crowns fabricated using GN-I (CAD/CAM) system.
        J Oral Rehabil. 2011; 38: 601-607
        • Güth J.F.
        • Keul C.
        • Stimmelmayr M.
        • Beuer F.
        • Edelhoff D.
        Accuracy of digital models obtained by direct and indirect data capturing.
        Clin Oral Invest. 2013; 17: 1201-1208
        • Biscaro L.
        • Bonfiglioli R.
        • Soattin M.
        • Vigolo P.
        An in vivo evaluation of fit of zirconium-oxide based ceramic single crowns, generated with two CAD/CAM systems, in comparison to metal ceramic single crowns.
        J Prosthodont. 2013; 22: 36-41
        • Syrek A.
        • Reich G.
        • Ranftl D.
        • Klein C.
        • Cerny B.
        • Brodesser J.
        Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling.
        J Dent. 2010; 38: 553-559
      2. Baig M, Tan K, Nicholls J. Evaluation of the marginal fit of a zirconia ceramic computer-aided machined (CAM) crown system. J Prosthet Dent 2010;104:216.

      3. Brawek P, Wolfart S, Endres L, Kirsten A, Reich S. The clinical accuracy of single crowns exclusively fabricated by digital workflow: the comparison of two systems. Clin Oral Investig 2013;17:2119–225.

        • Gehrt M.
        • Wolfart S.
        • Rafai N.
        • Reich S.
        • Edelhoff D.
        Clinical results of lithium-disilicate crowns after up to 9 years of service.
        Clin Oral Invest. 2013; 17: 275-284
        • Fasbinder D.
        • Dennison J.
        • Heys D.
        • Neiva G.
        A clinical evaluation of chairside lithium disilicate CAD/CAM crowns: a two-year report.
        J Am Dent Assoc. 2010; 141: 10S-4
        • Sailer I.
        • Feher A.
        • Filser F.
        • Gauckler L.
        • Luthy H.
        • Hämmerle C.
        Five-year clinical results of zirconia frameworks for posterior fixed partial dentures.
        Int J Prosthodont. 2007; 20: 383-388
        • Raigrodski A.J.
        • Chiche G.J.
        • Potiket N.
        • Hochstedler J.L.
        • Mohamed S.E.
        • Billiot S.
        • et al.
        The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study.
        J Prosthet Dent. 2006; 96: 237-244
        • Felton D.
        • Kanoy B.
        • Bayne S.
        • Wirthman B.
        Effect of in vivo crown margin discrepancies on periodontal health.
        J Prosthet Dent. 1991; 65: 357-364
        • Lang N.
        • Kiel R.
        • Anderhalden K.
        Clinical and microbiological effects of subgingival restorations with overhanging or clinically perfect margins.
        J Clin Periodontol. 1983; 6: 563-578
        • Pelaez J.
        • Cogolludo P.G.
        • Serrano B.
        • Serrano J.F.
        • Suarez M.J.
        A four-year prospective clinical evaluation of zirconia and metal-ceramic posterior fixed dental prostheses.
        Int J Prosthodont. 2012; 25: 451-458
        • Nawafleh N.A.
        • Mack F.
        • Evans J.
        • Mackay J.
        • Hatamleh M.M.
        Accuracy and reliability of methods to measure marginal adaptation of crowns and FDPs: a literature review.
        J Prosthodont. 2013; 22: 419-428
        • Renne W.
        • McGill S.
        • Forshee K.
        • DeFee M.
        • Mennito A.
        Predicting marginal fit of CAD/CAM crowns based on the presence or absence of common preparation errors.
        J Prosthet Dent. 2012; 108: 310-315
        • Grenade C.
        • Mainjot A.
        • Vanheusden A.
        Fit of single tooth zirconia copings: comparison between various manufacturing processes.
        J Prosthet Dent. 2011; 105: 249-255
        • Matta R.
        • Schmitt J.
        • Wichmann M.
        • Holst S.
        Circumferential fit assessment of CAD/CAM single crowns: a pilot investigation on a new virtual analytical protocol.
        Quintessence Int. 2012; 43: 801-809