Effect of repeated ceramic firings on the marginal and internal adaptation of metal-ceramic restorations fabricated with different CAD-CAM technologies

      Abstract

      Statement of problem

      The use of computer-aided design and computer-aided manufacturing (CAD-CAM) for metal-ceramic restorations has increased with advances in the technology. However, little is known about the marginal and internal adaptation of restorations fabricated using laser sintering (LS) and soft milling (SM). Moreover, the effects of repeated ceramic firings on the marginal and internal adaptation of metal-ceramic restorations fabricated with LS and SM is also unknown.

      Purpose

      The purpose of this in vitro study was to investigate the effects of repeated ceramic firings on the marginal and internal adaptation of metal-ceramic copings fabricated using the lost wax (LW), LS, and SM techniques.

      Material and methods

      Ten LW, 10 LS, and 10 SM cobalt-chromium (Co-Cr) copings were fabricated for an artificial tooth (Frasaco GmbH). After the application of veneering ceramic (VITA VMK Master; VITA Zahnfabrik), the marginal and internal discrepancies of these copings were measured with a silicone indicator paste and a stereomicroscope at ×100 magnification after the first, second, and third clinical simulated ceramic firing cycles. Repeated measures 2-way ANOVA and the Fisher LSD post hoc test were used to evaluate differences in marginal and internal discrepancies (α=.05).

      Results

      Neither fabrication protocol nor repeated ceramic firings had any statistically significant effect on internal discrepancy values (P>.05). Marginal discrepancy values were also statistically unaffected by repeated ceramic firings (P>.05); however, the fabrication protocol had a significant effect on marginal discrepancy values (P<.001), with LW resulting in higher marginal discrepancy values than LS or SM (P<.05). Marginal discrepancy values did not vary between LS and SM (P>.05).

      Conclusions

      All groups demonstrated clinically acceptable marginal adaptation after repeated ceramic firing cycles; however, the LS and SM groups demonstrated better marginal adaptation than that of LW group and may be appropriate clinical alternatives to LW.
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Journal of Prosthetic Dentistry
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Kelly J.R.
        • Rose T.C.
        Nonprecious alloys for use in fixed prosthodontics: a literature review.
        J Prosthet Dent. 1983; 49: 363-370
        • Wataha J.C.
        Alloys for prosthodontic restorations.
        J Prosthet Dent. 2002; 87: 351-363
        • Khamis E.
        • Seddik M.
        Corrosion evaluation of recasting non-precious dental alloys.
        Int Dent J. 1995; 45: 209-217
        • Wassell R.W.
        • Walls A.W.
        • Steele J.G.
        Crowns and extra-coronal restorations: materials selection.
        Br Dent J. 2002; 192 (205-11): 199-202
        • Kim K.B.
        • Kim J.H.
        • Kim W.C.
        • Kim H.Y.
        • Kim J.H.
        Evaluation of the marginal and internal gap of metal-ceramic crown fabricated with a selective laser sintering technology: two- and three-dimensional replica techniques.
        J Adv Prosthodont. 2013; 5: 179-186
        • Huang Z.
        • Zhang L.
        • Zhu J.
        • Zhang X.
        Clinical marginal and internal fit of metal ceramic crowns fabricated with a selective laser melting technology.
        J Prosthet Dent. 2015; 113: 623-627
        • Suleiman S.H.
        • Vult von Steyern P.
        Fracture strength of porcelain fused to metal crowns made of cast, milled or laser-sintered cobalt-chromium.
        Acta Odontol Scand. 2013; 71: 1280-1289
        • Nesse H.
        • Ulstein D.M.
        • Vaage M.M.
        • Oilo M.
        Internal and marginal fit of cobalt-chromium fixed dental prostheses fabricated with 3 different techniques.
        J Prosthet Dent. 2015; 114: 686-692
        • Huang Z.
        • Zhang L.
        • Zhu J.
        • Zhao Y.
        • Zhang X.
        Clinical marginal and internal fit of crowns fabricated using different CAD/CAM Technologies.
        J Prosthodont. 2015; 24: 291-295
        • Ortorp A.
        • Jonsson D.
        • Mouhsen A.
        • Vult von Steyern P.
        The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: a comparative in vitro study.
        Dent Mater. 2011; 27: 356-363
        • Kane L.M.
        • Chronaios D.
        • Sierraalta M.
        • George F.M.
        Marginal and internal adaptation of milled cobalt-chromium copings.
        J Prosthet Dent. 2015; 114: 680-685
        • Ucar Y.
        • Akova T.
        • Akyil M.S.
        • Brantley W.A.
        Internal fit evaluation of crowns prepared using a new dental crown fabrication technique: laser-sintered Co-Cr crowns.
        J Prosthet Dent. 2009; 102: 253-259
        • Kim K.B.
        • Kim W.C.
        • Kim H.Y.
        • Kim J.H.
        An evaluation of marginal fit of three-unit fixed dental prostheses fabricated by direct metal laser sintering system.
        Dent Mater. 2013; 29: 91-96
        • Kim K.B.
        • Kim J.H.
        • Kim W.C.
        • Kim J.H.
        Three-dimensional evaluation of gaps associated with fixed dental prostheses fabricated with new technologies.
        J Prosthet Dent. 2014; 112: 1432-1436
        • Quante K.
        • Ludwig K.
        • Kern M.
        Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology.
        Dent Mater. 2008; 24: 1311-1315
        • Sun J.
        • Zhang F.Q.
        The application of rapid prototyping in prosthodontics.
        J Prosthodont. 2012; 21: 641-644
        • Yang X.
        • Xiang N.
        • Wei B.
        Effect of fluoride content on ion release from cast and selective laser melting-processed Co-Cr-Mo alloys.
        J Prosthet Dent. 2014; 112: 1212-1216
        • Strub J.R.
        • Rekow E.D.
        • Witkowski S.
        Computer-aided design and fabrication of dental restorations: current systems and future possibilities.
        J Am Dent Assoc. 2006; 137: 1289-1296
        • Seker E.
        • Ozcelik T.B.
        • Rathi N.
        • Yilmaz B.
        Evaluation of marginal fit of CAD/CAM restorations fabricated through cone beam computerized tomography and laboratory scanner data.
        J Prosthet Dent. 2016; 115: 47-51
        • Colpani J.T.
        • Borba M.
        • Della Bona A.
        Evaluation of marginal and internal fit of ceramic crown copings.
        Dent Mater. 2013; 29: 174-180
        • Tamac E.
        • Toksavul S.
        • Toman M.
        Clinical marginal and internal adaptation of CAD/CAM milling, laser sintering, and cast metal ceramic crowns.
        J Prosthet Dent. 2014; 112: 909-913
        • Valderhaug J.
        • Birkeland J.M.
        Periodontal conditions in patients 5 years following insertion of fixed prostheses. Pocket depth and loss of attachment.
        J Oral Rehabil. 1976; 3: 237-243
        • Cooper T.M.
        • Christensen G.J.
        • Laswell H.R.
        • Baxter R.
        Effect of venting on cast gold full crowns.
        J Prosthet Dent. 1971; 26: 621-626
        • Karlsson S.
        A clinical evaluation of fixed bridges, 10 years following insertion.
        J Oral Rehabil. 1986; 13: 423-432
        • McLean J.W.
        • von Fraunhofer J.A.
        The estimation of cement film thickness by an in vivo technique.
        Br Dent J. 1971; 131: 107-111
        • Fransson B.
        • Oilo G.
        • Gjeitanger R.
        The fit of metal-ceramic crowns, a clinical study.
        Dent Mater. 1985; 1: 197-199
        • Kashani H.G.
        • Khera S.C.
        • Gulker I.A.
        The effects of bevel angulation on marginal integrity.
        J Am Dent Assoc. 1981; 103: 882-885
        • Zeng L.
        • Zhang Y.
        • Liu Z.
        • Wei B.
        Effects of repeated firing on the marginal accuracy of Co-Cr copings fabricated by selective laser melting.
        J Prosthet Dent. 2015; 113: 135-139
        • Fonseca J.C.
        • Henriques G.E.
        • Sobrinho L.C.
        • de Goes M.F.
        Stress-relieving and porcelain firing cycle influence on marginal fit of commercially pure titanium and titanium-aluminum-vanadium copings.
        Dent Mater. 2003; 19: 686-691
        • Hamaguchi H.
        • Cacciatore A.
        • Tueller V.M.
        Marginal distortion of the porcelain- bonded-to-metal complete crown: an SEM study.
        J Prosthet Dent. 1982; 47: 146-153
        • Valderrama S.
        • Van Roekel N.
        • Andersson M.
        • Goodacre C.J.
        • Munoz C.A.
        A comparison of the marginal and internal adaptation of titanium and gold-platinum-palladium metal ceramic crowns.
        Int J Prosthodont. 1995; 8: 29-37
        • Xu D.
        • Xiang N.
        • Wei B.
        The marginal fit of selective laser melting-fabricated metal crowns: an in vitro study.
        J Prosthet Dent. 2014; 112: 1437-1440
        • Goodacre C.J.
        • Campagni W.V.
        • Aquilino S.A.
        Tooth preparations for complete crowns: an art form based on scientific principles.
        J Prosthet Dent. 2001; 85: 363-376
        • Tidehag P.
        • Ottosson K.
        • Sjogren G.
        Accuracy of ceramic restorations made using an in-office optical scanning technique: an in vitro study.
        Oper Dent. 2014; 39: 308-316
        • Martínez-Rus F.
        • Suárez M.J.
        • Rivera B.
        • Pradíes G.
        Evaluation of the absolute marginal discrepancy of zirconia-based ceramic copings.
        J Prosthet Dent. 2011; 105: 108-114
        • Kocaağaoğlu H.
        • Kılınç H.İ.
        • Albayrak H.
        • Kara M.
        In vitro evaluation of marginal, axial, and occlusal discrepancies in metal ceramic restorations produced with new technologies.
        J Prosthet Dent. 2016; 116: 368-374