      Statement of problem

      Recent resin-based and ceramic-based computer-aided design and computer-aided manufacturing (CAD-CAM) materials have been used to restore endodontically treated teeth. Adaptation of the restoration is important for clinical success, but studies evaluating the effect of these materials on the adaptation of endocrowns are lacking.

      Purpose

      The purpose of this in vitro study was to evaluate the effect of resin-based and ceramic-based materials on the marginal and internal adaptation of endocrowns.

      Material and methods

      Forty mandibular molars were divided into 4 groups (n=10); each group was restored with a different CAD-CAM material: group C: hybrid nanoceramic (Cerasmart; GC Corp), group T: fiber-composite material (Trilor; Bioloren Srl), group E: lithium disilicate glass-ceramic (IPS e.max CAD; Ivoclar Vivadent AG), and group V: zirconia-reinforced lithium silicate glass-ceramic (Vita Suprinity; VITA Zahnfabrik GmbH). A digital scan was made with an intraoral digital scanner (TRIOS 3; 3Shape A/S), and endocrowns were milled with a 5-axis milling machine (Coritec 250i; imes-icore GmbH). The replica technique and a stereomicroscope (×70) were used to measure the marginal and internal adaptation of the endocrowns at 32 points. All data were statistically analyzed using 1-way ANOVA and the Tukey honestly significant difference test (α=.05).

      Results

      Statistical tests showed significant differences among the tested groups (P<.001). The resin-based groups displayed larger discrepancies than the ceramic-based groups. The resin-based groups showed a mean marginal gap larger than the mean internal gap C (P=.009), T (P<.001), whereas the ceramic-based groups showed similar gaps, V (P=.396), E (P=.936). The largest gap was observed at the pulpal floor (P<.001).

      Conclusions

      All materials had clinically acceptable internal and marginal gaps (≤150 μm), except for the marginal gap of the Trilor group.
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic and PersonalCorporate R&D Professionals
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Journal of Prosthetic Dentistry
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Belleflamme M.M.
        • Geerts S.O.
        • Louwette M.M.
        • Grenade C.F.
        • Vanheusden A.J.
        • Mainjot A.K.
        No post-no core approach to restore severely damaged posterior teeth: An up to 10-year retrospective study of documented endocrown cases.
        J Dent. 2017; 63: 1-7
        • Fages M.
        • Raynal J.
        • Tramini P.
        • Cuisinier F.J.
        • Durand J.C.
        Chairside computer-aided design/computer-aided manufacture all-ceramic crown and endocrown restorations: A 7-year survival rate study.
        Int J Prosthodont. 2017; 30: 556-560
        • Gulec L.
        • Ulusoy N.
        Effect of endocrown restorations with different CAD/CAM materials: 3D finite element and weibull analyses.
        Biomed Res Int. 2017; 2017: 5638683
        • Soares C.J.
        • Valdivia A.D.
        • da Silva G.R.
        • Santana F.R.
        • Menezes Mde S.
        Longitudinal clinical evaluation of post systems: A literature review.
        Braz Dent J. 2012; 23: 135-740
        • Bindl A.
        • Mormann W.H.
        Clinical evaluation of adhesively placed cerec endo-crowns after 2 years--preliminary results.
        J Adhes Dent. 1999; 1: 255-265
        • Pissis P.
        Fabrication of a metal-free ceramic restoration utilizing the monobloc technique.
        Pract Periodontics Aesthet Dent. 1995; 7: 83-94
        • Sedrez-Porto J.A.
        • Rosa W.L.
        • da Silva A.F.
        • Munchow E.A.
        • Pereira-Cenci T.
        Endocrown restorations: A systematic review and meta-analysis.
        J Dent. 2016; 52: 8-14
        • Helal M.A.
        • Wang Z.
        Biomechanical assessment of restored mandibular molar by endocrown in comparison to a glass fiber post-retained conventional crown: 3D finite element analysis.
        J Prosthodont. 25 Oct 2017; ([Epub ahead of print])https://doi.org/10.1111/jopr.12690
        • Felton D.A.
        • Kanoy B.E.
        • Bayne S.C.
        • Wirthman G.P.
        Effect of in vivo crown margin discrepancies on periodontal health.
        J Prosthet Dent. 1991; 65: 357-364
        • Zhang Y.
        • Kim J.W.
        • Bhowmick S.
        • Thompson V.P.
        • Rekow E.D.
        Competition of fracture mechanisms in monolithic dental ceramics: flat model systems.
        J Biomed Mater Res B Appl Biomater. 2009; 88: 402-411
        • Holmes J.R.
        • Bayne S.C.
        • Holland G.A.
        • Sulik W.D.
        Considerations in measurement of marginal fit.
        J Prosthet Dent. 1989; 62: 405-408
        • Shin Y.
        • Park S.
        • Park J.W.
        • Kim K.M.
        • Park Y.B.
        • Roh B.D.
        Evaluation of the marginal and internal discrepancies of CAD-CAM endocrowns with different cavity depths: An in vitro study.
        J Prosthet Dent. 2017; 117: 109-115
        • Gaintantzopoulou M.D.
        • El-Damanhoury H.M.
        Effect of preparation depth on the marginal and internal adaptation of computer-aided design/computer-assisted manufacture endocrowns.
        Oper Dent. 2016; 41: 607-616
        • Seo D.
        • Yi Y.
        • Roh B.
        The effect of preparation designs on the marginal and internal gaps in cerec3 partial ceramic crowns.
        J Dent. 2009; 37: 374-382
        • Yun M.J.
        • Jeon Y.C.
        • Jeong C.M.
        • Huh J.B.
        Comparison of the fit of cast gold crowns fabricated from the digital and the conventional impression techniques.
        J Adv Prosthodont. 2017; 9: 1-13
        • Kokubo Y.
        • Nagayama Y.
        • Tsumita M.
        • Ohkubo C.
        • Fukushima S.
        • Vult von Steyern P.
        Clinical marginal and internal gaps of in-ceram crowns fabricated using the GN-I system.
        J Oral Rehabil. 2005; 32: 753-758
        • Abduo J.
        • Lyons K.
        • Swain M.
        Fit of zirconia fixed partial denture: a systematic review.
        J Oral Rehabil. 2010; 37: 866-876
        • Groten M.
        • Axmann D.
        • Probster L.
        • Weber H.
        Determination of the minimum number of marginal gap measurements required for practical in-vitro testing.
        J Prosthet Dent. 2000; 83: 40-49
        • Boitelle P.
        • Mawussi B.
        • Tapie L.
        • Fromentin O.
        A systematic review of CAD/CAM fit restoration evaluations.
        J Oral Rehabil. 2014; 41: 853-874
        • Coldea A.
        • Swain M.V.
        • Thiel N.
        In-vitro strength degradation of dental ceramics and novel PICN material by sharp indentation.
        J Mech Behav Biomed Mater. 2013; 26: 34-42
        • Awada A.
        • Nathanson D.
        Mechanical properties of resin-ceramic CAD/CAM restorative materials.
        J Prosthet Dent. 2015; 114: 587-593
        • de Paula Silveira A.C.
        • Chaves S.B.
        • Hilgert L.A.
        • Ribeiro A.P.
        Marginal and internal fit of CAD-CAM-fabricated composite resin and ceramic crowns scanned by 2 intraoral cameras.
        J Prosthet Dent. 2017; 117: 386-392
        • Ramirez-Sebastia A.
        • Bortolotto T.
        • Roig M.
        • Krejci I.
        Composite vs ceramic computer-aided design/computer-assisted manufacturing crowns in endodontically treated teeth: analysis of marginal adaptation.
        Oper Dent. 2013; 38: 663-673
        • Malaguti G.
        • Rossi R.
        • Marziali B.
        • Esposito A.
        • Bruno G.
        • Dariol C.
        • et al.
        In vitro evaluation of prosthodontic impression on natural dentition: a comparison between traditional and digital techniques.
        Oral Implantol (Rome). 2016; 9: 21-27
        • Berrendero S.
        • Salido M.P.
        • Valverde A.
        • Ferreiroa A.
        • Pradies G.
        Influence of conventional and digital intraoral impressions on the fit of CAD/CAM-fabricated all-ceramic crowns.
        Clin Oral Investig. 2016; 20: 2403-2410
        • Nawafleh N.A.
        • Mack F.
        • Evans J.
        • Mackay J.
        • Hatamleh M.M.
        Accuracy and reliability of methods to measure marginal adaptation of crowns and FDPs: a literature review.
        J Prosthodont. 2013; 22: 419-428
        • Reich S.
        • Wichmann M.
        • Nkenke E.
        • Proeschel P.
        Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems.
        Eur J Oral Sci. 2005; 113: 174-179
        • Falk A.
        • Vult von Steyern P.
        • Fransson H.
        • Thoren M.M.
        Reliability of the impression replica technique.
        Int J Prosthodont. 2015; 28: 179-180
        • Rahme H.Y.
        • Tehini G.E.
        • Adib S.M.
        • Ardo A.S.
        • Rifai K.T.
        In vitro evaluation of the “replica technique” in the measurement of the fit of procera crowns.
        J Contemp Dent Pract. 2008; 9: 25-32
        • Tian T.
        • Tsoi J.K.
        • Matinlinna J.P.
        • Burrow M.F.
        Aspects of bonding between resin luting cements and glass ceramic materials.
        Dent Mater. 2014; 30: e147-e162
        • Gresnigt M.M.
        • Ozcan M.
        • van den Houten M.L.
        • Schipper L.
        • Cune M.S.
        Fracture strength, failure type andweibull characteristics of lithium disilicate and multiphase resin composite endocrowns under axial and lateral forces.
        Dent Mater. 2016; 32: 607-614
        • Goujat A.
        • Abouelleil H.
        • Colon P.
        • Jeannin C.
        • Pradelle N.
        • Seux D.
        • et al.
        Mechanical properties and internal fit of 4 CAD-CAM block materials.
        J Prosthet Dent. 2018 Mar; 119: 384-389
        • BankogluGungor M.
        • Turhan Bal B.
        • Yilmaz H.
        • Aydin C.
        • KarakocaNemli S.
        Fracture strength of CAD/CAM fabricated lithium disilicate and resin nano ceramic restorations used for endodontically treated teeth.
        Dent Mater J. 2017; 36: 135-141
        • El-Damanhoury H.M.
        • Haj-Ali R.N.
        • Platt J.A.
        Fracture resistance and microleakage of endocrowns utilizing three CAD-CAM blocks.
        Oper Dent. 2015; 40: 201-210
        • Aktas G.
        • Yerlikaya H.
        • Akca K.
        Mechanical failure of endocrowns manufactured with different ceramic materials: An in vitro biomechanical study.
        J Prosthodont. 2018; 27: 340-346
        • Nejatidanesh F.
        • Shakibamehr A.H.
        • Savabi O.
        Comparison of marginal and internal adaptation of CAD/CAM and conventional cement retained implant-supported single crowns.
        Implant Dent. 2016; 25: 103-108
        • Rippe M.P.
        • Monaco C.
        • Volpe L.
        • Bottino M.A.
        • Scotti R.
        • Valandro L.F.
        Different methods for inlay production: Effect on internal and marginal adaptation, adjustment time, and contact point.
        Oper Dent. 2017; 42: 436-444
        • Nassar U.
        • Chow A.K.
        Surface detail reproduction and effect of disinfectant and long-term storage on the dimensional stability of a novel vinyl polyether silicone impression material.
        J Prosthodont. 2015; 24: 494-498
        • Schonberger J.
        • Erdelt K.J.
        • Baumer D.
        • Beuer F.
        Evaluation of two protocols to measure the accuracy of fixed dental prostheses: An in vitro study.
        J Prosthodont. 2019; 28: e599-e603