Advertisement
Journal of Prosthetic Dentistry

Immediate or delayed loading protocols for two-implant mandibular overdentures: A systematic review and meta-analysis of randomized controlled trials

      Abstract

      Statement of problem

      The immediate loading protocol for 2-implant mandibular overdentures has been widely reported. Nevertheless, the clinical effects reported in different articles are quite different.

      Purpose

      The purpose of this systematic review and meta-analysis of randomized controlled trials (RCTs) was to compare the clinical effects of immediate and delayed loading of 2-implant mandibular overdentures.

      Material and methods

      The review followed the guidelines of Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA). PubMed, Cochrane Library, Web of Science, Embase, Scopus, ScienceDirect, CBM, CNKI, and Wan Fang databases were searched electronically for RCTs published before March 25, 2020. Two authors independently conducted literature screening, quality assessment, and data extraction. The outcomes of interest were implant failure rate, marginal bone loss (MBL), implant stability quotient (ISQ), periotest value (PTV), and patient satisfaction.

      Results

      A total of 2498 unduplicated records were identified. After full-text analysis, 7 eligible RCTs were included. All studies were followed for at least 12 months, and the meta-analysis was based on this. The meta-analysis showed that the implant failure rate in the immediate group was higher than that in the delayed group, but there was no statistically significant difference (I2=0%; n=7; risk difference [RD]=0.03; 95% confidence interval [CI]=-0.01 to 0.08). The difference of MBL between immediate and delayed loading was not significant (I2=88%; n=6; mean difference [MD]=-0.04; 95% CI=-0.16 to 0.24). Because of the limited articles reporting on ISQ, PTV, and patient satisfaction, no quantitative analysis was conducted for these outcomes.

      Conclusions

      Although the implant failure rate was more likely to favor the delayed group, available evidence indicates no statistical difference in implant failure and marginal bone loss between immediate and delayed loading protocols.
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Journal of Prosthetic Dentistry
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Feine J.S.
        • Carlsson G.E.
        • Awad M.A.
        • Chehade A.
        • Duncan W.J.
        • Gizani S.
        • et al.
        The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients. Montreal, Quebec, May 24-25, 2002.
        Int J Oral Maxillofac Implants. 2002; 17: 601-602
        • Probst L.F.
        • Vanni T.
        • Cavalcante D.F.B.
        • Silva E.T.D.
        • Cavalcanti Y.W.
        • Passeri L.A.
        • et al.
        Cost-effectiveness of implant-supported dental prosthesis compared to conventional dental prosthesis.
        Rev Saude Publica. 2019; 53: 69
        • von der Gracht I.
        • Derks A.
        • Haselhuhn K.
        • Wolfart S.
        EMG correlations of edentulous patients with implant overdentures and fixed dental prostheses compared to conventional complete dentures and dentates: a systematic review and meta-analysis.
        Clin Oral Implants Res. 2017; 28: 765-773
        • Elsyad M.A.
        • Elgamal M.
        • Mohammed Askar O.
        • Youssef Al-Tonbary G.
        Patient satisfaction and oral health-related quality of life (OHRQoL) of conventional denture, fixed prosthesis and milled bar overdenture for All-on-4 implant rehabilitation. A crossover study.
        Clin Oral Implants Res. 2019; 30: 1107-1117
        • Feine J.
        • Abou-Ayash S.
        • Al Mardini M.
        • de Santana R.B.
        • Bjelke-Holtermann T.
        • Bornstein M.M.
        • et al.
        Group 3 ITI consensus report: patient-reported outcome measures associated with implant dentistry.
        Clin Oral Implants Res. 2018; 29 Suppl 16: 270-275
        • Brånemark P.I.
        • Hansson B.O.
        • Adell R.
        • Breine U.
        • Lindström J.
        • Hallén O.
        • et al.
        Osseointegrated implants in the treatment of the edentulous jaw. experience from a 10-year period.
        Scand J Plast Reconstr Surg Suppl. 1977; 16: 1-132
        • Omura Y.
        • Kanazawa M.
        • Sato D.
        • Kasugai S.
        • Minakuchi S.
        Comparison of patient-reported outcomes between immediately and conventionally loaded mandibular two-implant overdentures: a preliminary study.
        J Prosthodont Res. 2016; 60: 185-192
        • Morton D.
        • Gallucci G.
        • Lin W.S.
        • Pjetursson B.
        • Polido W.
        • Roehling S.
        • et al.
        Group 2 ITI consensus report: prosthodontics and implant dentistry.
        Clin Oral Implants Res. 2018; 29 Suppl 16: 215-223
        • Cheng Q.
        • Su Y.Y.
        • Wang X.
        • Chen S.
        Clinical outcomes following immediate loading of single-tooth implants in the esthetic zone: a systematic review and meta-analysis.
        Int J Oral Maxillofac Implants. 2020; 35: 167-177
        • Del Fabbro M.
        • Testori T.
        • Kekovic V.
        • Goker F.
        • Tumedei M.
        • Wang H.L.
        A systematic review of survival rates of osseointegrated implants in fully and partially edentulous patients following immediate loading.
        J Clin Med. 2019; 8: 2142
        • Cesaretti G.
        • Lang N.P.
        • Viganò P.
        • Bengazi F.
        • Apaza Alccayhuaman K.A.
        • Botticelli D.
        Immediate and delayed loading of fixed dental prostheses supported by single or two splinted implants: a histomorphometric study in dogs.
        J Oral Rehabil. 2018; 45: 308-316
        • Rea M.
        • Botticelli D.
        • Ricci S.
        • Soldini C.
        • González G.G.
        • Lang N.P.
        Influence of immediate loading on healing of implants installed with different insertion torques--an experimental study in dogs.
        Clin Oral Implants Res. 2015; 26: 90-95
        • Donati M.
        • Botticelli D.
        • La Scala V.
        • Tomasi C.
        • Berglundh T.
        Effect of immediate functional loading on osseointegration of implants used for single tooth replacement. A human histological study.
        Clin Oral Implants Res. 2013; 24: 738-745
        • Sommer M.
        • Zimmermann J.
        • Grize L.
        • Stübinger S.
        Marginal bone loss one year after implantation: a systematic review of different loading protocols.
        Int J Oral Maxillofac Surg. 2020; 49: 121-134
        • Alfadda S.A.
        • Chvartszaid D.
        • Tulbah H.I.
        • Finer Y.
        Immediate versus conventional loading of mandibular implant-supported fixed prostheses in edentulous patients: 10-year report of a randomised controlled trial.
        Int J Oral Implantol (Berl). 2019; 12: 431-446
        • Lefkove M.D.
        • Beals R.P.
        Immediate loading of cylinder implants with overdentures in the mandibular symphysis: the titanium plasma-sprayed screw technique.
        J Oral Implantol. 1990; 16: 265-271
        • Rosenlicht J.L.
        Advanced surgical techniques in implant dentistry: contemporary applications of early techniques.
        J Dent Symp. 1993; 1: 16-19
        • Chiapasco M.
        • Gatti C.
        • Rossi E.
        • Haefliger W.
        • Markwalder T.H.
        Implant-retained mandibular overdentures with immediate loading. A retrospective multicenter study on 226 consecutive cases.
        Clin Oral Implants Res. 1997; 8: 48-57
        • Gatti C.
        • Haefliger W.
        • Chiapasco M.
        Implant-retained mandibular overdentures with immediate loading: a prospective study of ITI implants.
        Int J Oral Maxillofac Implants. 2000; 15: 383-388
        • Sanda M.
        • Fueki K.
        • Bari P.R.
        • Baba K.
        Comparison of immediate and conventional loading protocols with respect to marginal bone loss around implants supporting mandibular overdentures: a systematic review and meta-analysis.
        Jpn Dent Sci Rev. 2019; 55: 20-25
        • Helmy M.H.E.D.
        • Alqutaibi A.Y.
        • El-Ella A.A.
        • Shawky A.F.
        Effect of implant loading protocols on failure and marginal bone loss with unsplinted two-implant-supported mandibular overdentures: systematic review and meta-analysis.
        Int J Oral Maxillofac Surg. 2018; 47: 642-650
        • Schimmel M.
        • Srinivasan M.
        • Herrmann F.R.
        • Müller F.
        Loading protocols for implant-supported overdentures in the edentulous jaw: a systematic review and meta-analysis.
        Int J Oral Maxillofac Implants. 2014; 29 Suppl: 271-286
        • Padmanabhan H.
        • Kumar S.M.
        • Kumar V.A.
        Single implant retained overdenture treatment protocol: a systematic review and meta-analysis.
        J Prosthodont. 2020; 29: 287-297
        • Alsabeeha N.
        • Atieh M.
        • Payne A.G.T.
        Loading protocols for mandibular implant overdentures: a systematic review with meta-analysis.
        Clin Implant Dent Relat Res. 2010; 12 Suppl 1: e28-e38
        • Kawai Y.
        • Taylor J.A.
        Effect of loading time on the success of complete mandibular titanium implant retained overdentures: a systematic review.
        Clin Oral Implants Res. 2007; 18: 399-408
        • Higgins J.
        • Altman D.
        • Gøtzsche P.
        • Jüni P.
        • Moher D.
        • Oxman A.
        • et al.
        The Cochrane Collaboration’s tool for assessing risk of bias in randomised trials.
        BMJ. 2011; 343: d5928
        • Hozo S.P.
        • Djulbegovic B.
        • Hozo I.
        Estimating the mean and variance from the median, range, and the size of a sample.
        BMC Med Res Methodol. 2005; 5: 13
        • Abou-Ayash S.
        • von Maltzahn N.
        • Passia N.
        • Freitag-Wolf S.
        • Reissmann D.R.
        • Luthardt R.G.
        • et al.
        Stabilizing mandibular complete dentures by a single midline implant-influence on quality of life: 2-year results from a randomized clinical trial comparing different loading protocols.
        Clin Oral Investig. 2020; 24: 927-935
        • Acham S.
        • Rugani P.
        • Truschnegg A.
        • Wildburger A.
        • Wegscheider W.A.
        • Jakse N.
        Immediate loading of four interforaminal implants supporting a locator-retained mandibular overdenture in the elderly. Results of a 3-year randomized, controlled, prospective clinical study.
        Clin Implant Dent Relat Res. 2017; 19: 895-900
        • Assad A.S.
        • Hassan S.A.
        • Shawky Y.M.
        • Badawy M.M.
        Clinical and radiographic evaluation of implant-retained mandibular overdentures with immediate loading.
        Implant Dent. 2007; 16: 212-223
        • Chiapasco M.
        • Abati S.
        • Romeo E.
        • Vogel G.
        Implant-retained mandibular overdentures with Brånemark system MKII implants: a prospective comparative study between delayed and immediate loading.
        Int J Oral Maxillofac Implants. 2001; 16: 537-546
        • Romeo E.
        • Chiapasco M.
        • Lazza A.
        • Casentini P.
        • Ghisolfi M.
        • Iorio M.
        • et al.
        Implant-retained mandibular overdentures with ITI implants: a comparison of 2-year results between delayed and immediate loading.
        Clin Oral Implants Res. 2002; 13: 495-501
        • Elsyad M.A.
        • Al-Mahdy Y.F.
        • Fouad M.M.
        Marginal bone loss adjacent to conventional and immediate loaded two implants supporting a ball-retained mandibular overdenture: a 3-year randomized clinical trial.
        Clin Oral Implants Res. 2012; 23: 496-503
        • Elsyad M.A.
        • Elsaih E.A.
        • Khairallah A.S.
        Marginal bone resorption around immediate and delayed loaded implants supporting a locator-retained mandibular overdenture. A 1-year randomised controlled trial.
        J Oral Rehabil. 2014; 41: 608-618
        • Komagamine Y.
        • Kanazawa M.
        • Sato D.
        • Minakuchi S.
        A preliminary comparison of masticatory performances between immediately loaded and conventionally loaded mandibular two-implant overdentures with magnetic attachments.
        Clin Implant Dent Relat Res. 2019; 21: 130-137
        • Kutkut A.
        • Rezk M.
        • Zephyr D.
        • Dawson D.
        • Frazer R.
        • Al-Sabbagh M.
        Immediate loading of unsplinted implant retained mandibular overdenture: a randomized controlled clinical study.
        J Oral Implantol. 2019; 45: 378-389
        • Lahori M.
        • Kaul A.S.
        • Chandra S.
        • Nagrath R.
        • Gupta H.
        Comparative evaluation of bone in mandibular implant retained overdentures using delayed and immediate loading protocol: an in-vivo study.
        J Indian Prosthodont Soc. 2013; 13: 113-121
        • Salman A.
        • Thacker S.
        • Rubin S.
        • Dhingra A.
        • Ioannidou E.
        • Schincaglia G.P.
        Immediate versus delayed loading of mandibular implant-retained overdentures: a 60-month follow-up of a randomized clinical trial.
        J Clin Periodontol. 2019; 46: 863-871
        • Tözüm T.F.
        • Turkyilmaz I.
        • Yamalik N.
        • Karabulut E.
        • Türkyilmaz A.S.
        • Eratalay K.
        Analysis of the possibility of the relationship between various implant-related measures: an 18-month follow-up study.
        J Oral Rehabil. 2008; 35: 95-104
        • Alfadda S.A.
        • Chvartszaid D.
        • AlFarraj Aldosari A.
        Clinical outcomes of immediately loaded implant-supported overdentures: a long-term prospective clinical trial.
        J Prosthet Dent. 2019; 121: 911-915
        • Rignon-Bret C.
        • Wulfman C.
        • Hadida A.
        • Renouard F.
        • Gourraud P.A.
        • Naveau A.
        Immediate loading of two unsplinted implants in edentulous patients with mandibular overdentures: a 10-year retrospective review of patients from a previously conducted 1-year cohort study.
        Int J Oral Maxillofac Implants. 2019; 34: 169-178
        • Tettamanti L.
        • Andrisani C.
        • Bassi M.A.
        • Vinci R.
        • Silvestre-Rangil J.
        • Tagliabue A.
        Immediate loading implants: review of the critical aspects.
        Oral Implantol (Rome). 2017; 10: 129-139
        • Greenstein G.
        • Cavallaro J.
        Implant insertion torque: its role in achieving primary stability of restorable dental implants.
        Compend Contin Educ Dent. 2017; 38: 88-96
        • Ko Y.C.
        • Huang H.L.
        • Shen Y.W.
        • Cai J.Y.
        • Fuh L.J.
        • Hsu J.T.
        Variations in crestal cortical bone thickness at dental implant sites in different regions of the jawbone.
        Clin Implant Dent Relat Res. 2017; 19: 440-446
        • Makowiecki A.
        • Hadzik J.
        • Błaszczyszyn A.
        • Gedrange T.
        • Dominiak M.
        An evaluation of superhydrophilic surfaces of dental implants - a systematic review and meta-analysis.
        BMC Oral Health. 2019; 19: 79