Advertisement
Journal of Prosthetic Dentistry

Clinical performance of posterior monolithic zirconia implant-supported fixed dental prostheses with angulated screw channels: A 3-year prospective cohort study

  • Adolfo Di Fiore
    Correspondence
    Corresponding author: Dr Adolfo Di Fiore, Department of Neurosciences, Dental School, Section of Prosthodontics and Digital Dentistry, University of Padova, via Giustiniani 2, 35100, Padova, ITALY
    Affiliations
    Adjunct Professor, Department of Neurosciences, School of Dentistry, Section of Prosthodontics and Digital Dentistry, University of Padova, Padova, Italy
    Search for articles by this author
  • Stefano Granata
    Affiliations
    Adjunct Professor, Department of Neurosciences, School of Dentistry, Section of Prosthodontics and Digital Dentistry, University of Padova, Padova, Italy
    Search for articles by this author
  • Carlo Monaco
    Affiliations
    Researcher, Assistant Professor, Division of Prosthodontics and Maxillofacial Rehabilitation, Department of Biomedical and Neuromotor Sciences (DIBINEM), Alma Mater Studiorum— University of Bologna, Bologna, Italy
    Search for articles by this author
  • Edoardo Stellini
    Affiliations
    Full Professor and Head of Dental Clinic and School of Dentistry, Department of Neurosciences, University of Padova, Padova, Italy
    Search for articles by this author
  • Burak Yilmaz
    Affiliations
    Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland

    Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland

    Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, Ohio
    Search for articles by this author

      Abstract

      Statement of problem

      The choice of retention type of an implant-supported fixed dental prosthesis (FDP) becomes critical when the dental implant is not placed in a prosthetically ideal location. In recent years, computer-aided design and computer-aided manufacturing (CAD-CAM) technology has enabled the correction of the location of screw access hole depending on the clinical needs of the patient. However, how FPDs with angulated screw channels (ASCs) perform clinically is unclear.

      Purpose

      The purpose of this prospective clinical study was to evaluate the mechanical complications and crestal bone loss (CBL) when posterior monolithic zirconia implant-supported FDPs with an ASC are used.

      Material and methods

      Participants (N=37) with a missing single posterior tooth or multiple teeth, sufficient bone height, and an implant site without infection were included. Each participant received parallel-walled implants (Nobel Parallel CC) of 7-, 8.5-, or 10-mm length by using a 1-stage approach. After 4 months of healing, a conventional impression was made, and a digital workflow was followed. Monolithic zirconia restorations (Katana ML) were milled, stained, and mechanically attached to a titanium base (NobelProcera ASC abutment). CBL was measured from radiographs at 6, 12, 24, and 36 months after the placement of the prosthesis. Implant and prosthetic characteristics including implant diameter, implant length, screw channel angle (angle≤15 degrees versus angle>16 degrees), prosthetic type (single crown versus multiple-unit FDP), and antagonist dentition (natural versus prosthesis) were also recorded. A generalized linear mixed model with a log link was estimated to assess the independent predictors of CBL among the angles of ASC-retained definitive restorations and the clinically relevant variables (α=.05).

      Results

      Thirty-seven participants received 51 implants, and the median follow-up period was 30 months (interquartile range: 22-36). Two single-crown implants failed within the first 12 months of delivery. The implant and restoration survival rate was 96% at 36 months. Screw loosening was recorded in 2 study participants. After a follow-up of 36 months, the mean ±standard deviation CBL value was 0.15 ±0.14 mm with an increase over time (P<.001). The effect of the angle of ASC, implant diameter, implant length, prosthetic type, and antagonist on the CBL was not statistically significant (P>.05).

      Conclusions

      CBL was not associated with the angle of ASC, implant diameter, implant length, prosthetic type, or antagonist when posterior monolithic zirconia implant-supported FDPs with ASCs were used. Screw loosening in 2 situations was the only mechanical complication during the first 3 years of service.
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Journal of Prosthetic Dentistry
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Wittneben J.G.
        • Millen C.
        • Brägger U.
        Clinical performance of screw- versus cement-retained fixed implant-supported reconstructions - A systematic review.
        Int J Oral Maxillofac Implants. 2014; 29: 84-98
        • Hebel K.S.
        • Gajjar R.C.
        Cement-retained versus screw-retained implant restorations: achieving optimal occlusion and aesthetics in implant dentistry.
        J Prosthet Dent. 1997; 77: 28-35
        • Wilson T.J.
        The positive relationship between excess cement and peri-implant disease: a prospective clinical endoscopic study.
        J Periodontol. 2009; 80: 1388-1392
        • Wadhwani C.
        • Rapoport D.
        • La Rosa S.
        • Hess T.
        • Kretschmar S.
        Radiographic detection and characteristic patterns of residual excess cement associated with cement-retained implant restorations: a clinical report.
        J Prosthet Dent. 2012; 107: 151-157
        • Korsch M.
        • Robra B.P.
        • Walther W.
        Cement-associated signs of inflammation: retrospective analysis of the effect of excess cement on peri-implant tissue.
        Int J Prosthodont. 2015; 28: 11-18
        • Shadid R.
        • Sadaqa N.
        A comparison between screw- and cement- retained implant prostheses. A literature review.
        J Oral Implantol. 2012; 38: 298-307
        • Sakamoto S.
        • Ro M.
        • Al-Ardah A.
        • Goodacre C.
        Esthetic abutment design for angulated screw channels: a technical report.
        J Prosthet Dent. 2018; 119: 912-915
        • Garcia-Gazaui S.
        • Razzoog M.
        • Sierraalta M.
        • Saglik B.
        Fabrication of a screw-retained restoration avoiding the facial access hole: a clinical report.
        J Prosthet Dent. 2015; 114: 621-624
        • Gjelvold B.
        • Sohrabi M.M.
        • Chrcanovic B.R.
        Angled screw channel: an alternative to cemented single-implant restorations--three clinical examples.
        Int J Prosthodont. 2016; 29: 74-76
        • Cavallaro Jr., J.
        • Greenstein G.
        Angled implant abutments: a practical application of 20 available knowledge.
        J Am Dent Assoc. 2011; 142: 150-158
        • Lin C.L.
        • Wang J.C.
        • Ramp L.C.
        • Liu P.R.
        Biomechanical response of implant systems placed in the maxillary posterior region under various conditions of angulation, bone density, and loading.
        Int J Oral Maxillofac Implants. 2008; 23: 57-64
        • Isidor F.
        Influence of forces on peri-implant bone.
        Clin Oral Implants Res. 2006; 17: 8-18
        • Greer A.C.
        • Hoyle P.J.
        • Vere J.W.
        • Wragg P.F.
        Mechanical complications associated with angled screw channel restorations.
        Int J Prosthodont. 2017; 30: 258-259
        • Anitua E.
        • Flores C.
        • Piñas L.
        • Alkhraisat M.H.
        Frequency of technical complications in fixed implant prosthesis: the effect of prosthesis screw emergence correction by computer-aided design/computer-aided manufacturing.
        J Oral Implantol. 2018; 44: 427-431
        • Friberg B.
        • Ahmadzai M.
        A prospective study on single tooth reconstructions using parallel walled implants with internal connection (NobelParallel CC) and abutments with angulated screw channels (ASC).
        Clin Implant Dent Relat Res. 2019; 21: 226-231
        • Anitua E.
        • Fernández-de-Retana S.
        • Alkhraisat M.H.
        Survival and marginal bone loss of dental implants supporting CAD-CAM angled channel restorations: a split-mouth retrospective study.
        Eur J Dent. 2020; 14: 194-199
        • Pol C.W.P.
        • Raghoebar G.M.
        • Maragkou Z.
        • Cune M.S.
        • Meijer H.J.A.
        Full-zirconia single-tooth molar implant-supported restorations with angulated screw channel abutments: a 1-year prospective case series study.
        Clin Implant Dent Relat Res. 2020; 22: 138-144
        • Arena A.
        • Prete F.
        • Rambaldi E.
        • Bignozzi M.C.
        • Monaco C.
        • Di Fiore A.
        • et al.
        Nanostructured zirconia-based ceramics and composites in dentistry: a state-of-the-art review.
        Nanomaterials (Basel). 2019; 9: 1393
        • Worni A.
        • Kolgeci L.
        • Rentsch-Kollar A.
        • Katsoulis J.
        • Mericske-Stern R.
        Zirconia-based screw-retained prostheses supported by implants: a retrospective study on technical complications and failures.
        Clin Implant Dent Relat Res. 2015; 17: 1073-1081
        • Pjetursson B.E.
        • Valente N.A.
        • Strasding M.
        • Zwahlen M.
        • Liu S.
        • Sailer I.
        A systematic review of the survival and complication rates of zirconiaceramic and metal-ceramic single crowns.
        Clin Oral Implants Res. 2018; 29: 199-214
        • Spitznagel F.A.
        • Horvath S.D.
        • Gierthmuehlen P.C.
        Prosthetic protocols in implant-based oral rehabilitations: a systematic review on the clinical outcome of monolithic all-ceramic single- and multi-unit prostheses.
        Eur J Oral Implantol. 2017; 10: 89-99
        • Jung R.E.
        • Zembic A.
        • Pjetursson B.E.
        • Zwahlen M.
        • Thoma D.S.
        Systematic review of the survival rate the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow up of 5 years.
        Clin Oral Implants Res. 2012; 23: 2-21
        • Pjetursson B.E.
        • Thoma D.
        • Jung R.
        • Zwahlen M.
        • Zembic A.
        A systematic review of the survival and complication rates of implant-supported fixed dental prostheses (FDPs) after a mean observation period of at least 5 years.
        Clin Oral Implants Res. 2012; 23: 22-38
        • Di Fiore A.
        • Vigolo P.
        • Sivolella S.
        • Cavallin F.
        • Katsoulis J.
        • Monaco C.
        • et al.
        Influence of Crown-to-Implant Ratio on Long-Term Marginal Bone Loss Around Short Implants.
        Int J Oral Maxillofac Implants. 2019; 34: 992-998
        • Sivolella S.
        • Stellini E.
        • Testori T.
        • Di Fiore A.
        • Berengo M.
        • Lops D.
        Splinted and unsplinted short implants in mandibles: a retrospective evaluation with 5 to 16 years of follow-up.
        J Periodontol. 2013; 84: 502-512
        • Swamidass R.S.
        • Kan J.Y.K.
        • Kattadiyil M.T.
        • Goodacre C.J.
        • Lozada J.
        Abutment screw torque changes with straight and angled screw-access channels.
        J Prosthet Dent. 2021; 125: 675-681
        • Hu E.
        • Petrich A.
        • Imamura G.
        • Hamlin C.
        Effect of screw channel angulation on reverse torque values of dental implant abutment screws.
        J Prosthodont. 2019; 28: 969-972
        • Ceruso F.M.
        • Barnaba P.
        • Mazzoleni S.
        • Ottria L.
        • Gargari M.
        • Zuccon A.
        • et al.
        Implant-abutment connections on single crowns: a systematic review.
        Oral Implantol (Rome). 2017; 10: 349-353
        • Telleman G.
        • Raghoebar G.M.
        • Vissink A.
        • den Hartog L.
        • Huddleston Slater J.J.
        • Meijer H.J.
        A systematic review of the prognosis of short (<10 mm) dental implants placed in the partially edentulous patient.
        J Clin Periodontol. 2011; 38: 667-676
        • Walton T.R.
        • Layton D.M.
        Intra- and inter-examiner agreement when assessing radiographic implant bone levels: differences related to brightness, accuracy, participant demographics and implant characteristics.
        Clin Oral Implants Res. 2018; 29: 756-771