Advertisement
Journal of Prosthetic Dentistry
Tips from Our Readers| Volume 129, ISSUE 3, P520-522, March 2023

Download started.

Ok

Radiographic template used to facilitate the alignment of digital scans to computed tomography scans with extensive beam hardening artifacts

  • Christian A. Loo
    Correspondence
    Corresponding author: Dr Christian A. Loo, Division of Restorative and Prosthetic Dentistry, The Ohio State University, Postle Hall 305 W. 12th Avenue, Columbus, OH 43210
    Affiliations
    Graduate student, Advanced Prosthodontics Program, Division of Restorative and Prosthetic Dentistry, College of Dentistry, The Ohio State University, Columbus, Ohio
    Search for articles by this author
  • Francisco X. Azpiazu-Flores
    Affiliations
    Graduate student, Advanced Prosthodontics Program, Division of Restorative and Prosthetic Dentistry, College of Dentistry, The Ohio State University, Columbus, Ohio
    Search for articles by this author
Published:September 04, 2021DOI:https://doi.org/10.1016/j.prosdent.2021.07.018
      Endosteal dental implants have shown to be an excellent long-term resource for the treatment of edentulism.
      • Malo P.
      • de Araujo Nobre M.
      • Lopes A.
      The use of computer-guided flapless implant surgery and four implants placed in immediate function to support a fixed denture: preliminary results after a mean follow-up period of thirteen months.
      For decades, restorative-driven implant placement has been considered the norm for patient care,
      • Van Assche N.
      • Vercruyssen M.
      • Coucke W.
      • Teughels W.
      • Jacobs R.
      • Quirynen M.
      Accuracy of computer-aided implant placement.
      ,
      • Garber D.A.
      The esthetic dental implant: letting restoration be the guide.
      and careful presurgical planning by using accurate diagnostic elements is widely recognized as a requirement for predictable, esthetic, and functional implant placement.
      • Garber D.A.
      The esthetic dental implant: letting restoration be the guide.
      Computer-generated surgical guides generated from computed tomography (CT) scans are widely used and have been shown to be a resource that improves the outcomes of implant surgery.
      • Ozan O.
      • Turkyilmaz I.
      • Ersoy A.E.
      • McGlumphy E.A.
      • Rosenstiel S.F.
      Clinical accuracy of 3 different types of computed tomography-derived stereolithographic surgical guides in implant placement.
      ,
      • Ersoy A.E.
      • Turkyilmaz I.
      • Ozan O.
      • McGlumphy E.A.
      Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: clinical data from 94 implants.
      The accurate reproduction and stability of the tissues that will support the guide is essential, and rigid references such as teeth or dental implants have been used successfully to support surgical guides.
      • Ozan O.
      • Turkyilmaz I.
      • Ersoy A.E.
      • McGlumphy E.A.
      • Rosenstiel S.F.
      Clinical accuracy of 3 different types of computed tomography-derived stereolithographic surgical guides in implant placement.
      ,
      • Simon H.
      Use of transitional implants to support a surgical guide: enhancing the accuracy of implant placement.
      However, in patients with multiple metal restorations, radiographic artifacts such as beam hardening or scatter can obscure the areas of interest,
      • Monsour P.A.
      • Dudhia R.
      Implant radiography and radiology.
      thus complicating the accurate 3-dimensional recreation of the intraoral tissues in the planning software program.
      • Borisov R.
      Use of plastic material and triple scan in the preparation of surgical guides for the dental implant treatment-case report.
      An approach used to overcome this problem is the triple-scan technique.
      • Borisov R.
      Use of plastic material and triple scan in the preparation of surgical guides for the dental implant treatment-case report.
      In this technique, 3 independent scans are aligned in an implant planning software program to allow the accurate reproduction and visualization of the intraoral tissues. Usually, the 3 scans consist of a high-resolution intraoral scan, a CT scan made with an impression tray loaded with elastomeric impression material, and a CT scan of the same impression tray out of the mouth.
      • Borisov R.
      Use of plastic material and triple scan in the preparation of surgical guides for the dental implant treatment-case report.
      Although this technique is effective, the patient may find it unpleasant because of the bulk of the impression material and the difficult removal when undercuts are present. In addition, this approach can result in inaccuracies because of difficulty in visualizing the separation of the tray from the intraoral tissues.
      The purpose of this article was to introduce a straightforward but effective alternative to the triple-scan technique. In this approach, an acrylic resin radiographic stent with fiducial markers was used to relate high-resolution digital scans to the CT scan of a patient with multiple implant-supported restorations and abundant radiographic beam hardening artifacts. This approach allowed the accurate reproduction of the surface of the existing prostheses, thus allowing its use as the foundation for the computer-generated surgical template. An additional advantage of the described technique is that the guide is made from a clear material to allow the visual inspection of complete seating. For this reason, it is placed more easily and reliably than a tray filled with elastomeric impression material. Unlike techniques where fiducial markers are placed directly on the prostheses, this technique does not require the use of an intraoral scanner. The added distance between the fiducial markers and the restorations with this technique also reduces the possibility of interfering artifacts.

      Technique

      • 1.
        Make an impression (Silginat; Kettenbach USA) that reproduces the anticipated areas that will support the surgical template. Pour the preliminary impressions conventionally with dental stone (Buff Stone; Whip Mix Corp) and fabricate a diagnostic cast and a definitive cast. With a tungsten carbide laboratory cutter (H251SA.11.060 HP SGE-Cutter Carbide; Brasseler USA), create multiple notches in the edges of the land area of the diagnostic cast. Subsequently, scan the diagnostic cast with a benchtop laboratory scanner (E3; 3Shape A/S). Make sure the areas that will support the future surgical template are well defined in the scan.
      • 2.
        By using the definitive cast, fabricate a 3-mm device with a thermoplastic polymer (Clear Splint Biocryl 3mm/125mm; Great Lakes Dental Technologies) via pressure molding (Biostar Scan with LCD Display; Great Lakes Dental Technologies).
      • 3.
        Prepare the surface of the device by applying acrylic monomer (Ortho-Jet Liquid; Lang Dental Manufacturing, Co) and add polymethyl methacrylate resin (Ortho-Jet Powder; Lang Dental Manufacturing, Co) to the occlusal surface of the clear device. Carefully trim the added resin to an approximate height of 10 mm above the occlusal plane. Remove the device from the definitive cast and verify that it fits accurately on the diagnostic cast.
      • 4.
        Evaluate the device intraorally and verify its stability. Subsequently, adjust the height of the device while maintaining parallelism to the occlusal plane as much as possible. Apply fiducial markers (V-20; The SureMark Co) to the device, with maximum spread across the dental arch (Fig. 1). Make a CT scan with the device in position.
        Figure thumbnail gr1
        Figure 1A, Intraoral image of mandibular arch restored with metal-ceramic restorations which caused extensive beam hardening artifacts. B, Device in place. Note adequate adaptation and widely spread fiducial markers on occlusal surface of device.
      • 5.
        Scan the diagnostic cast with the device in place (Fig. 2). Align the CT scan and digital cast with the device by using corresponding fiducial marker points (Fig. 3A). Align the digital cast with the device and digital cast without the device by using the corresponding notches made in the land area (Fig. 3B, 3C).
        Figure thumbnail gr2
        Figure 2Diagnostic cast with device used to create scan to align with scan of diagnostic cast alone to computed tomography scan.
        Figure thumbnail gr3
        Figure 3A, Volumetric cast generated from computed tomography scan. Note radiopaque fiducial markers above beam hardening artifacts. B, Digital scans of diagnostic cast with radiographic stent and diagnostic cast alone aligned to volumetric model. C, Alignment.

      References

        • Malo P.
        • de Araujo Nobre M.
        • Lopes A.
        The use of computer-guided flapless implant surgery and four implants placed in immediate function to support a fixed denture: preliminary results after a mean follow-up period of thirteen months.
        J Prosthet Dent. 2007; 97: S26-S34
        • Van Assche N.
        • Vercruyssen M.
        • Coucke W.
        • Teughels W.
        • Jacobs R.
        • Quirynen M.
        Accuracy of computer-aided implant placement.
        Clin Oral Implants Res. 2012; 23 Suppl 6: 112-123
        • Garber D.A.
        The esthetic dental implant: letting restoration be the guide.
        J Am Dent Assoc. 1995; 126: 319-325
        • Ozan O.
        • Turkyilmaz I.
        • Ersoy A.E.
        • McGlumphy E.A.
        • Rosenstiel S.F.
        Clinical accuracy of 3 different types of computed tomography-derived stereolithographic surgical guides in implant placement.
        J Oral Maxillofac Surg. 2009; 67: 394-401
        • Ersoy A.E.
        • Turkyilmaz I.
        • Ozan O.
        • McGlumphy E.A.
        Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: clinical data from 94 implants.
        J Periodontol. 2008; 79: 1339-1345
        • Simon H.
        Use of transitional implants to support a surgical guide: enhancing the accuracy of implant placement.
        J Prosthet Dent. 2002; 87: 229-232
        • Monsour P.A.
        • Dudhia R.
        Implant radiography and radiology.
        Aust Dent J. 2008; 53 Suppl 1: S11-S25
        • Borisov R.
        Use of plastic material and triple scan in the preparation of surgical guides for the dental implant treatment-case report.
        J IMAB. 2016; 22: 1279-1284