Advertisement
Research and Education|Articles in Press

Effect of printing layer thickness on the trueness of 3-unit interim fixed partial dentures

  • Gülce Çakmak
    Correspondence
    Corresponding author: Dr Gülce Çakmak, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Freiburgstrasse 7, Bern 3010, SWITZERLAND
    Affiliations
    Buser Foundation Scholar for Implant Dentistry, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
    Search for articles by this author
  • Alfonso Rodriguez Cuellar
    Affiliations
    Professor, Department of Periodontology, Clinica Dental Rodriguez Dental Clinic, Mexico City, Mexico
    Search for articles by this author
  • Mustafa Borga Donmez
    Affiliations
    Assistant Professor, Department of Prosthodontics, Istinye University Faculty of Dentistry, Istanbul, Turkey

    Visiting Researcher, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
    Search for articles by this author
  • Samir Abou-Ayash
    Affiliations
    Senior Lecturer and Head of the Section of Digital Implant and Reconstructive Dentistry, Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland
    Search for articles by this author
  • Wei-En Lu
    Affiliations
    PhD student, Division of Biostatistics, The Ohio State University College of Public Health, Columbus, Ohio
    Search for articles by this author
  • Martin Schimmel
    Affiliations
    Chairman, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland

    External Researcher, Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
    Search for articles by this author
  • Burak Yilmaz
    Affiliations
    Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland

    Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland

    Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio
    Search for articles by this author
Open AccessPublished:May 27, 2022DOI:https://doi.org/10.1016/j.prosdent.2022.04.015

      Abstract

      Statement of problem

      Three-dimensional printing has facilitated the fabrication processes in dentistry. However, knowledge on the effect of layer thickness on the trueness of 3D-printed fixed partial dentures (FPDs) is lacking.

      Purpose

      The purpose of this in vitro study was to compare the effect of printing layer thickness on the trueness of 3-unit interim FPDs fabricated by using additive manufacturing with that of those fabricated by subtractive manufacturing.

      Material and methods

      The right first premolar and first molar teeth of a dentate mandibular model were prepared for a 3-unit restoration and then digitized by using an intraoral scanner. A 3-unit interim FPD was designed to fabricate 40 restorations by using either the additive (NextDent C&B MFH) with layer thicknesses of 20 μm (n=10), 50 μm (n=10), and 100 μm (n=10) or subtractive manufacturing technique (Upcera) (milled, n=10). After fabrication, the interim FPDs were digitized by using the same intraoral scanner and were superimposed over the design data by using a 3D analysis software program. Root mean square (RMS) was used to analyze the trueness of the restorations at 4 different surfaces (external, intaglio, marginal area, and intaglio occlusal) and as a complete unit (overall). Data were analyzed with the Kruskal-Wallis and Wilcoxon tests with Bonferroni correction (α=.05).

      Results

      The 100-μm-layer thickness interim FPDs showed the greatest overall (P≤.015), external (P≤.021), and intaglio occlusal (P≤.021) deviations, whereas the milled interim FPDs showed the lowest (P=.001). No significant differences were found among the test groups for marginal RMS (P≥.108). The differences between the 50-μm-layer thickness and 100-μm-layer thickness interim FPDs for the intaglio surface deviations (P=.064) and between the 20-μm-layer thickness and 50-μm-layer thickness interim FPDs for each surface tested were not statistically significant (P≥.108).

      Conclusions

      The printing layer thickness had a significant effect on the trueness of the additively manufactured interim FPDs. However, subtractively manufactured interim FPDs presented higher trueness than those additively manufactured, regardless of the printing layer thickness.
      Clinical Implications
      For the tested 3D-printed resin, 20- and 50-μm-layer thickness interim fixed partial dentures presented lower deviations. Therefore, these FPDs may require less chairside adjustment and have better marginal adaptation than when a 100-μm-layer thickness is used.
      Computer-aided design and computer-aided manufacturing (CAD-CAM) systems operate in 3 stages: data acquisition by using a scanner, processing the acquired data to form a standard tessellation language (STL) file, and manufacturing either via subtractive or additive method.
      • van Noort R.
      The future of dental devices is digital.
      • Dawood A.
      • Marti Marti B.
      • Sauret-Jackson V.
      • Darwood A.
      3D printing in dentistry.
      • Beuer F.
      • Schweiger J.
      • Edelhoff D.
      Digital dentistry: an overview of recent developments for CAD/CAM generated restorations.
      • Methani M.M.
      • Revilla-León M.
      • Zandinejad A.
      The potential of additive manufacturing technologies and their processing parameters for the fabrication of all-ceramic crowns: a review.
      Subtractive manufacturing (SM) is the fabrication of an object from a block or disk with various processes such as milling, grinding, drilling, turning, and polishing.
      • Kessler A.
      • Hickel R.
      • Reymus M.
      3D printing in dentistry-state of the art.
      • Lee W.S.
      • Lee D.H.
      • Lee K.B.
      Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system.
      • Alharbi N.
      • Osman R.
      • Wismeijer D.
      Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations.
      Even though SM has been synonymous with CAM,
      • Kessler A.
      • Hickel R.
      • Reymus M.
      3D printing in dentistry-state of the art.
      additive manufacturing (AM) or 3-dimensional (3D) printing has become increasingly popular in dentistry, with a number of applications for fabricating casts, surgical guides, crown or partial denture frameworks, implant-supported prostheses, and orthodontic appliances.
      • Dawood A.
      • Marti Marti B.
      • Sauret-Jackson V.
      • Darwood A.
      3D printing in dentistry.
      ,
      • Dikova T.
      • Dzhendov D.
      • Ivanov D.
      • Bliznakova K.
      Dimensional accuracy and surface roughness of polymeric dental bridges produced by different 3D printing processes.
      AM is the process of combining 3D data in consecutive layers
      • Dikova T.
      • Dzhendov D.
      • Katreva I.
      • Pavlova D.
      Accuracy of polymeric dental bridges manufactured by stereolithography.
      and has advantages over SM in terms of passive and vertical manufacturing, recycling of the unused material, and the possibility of producing larger and more complex objects and of increasing the number of products to be manufactured at a time.
      • Jockusch J.
      • Özcan M.
      Additive manufacturing of dental polymers: an overview on processes, materials and applications.
      ,
      • Shim J.S.
      • Kim J.E.
      • Jeong S.H.
      • Choi Y.J.
      • Ryu J.J.
      Printing accuracy, mechanical properties, surface characteristics, and microbial adhesion of 3D-printed resins with various printing orientations.
      The American Section of the International Association for Testing Materials (ASTM) International Standard Organization has categorized AM into 7 methods
      with stereolithography (SLA), in which a liquid resin is polymerized by an ultraviolet laser, being the most commonly used method for dentistry.
      • Kessler A.
      • Hickel R.
      • Reymus M.
      3D printing in dentistry-state of the art.
      An alternative to SLA is digital light processing (DLP), a method based on the activation of light-sensitive monomers by the projection of a laser. The laser beam is directed by a digital micromirror device (DMD), which consists of a vast number of micromirrors that control the reflection path of the light.
      • Osman R.B.
      • Alharbi N.
      • Wismeijer D.
      Build angle: does it influence the accuracy of 3D-printed dental restorations using digital light-processing technology?.
      ,
      • Park G.S.
      • Kim S.K.
      • Heo S.J.
      • Koak J.Y.
      • Seo D.G.
      Effects of printing parameters on the fit of implant-supported 3d printing resin prosthetics.
      Interim restorations are pivotal for the success of a prosthetic rehabilitation as they replace the missing tooth structure and thereby provide biological and mechanical protection as well as positional stability.
      • Peng C.C.
      • Chung K.H.
      • Yau H.T.
      • Ramos Jr., V.
      Assessment of the internal fit and marginal integrity of interim crowns made by different manufacturing methods.
      ,
      • Peng C.C.
      • Chung K.H.
      • Ramos Jr., V.
      Assessment of the adaptation of interim crowns using different measurement techniques.
      Currently methacrylate polymers and composite resins are typically used for interim restorations.
      • Dikova T.
      Production of high-quality temporary crowns and bridges by stereolithography.
      Polymethyl methacrylate (PMMA) is the leading alternative among these materials because of its low cost, ease of fabrication, and reliability.
      • Peng C.C.
      • Chung K.H.
      • Yau H.T.
      • Ramos Jr., V.
      Assessment of the internal fit and marginal integrity of interim crowns made by different manufacturing methods.
      However, polymerization shrinkage, marginal discrepancies, and that the polymerization reaction of this material is exothermic are problems associated with the direct use of PMMA.
      • Peng C.C.
      • Chung K.H.
      • Yau H.T.
      • Ramos Jr., V.
      Assessment of the internal fit and marginal integrity of interim crowns made by different manufacturing methods.
      It is also possible to manufacture these restorations by using either SM or AM,
      • Lee W.S.
      • Lee D.H.
      • Lee K.B.
      Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system.
      ,
      • Peng C.C.
      • Chung K.H.
      • Ramos Jr., V.
      Assessment of the adaptation of interim crowns using different measurement techniques.
      ,
      • Alharbi N.
      • Osman R.B.
      • Wismeijer D.
      Factors influencing the dimensional accuracy of 3D-printed full-coverage dental restorations using stereolithography technology.
      ,
      • Mai H.N.
      • Lee K.B.
      • Lee D.H.
      Fit of interim crowns fabricated using photopolymer-jetting 3D printing.
      and compared with the conventional method, these CAD-CAM technologies lead to more rapid production with a final product that has higher precision and adaptation.
      • Dikova T.
      Production of high-quality temporary crowns and bridges by stereolithography.
      The accuracy of a printed object can be affected by the technology and software program used, laser speed, laser intensity, printing orientation, number of layers, printing angle, layer thickness, and postprocessing methods.
      • Alharbi N.
      • Osman R.
      • Wismeijer D.
      Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations.
      ,
      • Jockusch J.
      • Özcan M.
      Additive manufacturing of dental polymers: an overview on processes, materials and applications.
      ,
      • Shim J.S.
      • Kim J.E.
      • Jeong S.H.
      • Choi Y.J.
      • Ryu J.J.
      Printing accuracy, mechanical properties, surface characteristics, and microbial adhesion of 3D-printed resins with various printing orientations.
      ,
      • Alharbi N.
      • Osman R.B.
      • Wismeijer D.
      Factors influencing the dimensional accuracy of 3D-printed full-coverage dental restorations using stereolithography technology.
      ,
      • Simoneti D.M.
      • Pereira-Cenci T.
      • Dos Santos M.B.F.
      Comparison of material properties and biofilm formation in interim single crowns obtained by 3D printing and conventional methods.
      Printing orientation has been the main subject of interest of previous studies on 3D-printed interim materials.
      • Alharbi N.
      • Osman R.
      • Wismeijer D.
      Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations.
      ,
      • Shim J.S.
      • Kim J.E.
      • Jeong S.H.
      • Choi Y.J.
      • Ryu J.J.
      Printing accuracy, mechanical properties, surface characteristics, and microbial adhesion of 3D-printed resins with various printing orientations.
      ,
      • Osman R.B.
      • Alharbi N.
      • Wismeijer D.
      Build angle: does it influence the accuracy of 3D-printed dental restorations using digital light-processing technology?.
      ,
      • Alharbi N.
      • Osman R.B.
      • Wismeijer D.
      Factors influencing the dimensional accuracy of 3D-printed full-coverage dental restorations using stereolithography technology.
      ,
      • Yu B.Y.
      • Son K.
      • Lee K.B.
      Evaluation of intaglio surface trueness and margin quality of interim crowns in accordance with the build angle of stereolithography apparatus 3-dimensional printing.
      However, setting the ideal thickness, which is a controllable parameter,
      • Revilla-León M.
      • Özcan M.
      Additive manufacturing technologies used for processing polymers: current status and potential application in prosthetic dentistry.
      is also essential for optimal restoration properties.
      • Zhang Z.C.
      • Li P.L.
      • Chu F.T.
      • Shen G.
      Influence of the three-dimensional printing technique and printing layer thickness on model accuracy.
      Studies on the effects of layer thickness on the accuracy of 3D-printed interim restorations are sparse.
      • Park G.S.
      • Kim S.K.
      • Heo S.J.
      • Koak J.Y.
      • Seo D.G.
      Effects of printing parameters on the fit of implant-supported 3d printing resin prosthetics.
      ,
      • Dikova T.
      Production of high-quality temporary crowns and bridges by stereolithography.
      Dikova1
      • Dikova T.
      Production of high-quality temporary crowns and bridges by stereolithography.
      did not compare 3D-printed and milled interim fixed partial dentures (FPDs), while Park et al
      • Park G.S.
      • Kim S.K.
      • Heo S.J.
      • Koak J.Y.
      • Seo D.G.
      Effects of printing parameters on the fit of implant-supported 3d printing resin prosthetics.
      focused on the marginal fit and internal gaps of interim FPDs. Therefore, the purpose of this in vitro study was to evaluate the effect of printing layer thickness on the trueness of 3-unit PMMA interim FPDs and to compare them with milled PMMA interim FPDs. The null hypotheses were that the layer thickness or fabrication technique would not affect the trueness of 3-unit interim FPDs.

      Material and methods

      The right mandibular second premolar was removed from a dentate typodont model (ANA-4; frasaco GmbH), and the right first premolar and first molar were prepared with a 1-mm-wide chamfer finish line to receive 3-unit FPDs. The maxillary and mandibular models and the occlusion were scanned with an intraoral scanner (i500; Medit) (Fig. 1). The digital scan data were converted to a standard tessellation language (STL) file that was exported to a software program (DentalCAD 2.2; exocad GmbH) to design a 3-unit interim FPD. The cement space was set at 30 μm, and the connector sizes to 9 mm2 with a modified-ridge lap pontic design.
      • Alharbi N.
      • Osman R.B.
      • Wismeijer D.
      Factors influencing the dimensional accuracy of 3D-printed full-coverage dental restorations using stereolithography technology.
      This design was converted to an STL file to generate a reference interim FPD scan STL file (RIFPD-STL) to fabricate the study groups (Fig. 2). By using this design, 40 interim FPDs were fabricated by using 2 techniques: AM (n=30) and SM (n=10). SM served as the control group.
      Figure thumbnail gr1
      Figure 1Preparations for interim FPD. A, Margin of mandibular right first premolar. B, Margin of mandibular right first molar.
      Figure thumbnail gr2
      Figure 2STL file of interim FPD. A, In contact with maxillary model. B, Occlusal aspect. C, Buccal aspect. FPD, fixed partial denture; STL, standard tessellation language.
      In the AM technique, 3 different layer thicknesses (20, 50, and 100 μm) were used to print the interim FPDs (n=10/layer thickness). The STL file of the designed interim FPD was imported to a DLP software program (SprintRay; SprintRay Inc). The support and build angle settings were determined by following the resin manufacturer’s (NextDent C&B MFH; 3D Systems) recommendation. The angle was set at 45 degrees to obtain details on the occlusal surface. The generated supports were evaluated, and any support on the margin of the interim FPD or intaglio surface was removed. To print identical interim FPDs, this configuration was duplicated 10 times and arranged on the printer’s build platform. This standard arrangement was used to fabricate each 3D-printed group. The resin (NextDent C&B MFH; 3D Systems) was mixed according to the manufacturers’ recommendations and poured into the printing material tank of the DLP printer (MoonRay S100; SprintRay Inc). Interim FPDs were then printed in 20-μm, 50-μm, and 100-μm layer thicknesses (n=10). The properties of the resin material and the printer have been previously reported.
      • Çakmak G.
      • Cuellar A.R.
      • Donmez M.B.
      • Schimmel M.
      • Abou-Ayash S.
      • Lu W.E.
      • et al.
      Effect of printing layer thickness on the trueness and margin quality of 3D-printed interim dental crowns.
      The printed interim FPDs were removed from the platform, rinsed 5 minutes in 96% clean alcohol solution ultrasonically (alcohol isopropilico; QuimiKlean) according to the manufacturers’ recommendations, and then postpolymerized (ProCure; SprintRay Inc) (405-nm LED arrays) (Fig. 3). The supports were removed with a cutoff wheel (Keystone Cut-off Wheels; Keystone Industries), and the cut surfaces smoothed with a small tungsten carbide bur (Lab Carbide #71G; Keystone Industries) to prevent alignment errors.
      Figure thumbnail gr3
      Figure 3Three-dimensionally printed interim FPDs. FPD, fixed partial denture.
      For SM, the designed STL file was inserted in the same angulation and support structures onto a PMMA block (Upcera; Shenzhen Upcera Dental Technology Corp) to mill 10 identical interim FPDs (Zenotec mini; Wieland Dental+Technik GmbH & Co KG). After milling, the supports were removed by using a cutoff wheel (Keystone Cut-off Wheels; Keystone Industries), and the sectioned areas adjusted with a small tungsten carbide bur (Lab Carbide #71G; Keystone Industries) to minimize or prevent alignment errors. The specimens were fabricated by 1 operator (G.Ç.). All AM and SM interim FPDs were evaluated under ×3.5 magnification (EyeMag Pro; Carl Zeiss) during and after adjustments to detect defects (concavities or convexities). No concavities were detected on the specimens, and all surfaces were smoothed until no convexities were observed or detected with an explorer. No intaglio surface adjustments were made.
      • Alharbi N.
      • Osman R.B.
      • Wismeijer D.
      Factors influencing the dimensional accuracy of 3D-printed full-coverage dental restorations using stereolithography technology.
      The interim FPDs were kept in lightproof boxes before scanning with an intraoral scanner. First, the intraoral scanner (i500; Medit) was calibrated, and then interim FPDs were sprayed with a thin layer of antireflective scan powder (IP Scan-Spray; IP-Division) to facilitate scanning. Then, AM, SM, and milled interim FPDs were scanned, and the scan files were converted to test-scan STL files by 1 operator (G.Ç.). The scanner had 5.3 ±0.34-μm trueness and 3.2 ±0.49-μm precision for crowns as specified by the manufacturer.
      For trueness measurements, root mean square (RMS), which indicates how far deviations are from zero between the 2 different data sets, was used.
      • Schaefer O.
      • Watts D.C.
      • Sigusch B.W.
      • Kuepper H.
      • Guentsch A.
      Marginal and internal fit of pressed lithium disilicate partial crowns in vitro: a three-dimensional analysis of accuracy and reproducibility.
      Low RMS values indicated increased 3D matching between superimposed scans and accordingly high trueness.
      International Organization for Standardization
      ISO-5725-2. Accuracy (trueness and precision) of measurement methods and results-part 2: basic method for the determination of repeatability and reproducibility of a standard measurement method.
      The RIFPD-STL and test-scan STL files were uploaded to a 3D analysis software program (Medit Link; Medit). The STL files of test scans were superimposed to the RIFPD-STL file by using the comparison application of the software program (Medit Compare v1.1.1.61; Medit). The superimposition was performed by selecting 3 reference points on the central fossa of each tooth for both RIFPD-STL and the test-scan STL (Fig. 4). To visualize and then quantify the 3D deviations, ±50 μm was used as the maximum and minimum critical (nominal) values with a ±10-μm tolerance range,
      • Wang W.
      • Yu H.
      • Liu Y.
      • Jiang X.
      • Gao B.
      Trueness analysis of zirconia crowns fabricated with 3-dimensional printing.
      and color-difference maps were generated. The test scan STL file and the RIFPD-STL were compared for the overall RMS that involves all interim FPD surfaces. The 3D analysis software program calculated the RMS from the color-difference maps. Therefore, no additional formula was used. For external, marginal, intaglio, and intaglio occlusal surface RMS values for premolar and molar teeth, test-scan STL files, and RIFPD-STL were reimported. These surfaces were separated into test-scan STL files and RIFPD-STL virtually, dividing crowns into 4 parts as reported in a previous study.
      International Organization for Standardization
      ISO-5725-2. Accuracy (trueness and precision) of measurement methods and results-part 2: basic method for the determination of repeatability and reproducibility of a standard measurement method.
      After separating, superimposition was performed again for each surface of the premolar and molar teeth at the same time. The color-difference maps were also generated for these surfaces to calculate the RMS values (Fig. 5). The areas showing greater deviations than the scale used were represented with gray and were included in the calculation.
      Figure thumbnail gr4
      Figure 4Reference points selected for superimposition of RIFPD-STL and test-scan STL files. RIFPD, reference interim fixed partial denture; STL, standard tessellation language.
      Figure thumbnail gr5
      Figure 5Color maps generated by superimposition of RIFPD-STL and test-scan STL files. A, Overall. B, External. C, Intaglio. D, Marginal. E, Intaglio occlusal. RIFPD, reference interim fixed partial denture; STL, standard tessellation language.
      Statistical evaluation of the data was performed by using a software program (R 3.6.1; The R Foundation). RMS values, depending on the layer thickness, were analyzed by using the Kruskal-Wallis tests. Any significant interactions were further resolved with Wilcoxon tests with Bonferroni correction (α=.05).

      Results

      The results of the Kruskal-Wallis test are summarized in Table 1. Figure 6 displays the RMS values of the tested surfaces for the control and different layer thickness groups. According to the results of the Wilcoxon tests with Bonferroni correction (Table 2), significant differences were found among the test groups for overall, external, and intaglio occlusal RM, in all pairwise comparisons except for the differences between the 20- and 50-μm-layer thickness interim FPDs. Interim FPDs fabricated by using a100-μm-layer thickness had the highest overall (P≤.015), external (P≤.021), and intaglio occlusal (P≤.021) RMS values, and the milled IFPDs had the lowest (P=.001). For marginal (P≥.108) and intaglio (P≥.064) RMS values, the differences among the test groups were not statistically significant.
      Table 1Median and mean ±standard deviation RMS values (μm) for printed or milled interim FPDs
      Layer Thickness (Fabrication Technique)Overall (n=10)External (n=10)Intaglio (n=10)Marginal (n=10)Intaglio Occlusal (n=10)
      Control (milled)5a (6.1 ±2.38)9.5a (9.6 ±2.41)18.5a (18.8 ±7.89)3a (4 ±2.26)3a (2.9 ±0.74)
      20 μm65b (66.4 ±10.09)55.5b (56 ±8.88)16.5a (17 ±3.13)4.5a (4.7 ±1.42)32.5b (30.7 ±5.31)
      50 μm62.5b (63.7 ±9.68)50b (52.6 ±8.68)13.5a (15.1 ±4.09)3a (3.1 ±1.1)31.5b (31.1 ±4.2)
      100 μm82.5c (85.1 ±9.11)66c (68.1 ±7.85)20a (22 ±6.77)3a (3.1 ±1.1)37.5c (38.2 ±4.54)
      Significant differences among groups are indicated with different superscript lowercase letters in same column (P<.05).
      Figure thumbnail gr6
      Figure 6RMS values of each surface according to layer thickness when compared with control (milled). RMS, root mean square.
      Table 2Adjusted P values and estimated differences (μm) for pairwise comparisons of RMS values for printed and milled interim FPDs
      SurfaceControl vs 20 μmControl vs 50 μmControl vs 100 μm20 μm vs 50 μm20 μm vs 100 μm50 μm vs 100 μm
      Overall RMS.001 (-60.3).001 (-57.6).001 (-79)>.05 (2.7).015 (-18.7).001 (-21.4)
      External RMS.001 (-46.4).001 (-43).001 (-58.5)>.05 (3.4).021 (-12.1).01 (-15.5)
      Intaglio RMS>.05 (1.8).894 (3.7)>.05 (-3.2).472 (1.9).24 (-5).064 (-6.9)
      Marginal RMS>.05 (1.8)>.05 (3.7)>.05 (-3.2).108 (1.9).108 (-5)>.05 (-6.9)
      Intaglio Occlusal RMS.001 (-27.8).001 (-28.2).001 (-35.3)>.05 (-0.4).018 (-7.5).021 (-7.1)
      P<.05 indicates significant differences between different layer thicknesses within each surface.

      Discussion

      The printing layer thickness significantly affected the trueness of AM crowns, and SM interim FPDs had higher trueness than AM FPDs. Therefore, the null hypotheses were rejected.
      Among the 3D-printed interim FPDs, the 20- and 50-μm-layer thickness groups showed no difference in trueness, but differences were found when those were compared with the 100-μm-layer thickness group in terms of overall, external, and intaglio occlusal trueness. Furthermore, a tendency for higher trueness of the intaglio surface of the 50-μm-layer thickness group was observed compared with the 100-μm-layer thickness group (P=.064 after Bonferroni correction, a rather conservative analysis approach
      • Haynes W.
      Bonferroni correction.
      ). Therefore, the intaglio surface of the 100-μm-layer thickness group may have had lower trueness. Previous studies on casts or complete dentures reported no significant influence of layer thickness on the trueness of the finished object.
      • Lo Giudice A.
      • Ronsivalle V.
      • Rustico L.
      • Aboulazm K.
      • Isola G.
      • Palazzo G.
      Evaluation of the accuracy of orthodontic models prototyped with entry-level LCD-based 3D printers: a study using surface-based superimposition and deviation analysis.
      • Dias Resende C.C.
      • Quirino Barbosa T.A.
      • Moura G.F.
      • Rizzante F.A.P.
      • Mendonça G.
      • Zancopé K.
      • et al.
      Cost and effectiveness of 3-dimensionally printed model using three different printing layer parameters and two resins.
      • Vilela Teixeira A.B.
      • Dos Reis A.C.
      Influence of parameters and characteristics of complete denture bases fabricated by 3D printing on evaluated properties: a scoping review.
      The most difficult areas to reproduce in FPDs are likely to be the thin complex structures. Therefore, a small printing layer thickness could be advantageous, particularly at thin areas with complex structures. Considering that the fissures present on the occlusal fossa are among the thinnest areas of an FPD, this phenomenon might have led to higher trueness with 20- and 50-μm-layer thickness groups than with the 100-μm-layer thickness group at the intaglio occlusal surface. When compared with the results of a study that investigated the occlusal fit of 3D-printed FPDs, among other factors, it can be seen that the smallest gap was also found in the 50-μm-layer thickness group compared with the 100-μm-layer thickness group in the present study.
      • Park G.S.
      • Kim S.K.
      • Heo S.J.
      • Koak J.Y.
      • Seo D.G.
      Effects of printing parameters on the fit of implant-supported 3d printing resin prosthetics.
      AM of interim restorations has been increasingly used in dentistry. However, the 3D printing of single crowns has been studied most often.
      • Lee W.S.
      • Lee D.H.
      • Lee K.B.
      Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system.
      ,
      • Peng C.C.
      • Chung K.H.
      • Yau H.T.
      • Ramos Jr., V.
      Assessment of the internal fit and marginal integrity of interim crowns made by different manufacturing methods.
      ,
      • Peng C.C.
      • Chung K.H.
      • Ramos Jr., V.
      Assessment of the adaptation of interim crowns using different measurement techniques.
      ,
      • Yu B.Y.
      • Son K.
      • Lee K.B.
      Evaluation of intaglio surface trueness and margin quality of interim crowns in accordance with the build angle of stereolithography apparatus 3-dimensional printing.
      ,
      • Ryu J.E.
      • Kim Y.L.
      • Kong H.J.
      • Chang H.S.
      • Jung J.H.
      Marginal and internal fit of 3D printed provisional crowns according to build directions.
      Studies comparing the accuracy of 3D-printed or milled single crowns have reported that 3D-printing could achieve similar accuracy to milling and may therefore be clinically applicable.
      • Lee W.S.
      • Lee D.H.
      • Lee K.B.
      Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system.
      ,
      • Wang W.
      • Yu H.
      • Liu Y.
      • Jiang X.
      • Gao B.
      Trueness analysis of zirconia crowns fabricated with 3-dimensional printing.
      In the present study, which may be the first focusing on the effect of layer thickness on the trueness of 3D-printed interim FPDs, the milled group performed significantly better in terms of overall, external, intaglio, and intaglio occlusal trueness. Therefore, milling may still be preferred over the 3D printing of interim FPDs, even though all analyzed aspects of the printed groups, especially for the 20- and 50-μm-layer thickness groups, were well below the 120-μm marginal gap value generally described as the clinically acceptability threshold for marginal fit.
      • Contrepois M.
      • Soenen A.
      • Bartala M.
      • Laviole O.
      Marginal adaptation of ceramic crowns: a systematic review.
      A study focusing on interim FPDs fabricated by using different 3D printing methods reported that DLP is a valid method of fabrication.
      • Dikova T.
      • Dzhendov D.
      • Ivanov D.
      • Bliznakova K.
      Dimensional accuracy and surface roughness of polymeric dental bridges produced by different 3D printing processes.
      Another study, which investigated the influence of layer thickness on the trueness of interim FPDs also achieved the best results when using a small layer thickness.
      • Dikova T.
      Production of high-quality temporary crowns and bridges by stereolithography.
      However, in this study,
      • Dikova T.
      Production of high-quality temporary crowns and bridges by stereolithography.
      the trueness of the 35-μm-layer thickness group was higher than that of the 50-μm-layer thickness group, whereas in the present study, no difference was seen between the 20- and 50-μm-layer thickness groups.
      Intraoral scanners have been used to scan the preparations on the cast for the fabrication of interim FPDs.
      • Ueda K.
      • Beuer F.
      • Stimmelmayr M.
      • Erdelt K.
      • Keul C.
      • Güth J.F.
      Fit of 4-unit FDPs from CoCr and zirconia after conventional and digital impressions.
      • Keul C.
      • Stawarczyk B.
      • Erdelt K.J.
      • Beuer F.
      • Edelhoff D.
      • Güth J.F.
      Fit of 4-unit FDPs made of zirconia and CoCr-alloy after chairside and labside digitalization--a laboratory study.
      • Diker B.
      • Tak Ö.
      Accuracy of six intraoral scanners for scanning complete-arch and 4-unit fixed partial dentures: an in vitro study.
      Earlier studies have described that the most accurate ways to obtain surface data are tactile or optical industrial-grade scanners.
      • Pan Y.
      • Tsoi J.K.H.
      • Lam W.Y.H.
      • Pow E.H.
      Implant framework misfit: a systematic review on assessment methods and clinical complications.
      ,
      • Yilmaz B.
      • Rizzo Marques V.
      • Guo X.
      • Gouveia D.
      • Abou-Ayash S.
      The effect of scanned area on the accuracy and time of anterior single implant scans: an in vitro study.
      The effect of scanning the preparation with the intraoral scanner is likely to be negligible, as this scan was only used to generate the STL data set of the interim FPDs and not for further analysis. Thus, the same STL data set was always used to fabricate the interim FPDs, which was then also used as a reference for the subsequent comparisons. The situation was different, however, for scanning the interim FPDs with the intraoral scanner. Theoretically, it would have made more sense to scan the interim FPDs with a more precise laboratory- or industrial-grade scanner in order to obtain the most accurate data sets possible for comparisons with the CAD data set. In practice, scanning with the laboratory scanner repeatedly resulted in data gaps in the areas that were difficult for the light to access, a known problem of stationary optical scanning systems.
      • González de Villaumbrosia P.
      • Martínez-Rus F.
      • García-Orejas A.
      • Salido M.P.
      • Pradíes G.
      In vitro comparison of the accuracy (trueness and precision) of six extraoral dental scanners with different scanning technologies.
      In addition, scanning 40 interim FPDs with an industrial-grade scanner was not possible for financial reasons. Therefore, an intraoral scanner was used to scan the interim FPDs, and the scans were straightforward as the movable wand of the scanner enabled the light to access the details of the interim FPDs. Despite the high trueness and precision described by the manufacturer of the applied intraoral scanner, a recent study demonstrated a precision of 13.6 ±2.5 μm for single-tooth preparation scans of this scanner.
      • Zimmermann M.
      • Ender A.
      • Mehl A.
      Local accuracy of actual intraoral scanning systems for single-tooth preparations in vitro.
      Although the accuracy of laboratory scanners is generally higher, the difference does not seem to be large; thus, the use of the intraoral scanner might be considered as a minor limitation.
      • González de Villaumbrosia P.
      • Martínez-Rus F.
      • García-Orejas A.
      • Salido M.P.
      • Pradíes G.
      In vitro comparison of the accuracy (trueness and precision) of six extraoral dental scanners with different scanning technologies.
      ,
      • Dupagne L.
      • Tapie L.
      • Lebon N.
      • Mawussi B.
      Comparison of the acquisition accuracy and digitizing noise of 9 intraoral and extraoral scanners: an objective method.
      ,
      • Pan Y.
      • Tam J.M.
      • Tsoi J.K.
      • Lam W.Y.
      • Huang R.
      • Chen Z.
      • et al.
      Evaluation of laboratory scanner accuracy by a novel calibration block for complete-arch implant rehabilitation.
      For all AM interim FPDs, a build angle of 45 degrees was used, based on the recommendations of the manufacturer. The effect of printing orientation on accuracy has been demonstrated in previous studies
      • Alharbi N.
      • Osman R.
      • Wismeijer D.
      Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations.
      ,
      • Shim J.S.
      • Kim J.E.
      • Jeong S.H.
      • Choi Y.J.
      • Ryu J.J.
      Printing accuracy, mechanical properties, surface characteristics, and microbial adhesion of 3D-printed resins with various printing orientations.
      ,
      • Osman R.B.
      • Alharbi N.
      • Wismeijer D.
      Build angle: does it influence the accuracy of 3D-printed dental restorations using digital light-processing technology?.
      ,
      • Alharbi N.
      • Osman R.B.
      • Wismeijer D.
      Factors influencing the dimensional accuracy of 3D-printed full-coverage dental restorations using stereolithography technology.
      ,
      • Yu B.Y.
      • Son K.
      • Lee K.B.
      Evaluation of intaglio surface trueness and margin quality of interim crowns in accordance with the build angle of stereolithography apparatus 3-dimensional printing.
      which have shown the best results with a printing orientation of 135 degrees (interim crowns) and 45 degrees (interim FPDs).
      • Alharbi N.
      • Osman R.
      • Wismeijer D.
      Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations.
      ,
      • Park G.S.
      • Kim S.K.
      • Heo S.J.
      • Koak J.Y.
      • Seo D.G.
      Effects of printing parameters on the fit of implant-supported 3d printing resin prosthetics.
      Consequently, the methodology used followed the recommendations in the literature, especially considering the similarity of the 45-degree and 135-degree printing orientation. The analysis of trueness by means of a best-fit algorithm and subsequent calculation of RMS deviations also followed the recommendations in the literature, which described this analysis method as the standard.
      • O'Toole S.
      • Osnes C.
      • Bartlett D.
      • Keeling A.
      Investigation into the accuracy and measurement methods of sequential 3D dental scan alignment.
      In the current study, a landmark-based superimposition was executed instead of the most commonly applied best-fit alignment. When using the best-fit algorithm, it must be assumed that the actual deviations of specific points can be underestimated, since the best possible superposition of corresponding data sets is calculated.
      • O'Toole S.
      • Osnes C.
      • Bartlett D.
      • Keeling A.
      Investigation into the accuracy and measurement methods of sequential 3D dental scan alignment.
      ,
      • Schimmel M.
      • Akino N.
      • Srinivasan M.
      • Yilmaz B.
      • Abou-Ayash S.
      Accuracy of intraoral scanning in completely and partially edentulous maxillary and mandibular jaws: an in vitro analysis.
      However, the quality of the landmark-based superimposition directly depends on the operator selecting the points.
      • O'Toole S.
      • Osnes C.
      • Bartlett D.
      • Keeling A.
      Investigation into the accuracy and measurement methods of sequential 3D dental scan alignment.
      Therefore, the superimposition in the present study was executed by a single operator with extensive knowledge in the field of digital analyses to minimize the risk of underestimating the deviations between the corresponding data sets.
      Limitations of the present study included that only one material, one 3D printer, and one intraoral scanner were used, factors that have been reported to have a significant influence on accuracy.
      • Zhang Z.C.
      • Li P.L.
      • Chu F.T.
      • Shen G.
      Influence of the three-dimensional printing technique and printing layer thickness on model accuracy.
      ,
      • Zimmermann M.
      • Ender A.
      • Mehl A.
      Local accuracy of actual intraoral scanning systems for single-tooth preparations in vitro.
      ,
      • Papadiochou S.
      • Pissiotis A.L.
      Marginal adaptation and CAD-CAM technology: a systematic review of restorative material and fabrication techniques.
      Therefore, the results should not be generalized. However, the materials tested have been used in previous studies.
      • Çakmak G.
      • Cuellar A.R.
      • Donmez M.B.
      • Schimmel M.
      • Abou-Ayash S.
      • Lu W.E.
      • et al.
      Effect of printing layer thickness on the trueness and margin quality of 3D-printed interim dental crowns.
      ,
      • Zimmermann M.
      • Ender A.
      • Mehl A.
      Local accuracy of actual intraoral scanning systems for single-tooth preparations in vitro.
      ,
      • Atria P.J.
      • Bordin D.
      • Marti F.
      • Nayak V.V.
      • Conejo J.
      • Benalcázar Jalkh E.
      • et al.
      3D-printed resins for provisional dental restorations: comparison of mechanical and biological properties.
      A sample size calculation was not performed as the present study was considered to be a pilot study. Nevertheless, the sample size was determined according to previous studies focusing on the trueness of the AM techniques,
      • Shim J.S.
      • Kim J.E.
      • Jeong S.H.
      • Choi Y.J.
      • Ryu J.J.
      Printing accuracy, mechanical properties, surface characteristics, and microbial adhesion of 3D-printed resins with various printing orientations.
      ,
      • Yu B.Y.
      • Son K.
      • Lee K.B.
      Evaluation of intaglio surface trueness and margin quality of interim crowns in accordance with the build angle of stereolithography apparatus 3-dimensional printing.
      ,
      • Çakmak G.
      • Cuellar A.R.
      • Donmez M.B.
      • Schimmel M.
      • Abou-Ayash S.
      • Lu W.E.
      • et al.
      Effect of printing layer thickness on the trueness and margin quality of 3D-printed interim dental crowns.
      ,
      • Alharbi N.
      • Alharbi S.
      • Cuijpers V.
      • Osman R.B.
      • Wismeijer D.
      Three-dimensional evaluation of marginal and internal fit of 3D-printed interim restorations fabricated on different finish line designs.
      and statistically significant differences in terms of trueness were demonstrated. A similar design and instruments were used in a previous study, which was considered when determining the sample size.
      • Çakmak G.
      • Cuellar A.R.
      • Donmez M.B.
      • Schimmel M.
      • Abou-Ayash S.
      • Lu W.E.
      • et al.
      Effect of printing layer thickness on the trueness and margin quality of 3D-printed interim dental crowns.
      In addition, the thickness of the powder used might be a limitation. Another limitation was the manual removal of support structures for all interim FPDs. Although this step was performed by the same practitioner for all reconstructions, manual rework always includes a subjective nonstandardizable component.

      Conclusions

      Based on the findings of this in vitro study, the following conclusions were drawn:
      • 1.
        The trueness of the 3D-printed interim FPDs was affected by the printing layer thickness.
      • 2.
        Layer thicknesses of 20 or 50 μm may result in higher trueness than a 100-μm-layer thickness for the printing resin, 3D printer, and settings used in the present study.
      • 3.
        The milled interim FPDs presented higher trueness than those fabricated by 3D printing, regardless of the layer thickness.

      CRediT authorship contribution statement

      Gülce Çakmak: Design, Conceptualization, Investigation, Writing – original draft. Alfonso Rodriguez Cuellar: Conceptualization, Investigation, Resources. Mustafa Borga Donmez: Writing – original draft, Writing – review & editing. Samir Abou-Ayash: Writing – original draft. Wei-En Lu: Formal analysis. Martin Schimmel: Visualization, Supervision. Burak Yilmaz: Supervision, Writing – review & editing.

      Acknowledgments

      The authors thank Laboratorio Innovando for their support in milling crowns and 3D Sequence Digital Laboratorio for their support in printing machine.

      References

        • van Noort R.
        The future of dental devices is digital.
        Dent Mater. 2012; 28: 3-12
        • Dawood A.
        • Marti Marti B.
        • Sauret-Jackson V.
        • Darwood A.
        3D printing in dentistry.
        Br Dent J. 2015; 219: 521-529
        • Beuer F.
        • Schweiger J.
        • Edelhoff D.
        Digital dentistry: an overview of recent developments for CAD/CAM generated restorations.
        Br Dent J. 2008; 204: 505-511
        • Methani M.M.
        • Revilla-León M.
        • Zandinejad A.
        The potential of additive manufacturing technologies and their processing parameters for the fabrication of all-ceramic crowns: a review.
        J Esthet Restor Dent. 2020; 32: 182-192
        • Kessler A.
        • Hickel R.
        • Reymus M.
        3D printing in dentistry-state of the art.
        Oper Dent. 2020; 45: 30-40
        • Lee W.S.
        • Lee D.H.
        • Lee K.B.
        Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system.
        J Adv Prosthodont. 2017; 9: 265-270
        • Alharbi N.
        • Osman R.
        • Wismeijer D.
        Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations.
        J Prosthet Dent. 2016; 115: 760-767
        • Dikova T.
        • Dzhendov D.
        • Ivanov D.
        • Bliznakova K.
        Dimensional accuracy and surface roughness of polymeric dental bridges produced by different 3D printing processes.
        Arch Mater Sci Eng. 2018; 2: 65-75
        • Dikova T.
        • Dzhendov D.
        • Katreva I.
        • Pavlova D.
        Accuracy of polymeric dental bridges manufactured by stereolithography.
        Arch Mater Sci Eng. 2016; 78: 29-36
        • Jockusch J.
        • Özcan M.
        Additive manufacturing of dental polymers: an overview on processes, materials and applications.
        Dent Mater J. 2020; 39: 345-354
        • Shim J.S.
        • Kim J.E.
        • Jeong S.H.
        • Choi Y.J.
        • Ryu J.J.
        Printing accuracy, mechanical properties, surface characteristics, and microbial adhesion of 3D-printed resins with various printing orientations.
        J Prosthet Dent. 2020; 124: 468-475
      1. Standard terminology for additive manufacturing - general principles and terminology. ISO/ASTM52900-15. ASTM, Committee F42 on Additive Manufacturing Technologies, West Conshohocken, PA2009: 1-19
        • Osman R.B.
        • Alharbi N.
        • Wismeijer D.
        Build angle: does it influence the accuracy of 3D-printed dental restorations using digital light-processing technology?.
        Int J Prosthodont. 2017; 30: 182-188
        • Park G.S.
        • Kim S.K.
        • Heo S.J.
        • Koak J.Y.
        • Seo D.G.
        Effects of printing parameters on the fit of implant-supported 3d printing resin prosthetics.
        Materials (Basel). 2019; 12: 2533
        • Peng C.C.
        • Chung K.H.
        • Yau H.T.
        • Ramos Jr., V.
        Assessment of the internal fit and marginal integrity of interim crowns made by different manufacturing methods.
        J Prosthet Dent. 2020; 123: 514-522
        • Peng C.C.
        • Chung K.H.
        • Ramos Jr., V.
        Assessment of the adaptation of interim crowns using different measurement techniques.
        J Prosthodont. 2020; 29: 87-93
        • Dikova T.
        Production of high-quality temporary crowns and bridges by stereolithography.
        Scr Sci Med. 2019; 5: 33-38
        • Alharbi N.
        • Osman R.B.
        • Wismeijer D.
        Factors influencing the dimensional accuracy of 3D-printed full-coverage dental restorations using stereolithography technology.
        Int J Prosthodont. 2016; 29: 503-510
        • Mai H.N.
        • Lee K.B.
        • Lee D.H.
        Fit of interim crowns fabricated using photopolymer-jetting 3D printing.
        J Prosthet Dent. 2017; 118: 208-215
        • Simoneti D.M.
        • Pereira-Cenci T.
        • Dos Santos M.B.F.
        Comparison of material properties and biofilm formation in interim single crowns obtained by 3D printing and conventional methods.
        J Prosthet Dent. 2022; 127: 168-172
        • Yu B.Y.
        • Son K.
        • Lee K.B.
        Evaluation of intaglio surface trueness and margin quality of interim crowns in accordance with the build angle of stereolithography apparatus 3-dimensional printing.
        J Prosthet Dent. 2021; 126: 231-237
        • Revilla-León M.
        • Özcan M.
        Additive manufacturing technologies used for processing polymers: current status and potential application in prosthetic dentistry.
        J Prosthodont. 2019; 28: 146-158
        • Zhang Z.C.
        • Li P.L.
        • Chu F.T.
        • Shen G.
        Influence of the three-dimensional printing technique and printing layer thickness on model accuracy.
        J Orofac Orthop. 2019; 80: 194-204
        • Çakmak G.
        • Cuellar A.R.
        • Donmez M.B.
        • Schimmel M.
        • Abou-Ayash S.
        • Lu W.E.
        • et al.
        Effect of printing layer thickness on the trueness and margin quality of 3D-printed interim dental crowns.
        Appl Sci. 2021; 11: 9246
        • Schaefer O.
        • Watts D.C.
        • Sigusch B.W.
        • Kuepper H.
        • Guentsch A.
        Marginal and internal fit of pressed lithium disilicate partial crowns in vitro: a three-dimensional analysis of accuracy and reproducibility.
        Dent Mater. 2012; 28: 320-326
        • International Organization for Standardization
        ISO-5725-2. Accuracy (trueness and precision) of measurement methods and results-part 2: basic method for the determination of repeatability and reproducibility of a standard measurement method.
        ISO, Geneva1994 (Available at:)
        • Wang W.
        • Yu H.
        • Liu Y.
        • Jiang X.
        • Gao B.
        Trueness analysis of zirconia crowns fabricated with 3-dimensional printing.
        J Prosthet Dent. 2019; 121: 285-291
        • Haynes W.
        Bonferroni correction.
        in: Dubitzky W. Wolkenhauer O. Cho K.-H. Yokota H. Encyclopedia of systems biology. Springer New York, New York, NY2013: 154
        • Lo Giudice A.
        • Ronsivalle V.
        • Rustico L.
        • Aboulazm K.
        • Isola G.
        • Palazzo G.
        Evaluation of the accuracy of orthodontic models prototyped with entry-level LCD-based 3D printers: a study using surface-based superimposition and deviation analysis.
        Clin Oral Investig. 2022; 26: 303-312
        • Dias Resende C.C.
        • Quirino Barbosa T.A.
        • Moura G.F.
        • Rizzante F.A.P.
        • Mendonça G.
        • Zancopé K.
        • et al.
        Cost and effectiveness of 3-dimensionally printed model using three different printing layer parameters and two resins.
        J Prosthet Dent. 1 July 2021; ([Epub ahead of print])https://doi.org/10.1016/j.prosdent.2021.06.006
        • Vilela Teixeira A.B.
        • Dos Reis A.C.
        Influence of parameters and characteristics of complete denture bases fabricated by 3D printing on evaluated properties: a scoping review.
        Int J Prosthodont. 17 May 2021; ([Epub ahead of print])https://doi.org/10.11607/ijp.7473
        • Ryu J.E.
        • Kim Y.L.
        • Kong H.J.
        • Chang H.S.
        • Jung J.H.
        Marginal and internal fit of 3D printed provisional crowns according to build directions.
        J Adv Prosthodont. 2020; 12: 225-232
        • Contrepois M.
        • Soenen A.
        • Bartala M.
        • Laviole O.
        Marginal adaptation of ceramic crowns: a systematic review.
        J Prosthet Dent. 2013; 110: 447-454.e10
        • Ueda K.
        • Beuer F.
        • Stimmelmayr M.
        • Erdelt K.
        • Keul C.
        • Güth J.F.
        Fit of 4-unit FDPs from CoCr and zirconia after conventional and digital impressions.
        Clin Oral Investig. 2016; 20: 283-289
        • Keul C.
        • Stawarczyk B.
        • Erdelt K.J.
        • Beuer F.
        • Edelhoff D.
        • Güth J.F.
        Fit of 4-unit FDPs made of zirconia and CoCr-alloy after chairside and labside digitalization--a laboratory study.
        Dent Mater. 2014; 30: 400-407
        • Diker B.
        • Tak Ö.
        Accuracy of six intraoral scanners for scanning complete-arch and 4-unit fixed partial dentures: an in vitro study.
        J Prosthet Dent. 5 February 2021; ([Epub ahead of print])https://doi.org/10.1016/j.prosdent.2020.12.007
        • Pan Y.
        • Tsoi J.K.H.
        • Lam W.Y.H.
        • Pow E.H.
        Implant framework misfit: a systematic review on assessment methods and clinical complications.
        Clin Implant Dent Relat Res. 2021; 23: 244-258
        • Yilmaz B.
        • Rizzo Marques V.
        • Guo X.
        • Gouveia D.
        • Abou-Ayash S.
        The effect of scanned area on the accuracy and time of anterior single implant scans: an in vitro study.
        J Dent. 2021; 109: 103620
        • González de Villaumbrosia P.
        • Martínez-Rus F.
        • García-Orejas A.
        • Salido M.P.
        • Pradíes G.
        In vitro comparison of the accuracy (trueness and precision) of six extraoral dental scanners with different scanning technologies.
        J Prosthet Dent. 2016; 116: 543-550.e1
        • Zimmermann M.
        • Ender A.
        • Mehl A.
        Local accuracy of actual intraoral scanning systems for single-tooth preparations in vitro.
        J Am Dent Assoc. 2020; 151: 127-135
        • Dupagne L.
        • Tapie L.
        • Lebon N.
        • Mawussi B.
        Comparison of the acquisition accuracy and digitizing noise of 9 intraoral and extraoral scanners: an objective method.
        J Prosthet Dent. 26 March 2021; ([Epub ahead of print])https://doi.org/10.1016/j.prosdent.2021.02.005
        • Pan Y.
        • Tam J.M.
        • Tsoi J.K.
        • Lam W.Y.
        • Huang R.
        • Chen Z.
        • et al.
        Evaluation of laboratory scanner accuracy by a novel calibration block for complete-arch implant rehabilitation.
        J Dent. 2020; 102: 103476
        • O'Toole S.
        • Osnes C.
        • Bartlett D.
        • Keeling A.
        Investigation into the accuracy and measurement methods of sequential 3D dental scan alignment.
        Dent Mater. 2019; 35: 495-500
        • Schimmel M.
        • Akino N.
        • Srinivasan M.
        • Yilmaz B.
        • Abou-Ayash S.
        Accuracy of intraoral scanning in completely and partially edentulous maxillary and mandibular jaws: an in vitro analysis.
        Clin Oral Investig. 2021; 25: 1839-1847
        • Papadiochou S.
        • Pissiotis A.L.
        Marginal adaptation and CAD-CAM technology: a systematic review of restorative material and fabrication techniques.
        J Prosthet Dent. 2018; 119: 545-551
        • Atria P.J.
        • Bordin D.
        • Marti F.
        • Nayak V.V.
        • Conejo J.
        • Benalcázar Jalkh E.
        • et al.
        3D-printed resins for provisional dental restorations: comparison of mechanical and biological properties.
        J Esthet Restor Dent. 20 February 2022; ([Epub ahead of print])https://doi.org/10.1111/jerd.12888
        • Alharbi N.
        • Alharbi S.
        • Cuijpers V.
        • Osman R.B.
        • Wismeijer D.
        Three-dimensional evaluation of marginal and internal fit of 3D-printed interim restorations fabricated on different finish line designs.
        J Prosthodont Res. 2018; 62: 218-226