Abstract
Statement of problem
How the corrosion properties of cobalt-chromium (Co-Cr) and Ti (Ti-6Al-4V) alloys,
frequently used in dental prostheses, are affected by different production methods
is unclear.
Purpose
The purpose of this in vitro study was to compare Co-Cr and Ti-6Al-4V alloys produced
by computer-aided design and computer-aided manufacturing (CAD-CAM) milling or laser
sintering in terms of corrosion, ion release, and surface hardness.
Material and methods
Co-Cr and Ti-6Al-4V specimens were produced by CAD-CAM milling and direct metal laser
sintering/selective laser sintering techniques. Testing included Vickers hardness
and then open circuit potential (OCP), Tafel extrapolation, and static immersion to
determine the corrosion behavior. The study used an inductively coupled plasma mass
spectrometer to measure ion release. The data were analyzed by using the Kruskal-Wallis
and Mann-Whitney U tests, with Bonferroni correction (α=.05).
Results
The Ti-6Al-4V laser-sintered group showed the highest Vickers hardness value (P<.008), the lowest OCP value (P<.008), and the lowest corrosion potential (Vcorr) value (P<.008). The corrosion current density (Icorr) level of the Co-Cr CAD-CAM milling group was statistically significantly lower than
that of the Ti-6Al-4V CAD-CAM milling and the Ti-6Al-4V laser-sintered groups (P<.008). The highest weight change was observed in the Ti-6Al-4V laser-sintered group.
The Co, Cr, and Ti ion emissions were higher in specimens produced by laser sintering
(P<.05), and no statistically significant difference in terms of Al and V oscillations
was found among the groups (P>.05).
Conclusions
Ti-6Al-4V alloys may be a good alternative for patients with Co-Cr allergies, but as
per the results of this study, Co-Cr still seems more suitable for clinical use.
To read this article in full you will need to make a payment
Purchase one-time access:
Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online accessOne-time access price info
- For academic or personal research use, select 'Academic and Personal'
- For corporate R&D use, select 'Corporate R&D Professionals'
Subscribe:
Subscribe to Journal of Prosthetic DentistryAlready a print subscriber? Claim online access
Already an online subscriber? Sign in
Register: Create an account
Institutional Access: Sign in to ScienceDirect
References
- Effects of chemical composition on the corrosion of dental alloys.Braz Dent J. 2012; 23: 141-148
- Biocompatibility of dental casting alloys.Crit Rev Oral Biol Med. 2002; 13: 71-84
- Clinical aspects of dental materials: Theory, practice and cases.Lippincott Williams & Wilkins/Wolters Kluwer, Philadelphia2000: 36-38
- Restorative dental materials.11th ed. Mosby/Elsevier, St. Louis2002: 449-478
- Galvanic corrosion behavior of titanium implants coupled to dental alloys.J Mater Sci Mater in Med. 2000; 11: 287-293
- Evaluation of ion release from two base-metal alloys at various pH levels.J Int Med Res. 2004; 32: 33-38
- Cobalt-chromium alloys in dentistry: An evaluation of metal ion release.J Prosthet Dent. 2015; 114: 602-608
- Comparison of metal release from various metallic biomaterials in vitro.Biomaterials. 2005; 26: 11-21
- Microporosity in casting alloys.Aust Dent J. 1975; 20: 161-166
- Corrosion in the oral cavity--potential local and systemic effects.Int Dent J. 1986; 36: 41-414
- Electrochemical Techniques in Corrosion: Status, Limitations, and Needs.J ASTM Int. 2008; 5: 101241
- Rapid manufacture of removable partial denture frameworks.Rapid Prototyp J. 2006; 12: 95-99
- Comparison of the mechanical properties and microstructures of fractured surface for Co-Cr alloy fabricated by conventional cast, 3-D printing laser-sintered and CAD/CAM milled techniques.J Korean Acad Prosthodont. 2014; 52: 67
- Fabricating titanium denture base plate by laser rapid forming.Rapid Prototyp J. 2009; 15: 133-136
- Mechanical properties of biomedical titanium alloys.Mater Sci Eng A. 1998; 243: 231-236
- A design for the additive manufacture of functionally graded porous structures with tailored mechanical properties for biomedical applications.J Manuf Process. 2011; 13: 160-170
- Alloys for prosthodontic restorations.J Prosthet Dent. 2002; 87: 351-363
- Effect of Alloy Preheating on the Mechanical Properties of As-Cast Co-Cr-Mo-C Alloys.Metall Mater Trans A. 1999; 30: 611-620
- Surface Properties and Corrosion Behavior of Co-Cr Alloy Fabricated with Selective Laser Melting Technique.Cell Biochem Biophys. 2013; 67: 983-990
- About a synthetic saliva for in vitro studies.Talanta. 2001; 53: 1103-1115
- How do titanium and Ti6Al4V corrode in fluoridated medium as found in the oral cavity? An in vitro study.Mater Sci Eng C Mater Biol Appl. 2015; 47: 384-393
- Phillips’ Science of Dental Materials.11th ed. W.B. Saunders Company/Elsevier, 2003: 570-679
- Corrosion resistance and ion release of dental prosthesis of COCR obtained by CAD-CAM milling, casting and laser sintering.Metals. 2020; 10: 1-12
- Stability and open circuit breakdown of the passive oxide film on titanium.Electrochim Acta. 1988; 33: 1143-1149
- Electropolymerization of poly(N-ethyl aniline) on mild steel: Synthesis, characterization and corrosion protection.Electrochim Acta. 2006; 51: 2949-2955
- Corrosion resistance assessment of Co-Cr alloy frameworks fabricated by CAD/CAM milling, laser sintering, and casting methods.J Prosthet Dent. 2015; 114 (Journal 2016;22:144–734): 725-734
- Comparative analysis of structure and hardness of cast and direct metal laser sintering produced Co-Cr alloys used for dental devices.Rapid Prototyp J. 2016; 22: 144-151
Article info
Publication history
Published online: August 04, 2022
Footnotes
Supported by an Istanbul University Research Fund (Project No: 31623).
Identification
Copyright
© 2022 by the Editorial Council for the Journal of Prosthetic Dentistry.