Advertisement
Journal of Prosthetic Dentistry
Dental Technique|Articles in Press

Calibrated splinting framework for complete arch intraoral implant digital scans manufactured by combining milled and additively manufacturing technologies: A dental technique

Published:December 17, 2022DOI:https://doi.org/10.1016/j.prosdent.2022.08.031

      Abstract

      Splinting frameworks are intended to increase the accuracy of complete arch intraoral digital implant scans. This article describes a technique that uses a calibrated splinting framework manufactured by combining milled and additively manufacturing technologies (IOSRing) for assisting with complete arch intraoral digital implant scanning. The splinting framework contains milled truncated cone-shape markers whose position in the metal framework is measured during the manufacturing process with a coordinate measurement machine. This framework splints the modified implant scan bodies and assists in the complete arch intraoral implant digital scanning. Computer-aided design procedures are then used to calculate the implant position on the virtual definitive implant cast by using the position of the calibrated markers as a reference.
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Journal of Prosthetic Dentistry
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Morsy N.
        • El Kateb M.
        • Azer A.
        • Fathalla S.
        Fit of zirconia fixed partial dentures fabricated from conventional impressions and digital scans: A systematic review and meta-analysis.
        J Prosthet Dent. 2021;
        • Tabesh M.
        • Nejatidanesh F.
        • Savabi G.
        • Davoudi A.
        • Savabi O.
        • Mirmohammadi H.
        Marginal adaptation of zirconia complete-coverage fixed dental restorations made from digital scans or conventional impressions: A systematic review and meta-analysis.
        J Prosthet Dent. 2021; 125: 603-610
        • Giachetti L.
        • Sarti C.
        • Cinelli F.
        • Russo D.S.
        Accuracy of digital impressions in fixed prosthodontics: A systematic review of clinical studies.
        Int J Prosthodont. 2020; 33: 192-201
        • Bandiaky O.N.
        • Le Bars P.
        • Gaudin A.
        • Hardouin J.B.
        • Cheraud-Carpentier M.
        • Mbodj E.B.
        • et al.
        Comparative assessment of complete-coverage, fixed tooth-supported prostheses fabricated from digital scans or conventional impressions: A systematic review and meta-analysis.
        J Prosthet Dent. 2022; 127: 71-79
        • Renne W.
        • Ludlow M.
        • Fryml J.
        • Schurch Z.
        • Mennito A.
        • Kessler R.
        • et al.
        Evaluation of the accuracy of 7 intraoral scanners: An in vitro analysis based on 3-dimensional comparison.
        J Prosthet Dent. 2017; 118: 36-42
        • Medina-Sotomayor P.
        • Pascual-Moscardó A.
        • Camps I.
        Relationship between resolution and accuracy of four intraoral scanners in complete-arch impressions.
        J Clin Exp Dent. 2018; 10: e361-e366
        • Nedelcu R.
        • Olsson P.
        • Nyström I.
        • Rydén J.
        • Thor A.
        Accuracy and precision of 3 intraoral scanners and accuracy of conventional impressions: A novel in vivo analysis method.
        J Dent. 2018; 69: 110-118
        • Amornvit P.
        • Rokaya D.
        • Sanohkan S.
        Comparison of accuracy of current ten intraoral scanners.
        Biomed Res Int. 2021; 2021: 2673040
        • Richert R.
        • Goujat A.
        • Venet L.
        • Viguie G.
        • Viennot S.
        • Robinson P.
        • et al.
        Intraoral scanners technologies: A review to make a successful impression.
        J Healthc Eng. 2017; 1–9
        • Revilla-León M.
        • Jiang P.
        • Sadeghpour M.
        • Piedra-Cascón W.
        • Zandinejad A.
        • Özcan M.
        • et al.
        Intraoral digital scans-Part 1: Influence of ambient scanning light conditions on the accuracy (trueness and precision) of different intraoral scanners.
        J Prosthet Dent. 2020; 124: 372-378
        • Revilla-León M.
        • Subramanian S.G.
        • Özcan M.
        • Krishnamurthy V.R.
        Clinical study of the influence of ambient light scanning conditions on the accuracy (trueness and precision) of an intraoral scanner.
        J Prosthodont. 2020; 29: 107-113
        • Revilla-León M.
        • Subramanian S.G.
        • Att W.
        • Krishnamurthy V.R.
        Analysis of different illuminance of the room lighting condition on the accuracy (trueness and precision) of an intraoral scanner.
        J Prosthodont. 2021; 30: 157-162
        • Revilla-León M.
        • Gohil A.
        • Barmak A.B.
        • Gómez-Polo M.
        • Pérez-Barquero J.A.
        • Att W.
        • et al.
        Influence of ambient temperature changes on intraoral scanning accuracy.
        J Prosthet Dent. 2022;
        • Moon Y.G.
        • Lee K.M.
        Comparison of the accuracy of intraoral scans between complete-arch scan and quadrant scan.
        Prog Orthod. 2020; 21: 36
        • Müller P.
        • Ender A.
        • Joda T.
        • Katsoulis J.
        Impact of digital intraoral scan strategies on the impression accuracy using the TRIOS Pod scanner.
        Quintessence Int. 2016; 47: 343-349
        • Pattamavilai S.
        • Ongthiemsak C.
        Accuracy of intraoral scanners in different complete arch scan patterns.
        J Prosthet Dent. 2022;
        • Gómez-Polo M.
        • Piedra-Cascón W.
        • Methani M.M.
        • Quesada-Olmo N.
        • Farjas-Abadia M.
        • Revilla-León M.
        Influence of rescanning mesh holes and stitching procedures on the complete-arch scanning accuracy of an intraoral scanner: An in vitro study.
        J Dent. 2021; 110: 103690
        • Revilla-León M.
        • Quesada-Olmo N.
        • Gómez-Polo M.
        • Sicilia E.
        • Farjas-Abadia M.
        • Kois J.C.
        Influence of rescanning mesh holes on the accuracy of an intraoral scanner: An in vivo study.
        J Den. 2021; 115: 103851
        • Revilla-León M.
        • Sicilia E.
        • Agustín-Panadero R.
        • Gómez-Polo M.
        • Kois J.C.
        Clinical evaluation of the effects of cutting off, overlapping, and rescanning procedures on intraoral scanning accuracy.
        J Prosthet Dent. 2022;
        • Revilla-León M.
        • Young K.
        • Sicilia E.
        • Cho S.H.
        • Kois J.C.
        Influence of definitive and interim restorative materials and surface finishing on the scanning accuracy of an intraoral scanner.
        J Dent. 2022; 120: 104114
        • Li H.
        • Lyu P.
        • Wang Y.
        • Sun Y.
        Influence of object translucency on the scanning accuracy of a powder-free intraoral scanner: A laboratory study.
        J Prosthet Dent. 2017; 117: 93-101
        • Lim J.H.
        • Mangal U.
        • Nam N.E.
        • Choi S.H.
        • Shim J.S.
        • Kim J.E.
        A comparison of accuracy of different dental restorative materials between intraoral scanning and conventional impression-taking: An in vitro study.
        Materials (Basel). 2021; 14: 2060
        • Dutton E.
        • Ludlow M.
        • Mennito A.
        • Kelly A.
        • Evans Z.
        • Culp A.
        • et al.
        The effect different substrates have on the trueness and precision of eight different intraoral scanners.
        J Esthet Restor Dent. 2020; 32: 204-218
        • Anh J.W.
        • Park J.M.
        • Chun Y.S.
        • Kim M.
        • Kim M.
        A comparison of the precision of three-dimensional images acquired by two intraoral scanners: effects on tooth irregularities and scanning direction.
        Korean J Orthod. 2016; 46: 3-12
        • Park J.M.
        Comparative analysis on reproducibility among 5 intraoral scanners: sectional analysis according to restoration type and preparation outline form.
        J Adv Prosthodont. 2016; 8: 354-362
        • Carbajal Mejía J.B.
        • Wakabayashi K.
        • Nakamura T.
        • Yatani H.
        Influence of abutment tooth geometry on the accuracy of conventional and digital methods of obtaining dental impressions.
        J Prosthet Dent. 2017; 118: 392-399
        • Carneiro Pereira A.L.
        • Medeiros V.R.
        • da Fonte Porto Carreiro A.
        Influence of implant position on the accuracy of intraoral scanning in fully edentulous arches: A systematic review.
        J Prosthet Dent. 2021; 126: 749-755
        • Wulfman C.
        • Naveau A.
        • Rignon-Bret C.
        Digital scanning for complete-arch implant-supported restorations: A systematic review.
        J Prosthet Dent. 2020; 124: 161-167
        • Alikhasi M.
        • Alsharbaty M.H.M.
        • Moharrami M.
        Digital implant impression technique accuracy: A systematic review.
        Implant Dent. 2017; 26: 929-935
        • Paratelli A.
        • Vania S.
        • Gómez-Polo C.
        • Ortega R.
        • Revilla-León M.
        • Gómez-Polo M.
        Techniques to improve the accuracy of complete-arch implant intraoral digital scans: A systematic review.
        J Prosthet Dent. 2021;
        • Iturrate M.
        • Minguez R.
        • Pradies G.
        • Solaberrieta E.
        Obtaining reliable intraoral digital scans for an implant-supported complete-arch prosthesis: a dental technique.
        J Prosthet Dent. 2019; 121: 237-241
        • Cappare P.
        • Sannino G.
        • Minoli M.
        • Montemezzi P.
        • Ferrini F.
        Conventional versus digital impressions for full arch screw-retained maxillary rehabilitations: a randomized clinical trial.
        Int J Environ Res Public Health. 2019; 16: 1-15
        • Mizumoto R.M.
        • Yilmaz B.
        • McGlumphy E.A.
        • Seidt J.
        • Johnston W.M.
        Accuracy of different digital scanning techniques and scan bodies for complete-arch implant-supported prostheses.
        J Prosthet Dent. 2020; 123: 96-104
        • Imburgia M.
        • Kois J.
        • Marino E.
        • Lerner H.
        • Mangano F.G.
        Continuous scan strategy (CSS): a novel technique to improve the accuracy of intraoral digital impressions.
        Eur J Prosthodont Restor Dent. 2020; 28: 128-141
      1. Patent 102021000027989. Bonadies M. Apparato e metodo per l’acquisizione di un improntadentale mediante scansione digitale intraorale, Italy. 2021.

        • Baig M.R.
        Accuracy of impressions of multiple implants in the edentulous arch: a systematic review.
        Int J Oral Maxillofac Implants. 2014; 29: 869-880
        • Jemt T.
        Three-dimensional distortion of gold alloy casting and welded titanium frameworks. Measurements of the precision of fit between completed implant prostheses and the master cast in routine edentulous situations.
        J Oral Rehabil. 1995; 22: 557-564