Abstract
Statement of problem
Static guided implant surgery may be the most accurate method of implant placement
to date. However, within the same guided implant system, whether accuracy is affected
when placing a larger diameter implant that requires more drills than a smaller diameter
implant is unclear.
Purpose
The purpose of this in vitro study was to evaluate the influence of implant diameter
on the angulation and 3-dimensional (3D) deviations of posterior single implant placement
using static guided surgery.
Material and methods
A polyurethane dental cast was made with an edentulous site at the maxillary right
first molar position. Identical implant planning for each of 3 dental implant diameters
3.3, 4.1, and 4.8 mm (Straumann BLT) were made, and surgical guides for each implant
diameters were fabricated by stereolithography. Fifteen implants of each diameter
(N=45) were placed in simulated casts. A scan body was placed and the cast was scanned
using an intraoral scanner. The positional discrepancies of implant placement, including
angulation as well as 3D implant cervical and apex area deviations, were compared
with the planned position. Linear ANOVA single factor analysis (ɑ=.05) was used, and
box plots were made.
Results
The ranges of angulation deviations for 3.3-, 4.1-, and 4.8-mm implants were 3.6 degrees
to 6.0 degrees, 3.7 degrees to 7.7 degrees, and 3.1 degrees to 6.7 degrees, respectively.
The ranges of 3D implant entry deviations of 3.3-, 4.1-, and 4.8-mm implants were
0.96 to 1.4, 0.85 to 1.72, and 0.89 to 1.78 mm, respectively. The ranges of 3D implant
apex of 3.3-, 4.1-, and 4.8-mm implants were 0.63 to 1.21, 0.64 to 1.48, and 0.48
to 1.27 mm, respectively. No statistically significant differences were found in any
of the 3 measurements: P=.67 for deviation in angulation; P=.27 for 3D implant deviation of entry; and P=.3 for 3D implant deviation of the apex.
Conclusions
Implant diameters had no significant effect on placement deviations when a single
posterior static guided surgery was used.
To read this article in full you will need to make a payment
Purchase one-time access:
Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online accessOne-time access price info
- For academic or personal research use, select 'Academic and Personal'
- For corporate R&D use, select 'Corporate R&D Professionals'
Subscribe:
Subscribe to Journal of Prosthetic DentistryAlready a print subscriber? Claim online access
Already an online subscriber? Sign in
Register: Create an account
Institutional Access: Sign in to ScienceDirect
References
- Current state of the art of computer-guided implant surgery.Periodontol 2000. 2017; 73: 121-133
- Digital implantology-a review of virtual planning software for guided implant surgery. Part II: prosthetic set-up and virtual implant planning.BMC Oral Health. 2022; 22: 23
- Accuracy of a newly developed integrated system for dental implant planning.Clin Oral Implants Res. 2009; 20: 1191-1199
- Accuracy assessment of cone beam computed tomography-derived laboratory-based surgical templates on partially edentulous patients.Clin Oral Implants Res. 2012; 23: 137-143
- In-office fabrication of dental implant surgical guides using desktop stereolithographic printing and implant treatment planning software: a clinical report.J Prosthet Dent. 2017; 118: 256-263
- Digital implantology with desktop 3D Printing.Formlab Whitepaper, Formlabs, Somerville, MA2015: 1-16
- How accurate are implant surgical guides produced with desktop stereolithographic 3-Dimensional printers?.J Oral Maxillofac Surg. 2017; 75: 2559.e1-2559.e8
- In vivo tooth-supported implant surgical guides fabricated with desktop stereolithographic printers: fully guided surgery is more accurate than partially guided surgery.J Oral Maxillofac Surg. 2018; 76: 1431-1439
- Seating accuracy of implant immediate provisional prostheses fabricated by digital workflow prior to implant placement by fully guided static computer-assisted implant surgery: an in vitro study.Clin Oral Implants Res. 2021; 32: 608-618
- Accuracy of different surgical guide designs for static computer-assisted implant surgery: an in vitro study.J Oral Implantol. 2022; 48: 351-357
- The Impact of Surgical Guide Fixation and Implant Location on Accuracy of Static Computer-Assisted Implant Surger.J Prosthodont. 2022; 31: 155-164
- Accuracy of implant position when placed using static computer-assisted implant surgical guides manufactured with two different optical scanning techniques: a randomized clinical trial.Int J Oral Maxillofac Surg. 2020; 49: 377-383
- Benefits and disadvantages of guided surgery (Flap vs. Flapless). Guided surgery in implantology.Springer International, 2021: 3-8
- Influence of surgical guide support and implant site location on accuracy of static computer-assisted implant surgery.Clin Oral Implants Res. 2019; 30: 1067-1075
- Comparison of the accuracy of implant placement using different drilling systems for static computer-assisted implant surgery: a simulation-based experimental study.Clin Implant Dent Relat Res. 2021; 23: 635-643
- Accuracy and precision of 3D-printed implant surgical guides with different implant systems: an in vitro study.J Prosthet Dent. 2020; 123: 821-828
- Influence of implant macrodesign and insertion connection technology on the accuracy of static computer-assisted implant surgery.Clin Implant Dent Relat Res. 2019; 21: 1073-1079
- Influence of the residual ridge widths and implant thread designs on implant positioning using static implant guided surgery.J Prosthodont. 10 June 2022; ([Epub ahead of print.])https://doi.org/10.1111/jopr.13557
- The influence of guided sleeve height, drilling distance, and drilling key length on the accuracy of static computer-assisted implant surgery.Clin Implant Dent Relat Res. 2019; 21: 101-107
- Influence of metal guide sleeves on the accuracy and precision of dental implant placement using guided implant surgery: an in vitro study.J Prosthodont. 8 March 2022; ([Epub ahead of print.])https://doi.org/10.1111/jopr.13503
- Intaglio surface dimension and guide tube deviations of implant surgical guides influenced by printing layer thickness and angulation setting.J Prosthodont. 2020; 29: 161-165
- Effects of two postprocessing methods onto surface dimension of in-office fabricated stereolithographic implant surgical guides.J Prosthodont. 2021; 30: 71-75
- Influence of surgeon experience on the accuracy of implant placement via a partially computer-guided surgical protocol.Int J Oral Maxillofac Implants. 2019; 34: 1177-1183
- Tolerance within the sleeve inserts of different surgical guides for guided implant surgery.Clin Oral Implants Res. 2013; 24: 630-634
- Deviations of different systems for guided implant surgery.Clin Oral Implants Res. 2017; 28: 1147-1151
- Tolerances in the production of six different implant scanbodies: a comparative study.Int J Prosthodont. 2021; 34: 591-599
Article info
Publication history
Published online: December 02, 2022
Publication stage
In Press Corrected ProofFootnotes
Funding was provided by a Mahidol University internal grant for materials other than implant fixtures.
Identification
Copyright
© 2022 by The Editorial Council for the Journal of Prosthetic Dentistry.