Advertisement
Journal of Prosthetic Dentistry

Evaluation of active tactile sensibility in a single-tooth implant opposing a natural tooth with either an immediate or delayed functional loading protocol: A parallel design clinical study

      Abstract

      Statement of problem

      High primary stability makes immediate loading more predictable, but immediately loaded implants are subjected to higher stresses and strains during the healing phase than implants that are left to heal for 3 months. Whether an earlier sensory-motor phenomenon with an immediate loading protocol helps to reduce the risk of overloading at the implant-bone interface is unclear.

      Purpose

      The purpose of this concurrent parallel design clinical study was to evaluate and compare active tactile sensibility for a single-tooth implant opposing a natural tooth in the mandibular posterior region with either a delayed or immediate functional loading -protocol.

      Material and methods

      In this parallel group randomized trial, 2 test groups were formed: the DL group comprised 20 participants with the delayed loading protocol (loading after 3 months), and the IL group comprised 20 participants with the immediate loading protocol (loading within 2 days). Natural tooth-to-tooth contact on the side contralateral to the implant site (split mouth) in both test groups was used as a control to evaluate active tactile sensibility, which was evaluated in the test and control sites of both groups by using interocclusal articulating foils of varying thickness in maximum intercuspation. Active tactile sensibility was compared between the DL and IL groups at 3 and 6 months of follow-up. The nonparametric Mann-Whitney test was used for intergroup comparisons (P=.05).

      Results

      A significant difference was found for 8-μm- and 12-μm-thick articulating foil at 3 months and for 8-μm-thick foil at 6 months (P<.05), indicating a difference in active tactile sensibility between the DL and IL groups. No implant failure was recorded in this short clinical study.

      Conclusions

      An immediate loading protocol can be performed in implants with sufficient primary stability. Upon loading, the IL group has shown more active tactile perception than the DL group.
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Journal of Prosthetic Dentistry
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Meredith N.
        Assessment of implant stability as a prognostic determinant.
        Int J Prosthodont. 1998; 11: 491-501
        • Nedir R.
        • Bischof M.
        • Szmukler-Moncler S.
        • Bernard J.P.
        • Samson J.
        Predicting osseointegration by means of implant primary stability. A resonance-frequency analysis study with delayed and immediately loaded ITI SLA implants.
        Clin Oral Implants Res. 2004; 15: 520-528
        • Abarca M.
        • Van Steenberghe D.
        • Malevez C.
        • Jacobs R.
        The neurophysiology of osseointegrated oral implants. A clinically underestimated aspect.
        J Oral Rehabil. 2006; 33: 161-169
      1. Lindhe J, Lang NP, Karring T. Clinical periodontology and implant dentistry, 5th edition, 2008 by Blackwell Munksgaard, a Blackwell Publishing company, chapter 6, page no. 108-123.

        • Batista M.
        • Bonachela W.
        • Soares J.
        Progressive recovery of osseoperception as a function of the combination of implant-supported prostheses.
        Clin Oral Implants Res. 2008; 19: 565-569
        • Kazemi M.
        • Geramipanah F.
        • Negahdari R.
        • Rakhshan V.
        Active tactile sensibility of single-tooth implants versus natural dentition: a split-mouth double-blind randomized clinical trial.
        Clin Implant Dent Relat Res. 2014; 16: 947-955
        • Enkling N.
        • Utz K.H.
        • Bayer S.
        • Stern R.M.
        Osseoperception: active tactile sensibility of osseointegrated dental implants.
        Int J Oral Maxillofac Implants. 2010; 25: 1159-1167
        • Huang Y.
        • Dessel J.V.
        • Martens W.
        • et al.
        Sensory innervation around immediately vs. delayed loaded implants: a pilot study.
        Int J Oral Sci. 2014; 7: 49-55
        • Huang Y.
        • Corpas L.S.
        • Martens W.
        • et al.
        Histomorphological study of myelinated nerve fibres in the periodontal ligament of human canine.
        Acta Odontol Scand. 2011; 69: 279-286
        • Ikeda M.
        • Oka Y.
        The relationship between nerve conduction velocity and fiber morphology during peripheral nerve regeneration.
        Brain Behav. 2012; 2: 382-390
        • Wada S.
        • Kojo T.
        • Wang Y.H.
        • et al.
        Effect of loading on the development of nerve fibers around oral implants in the dog mandible.
        Clin Oral Implants Res. 2001; 12: 219-224
        • Bonte B.
        • Linden R.W.
        • Scott B.J.
        • et al.
        Role of periodontal mechanoreceptors in evoking reflexes in the jaw-closing muscles of the cat.
        J Physiol. 1993; 465: 581-594
        • Misch C.E.
        • Kircos L.T.
        Diagnostic imaging and techniques.
        in: Misch C.E. Contemporary Implant Dentistry. 2nd ed. Mosby, St. Louis1999: 73-87
        • Jacobs R.
        • van Steenberghe D.
        Comparative evaluation of the oral tactile function by means of teeth or implant-supported prostheses.
        Clin Oral Implants Res. 1991; 2: 75-80
        • Jang K.
        • Kim Y.
        Comparison of oral sensory function in complete denture and implant-supported prosthesis wearers.
        J Oral Rehabil. 2001; 28: 220-225
        • Henry P.J.
        Oral implant restoration for enhanced oral function.
        Clin Exp Pharmacol Physiol. 2005; 32: 123-127
        • Enkling N.
        • Nicolay C.
        • Utz K.-H.
        • Jöhren P.
        • Wahl G.
        • Mericske-Stern R.
        Tactile sensibility of single-tooth implants and natural teeth.
        Clin Oral Implants Res. 2007; 18: 231-236
        • Heraud J.
        • Orofino J.
        • Trub M.
        • Mei N.
        Electrophysiologic evidence showing the existence of sensory receptors within the alveolar bone in anesthetized cats.
        Int J Oral Maxillofac Implants. 1996; 11: 800-805
        • Weiner S.
        • Sirois D.
        • Ehrenberg D.
        • Lehrmann N.
        • Simon B.
        • Zohn H.
        Sensory responses from loading of implants: a pilot study.
        Int J Oral Maxillofac Implants. 2004; 19: 44-51
        • Sakada S.
        Mechanoreceptors in fascia, periosteum and periodontal ligament.
        Bull Tokyo Med Dent Univ. 1974; 21: 11-13
        • Trulsson M.
        Sensory-motor function of human periodontal mechanoreceptors.
        J Oral Rehabil. 2006; 33: 262-273
        • Henry P.J.
        • van Steenberghe D.
        • Blomback U.
        • et al.
        Prospective multicenter study on immediate rehabilitation of edentulous lower jaws according to the Branemark Novum protocol.
        Clin Implant Dent Relat Res. 2003; 5: 137-142
        • Jivraj S.
        Screw versus cemented implant restorations: the decision-making process.
        J Dent Implant. 2018; 8: 9-19
        • Sailer I.
        • Muhlemann S.
        • Zwahlen M.
        • Hammerle C.H.
        • Schneider D.
        Cemented and screw-retained implant reconstructions: a systematic review of the survival and complication rates.
        Clin Oral Implants Res. 2012; 23: 163-201
        • Weiss E.I.
        • Kozak D.
        • Gross M.D.
        Effect of repeated closures on opening torque values in seven abutment-implant systems.
        J Prosthet Dent. 2000; 84: 194-199
        • Siamos G.
        • Winkler S.
        • Boberick K.G.
        Relationship between implant preload and screw loosening on implant-supported prostheses.
        J Oral Implantol. 2002; 28: 67-73
        • Byrne D.
        • Jacobs S.
        • O’Connell B.
        • Houston F.
        • Claffey N.
        Preloads generated with repeated tightening in three types of screws used in dental implant assemblies.
        J Prosthodont. 2006; 15: 164-171
        • Nithyapriya S.
        • Ramesh A.S.
        • Kirubakaran A.
        • Mani J.
        • Raghunathan J.
        Systematic analysis of factors that cause loss of preload in dental implants.
        J Indian Prosthodont Soc. 2018; 18: 189-195