Advertisement
Journal of Prosthetic Dentistry
Systematic Review|Articles in Press

Mechanical properties and accuracy of removable partial denture frameworks fabricated by digital and conventional techniques: A systematic review

      Abstract

      Statement of problem

      Providing a removable partial denture (RPD) can be a complex, time-consuming, and error-prone procedure. Computer-aided design and computer-aided manufacturing (CAD-CAM) techniques have shown promising clinical outcomes; however, the influence of manufacturing techniques on the properties of RPD components is unclear.

      Purpose

      The purpose of this systematic review was to determine the accuracy and mechanical properties of RPD components fabricated with conventional and digital methods.

      Material and methods

      This study followed the guidelines of the Preferred Reporting Items for Systematic Review and Meta-analyses (PRISMA) and was registered on the international prospective register of systematic reviews (PROSPERO) database (CRD42022353993). An electronic search was conducted on PubMed/MEDLINE, Scopus, Web of Science, and the Cochrane Library in August 2022. Only in vitro studies comparing the digital with the lost-wax casting technique were included. The quality of the studies was assessed by using the methodological index for nonrandomized studies (MINORS) scale.

      Results

      Of the 17 selected studies, 5 evaluated the accuracy of RPD components as well as the mechanical properties, 5 studies evaluated only the component accuracy, and another 7 evaluated only the mechanical properties. The accuracy was similar regardless of the technique, with discrepancies within clinically acceptable values (50 to 426.3 μm). The surface roughness was higher for 3D-printed clasps and lower for milled clasps (P<.05). The metal alloy significantly influenced the porosity, with the highest number of pores obtained by casting for Ti clasps and by rapid prototyping for Co-Cr clasps.

      Conclusions

      In vitro studies showed that the digital technique provided similar accuracy to that of the conventional technique within a clinically acceptable range. The manufacturing technique influenced the mechanical properties of RPD components.
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Journal of Prosthetic Dentistry
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Masri R.
        • Driscoll C.F.
        Clinical applications of digital dental technology.
        John Wiley & Sons, Ames2015: 41-47
        • Lima J.M.
        • Anami L.C.
        • Araujo R.M.
        • Pavanelli C.A.
        Removable partial dentures: use of rapid prototyping.
        J Prosthodont. 2014; 23: 588-591
        • Ye H.
        • Ning J.
        • Li M.
        • et al.
        Preliminary clinical application of removable partial denture frameworks fabricated using computer-aided design and rapid prototyping techniques.
        Int J Prosthodont. 2017; 30: 348-353
        • Hwang S.
        • An S.
        • Robles U.
        • Rumpf R.C.
        Process parameter optimization for removable partial denture frameworks manufactured by selective laser melting.
        J Prosthet Dent. 2021; 9: 1-8
        • Lee J.W.
        • Park J.M.
        • Park E.J.
        • Heo S.J.
        • Koak J.Y.
        • Kim S.K.
        Accuracy of a digital removable partial denture fabricated by casting a rapid prototyped pattern: a clinical study.
        J Prosthet Dent. 2017; 118: 468-474
        • Arnold C.
        • Hey J.
        • Schweyen R.
        • Setz J.M.
        Accuracy of CAD-CAM-fabricated removable partial dentures.
        J Prosthet Dent. 2018; 119: 586-592
        • Bajunaid S.O.
        • Altwaim B.
        • Alhassan M.
        • Alammari R.
        The fit accuracy of removable partial denture metal frameworks using conventional and 3d printed techniques: an in vitro study.
        J Contemp Dent Pract. 2019; 20: 476-481
        • Carneiro A.L.P.
        • Bezerra A.K.M.
        • Santos K.S.
        • Almeida E.O.
        • Barbosa G.A.S.
        • Carreiro A.F.P.
        Accuracy of CAD-CAM systems for removable partial denture framework fabrication: a systematic review.
        J Prosthet Dent. 2021; 125: 241-248
        • Ahmed N.
        • Abbasi M.S.
        • Haider S.
        • et al.
        Fit accuracy of removable partial denture frameworks fabricated with cad/cam, rapid prototyping, and conventional techniques: a systematic review.
        Biomed Res Int. 2021; 2021: 3194433
        • Sun S.-H.
        • Koizumi Y.
        • Kurosu S.
        • Li Y.-P.
        • Matsumoto H.
        • Chiba A.
        Build direction dependence of microstructure and high temperature tensile property of Co–Cr–Mo alloy fabricated by electron beam melting.
        Acta Biomater. 2014; 64: 154-168
        • Al Jabbari Y.S.
        Physico-mechanical properties and prosthodontic applications of Co-Cr dental alloys: a review of the literature.
        J Adv Prosthodont. 2014; 6: 138-145
        • Lapcevic A.R.
        • Jevremovic D.P.
        • Puskar T.
        • Williams R.J.
        Comparative analysis of structure and hardness of cast and direct metal laser sintering produced Co-Cr alloys used for dental devices.
        Rapid Prototyping J. 2016; 22: 144-151
        • Alageel O.
        • Abdallah M.N.
        • Alsheghri A.
        • Song J.
        • Caron E.
        • Tamimi F.
        Removable partial denture alloys processed by laser-sintering technique.
        J Biomed Mater Res B Appl Biomater. 2018; 106: 1174-1185
        • Zheng J.
        • Aarts J.M.
        • Ma S.
        • Waddell J.N.
        • Choi J.J.E.
        Different undercut depths influence on fatigue behavior and retentive force of removable partial denture clasp materials: a systematic review.
        J Prosthodont. 2022; 0: 1-8
        • Wataha J.C.
        Alloys for prosthodontic restorations.
        J Prosthet Dent. 2002; 87: 351-363
        • Lee W.F.
        • Wang J.C.
        • Hsu C.Y.
        • Peng P.W.
        Microstructure, mechanical properties, and retentive forces of cobalt-chromium removable partial denture frameworks fabricated by selective laser melting followed by heat treatment.
        J Prosthet Dent. 2022; 127: 115-121
        • Al Jabbari Y.S.
        • Karavoltsos S.
        • Kokkinos C.
        • Polychronis G.
        • Economou A.
        • Zinelis S.
        Electrochemical characterization of three types of Co-Cr based alloys manufactured by casting and selective laser melting according to ISO 10271.
        Dent Mater. 2022; 38: 1162-1172
        • Kim H.R.
        • Jang S.H.
        • Kim Y.K.
        • et al.
        Microstructures and mechanical properties of Co-Cr dental alloys fabricated by three CAD-CAM based processing techniques.
        Materials. 2016; 9: 596
        • Koutsoukis T.
        • Zinelis S.
        • Eliades G.
        • Al-Wazzan K.
        • Rifaiy M.A.
        • Al Jabbari Y.S.
        Selective laser melting technique of Co-Cr dental alloys: a review of structure and properties and comparative analysis with other available techniques.
        J Prosthodont. 2015; 24: 303-312
        • Takaichi A.
        • Suyalatu
        • Nakamoto T.
        • Joko N.
        • Nomura N.
        • Tsutsumi Y.
        • et al.
        Microstructures and mechanical properties of Co-29Cr-6Mo alloy fabricated by selective laser melting process for dental applications.
        J Mech Behav Biomed Mater. 2013; 21: 67-76
        • Takaichi A.
        • Fueki K.
        • Murakami N.
        • et al.
        A systematic review of digital removable partial dentures. Part II: CAD/CAM framework, artificial teeth, and denture base.
        J Prosthodont Res. 2022; 66: 53-67
        • Page M.J.
        • McKenzie J.E.
        • Bossuyt P.M.
        • et al.
        The PRISMA 2020 statement: an updated guideline for reporting systematic reviews.
        BMJ. 2021; 372: 71
        • Landis J.R.
        • Koch G.G.
        The measurement of observer agreement for categorical data.
        Biometrics. 1977; 33: 159-174
        • Slim K.
        • Nini E.
        • Forestier D.
        • Kwiatkowski F.
        • Panis Y.
        • Chipponi J.
        Methodological index for non-randomized studies (minors): Development and validation of a new instrument.
        ANZ J Surg. 2003; 73: 712-716
        • Gentz F.I.
        • Brooks D.I.
        • Liacouras P.C.
        • et al.
        Retentive forces of removable partial denture clasp assemblies made from polyaryletherketone and cobalt-chromium: a comparative study.
        J Prosthodont. 2022; 31: 299-304
        • Kajima Y.
        • Takaichi A.
        • Nakamoto T.
        • et al.
        Fatigue strength of Co-Cr-Mo alloy clasps prepared by selective laser melting.
        J Mech Behav Biomed Mater. 2016; 59: 446-458
        • Kaleli N.
        • Ekren O.
        • Uçar Y.
        • Ural Ç.
        Evaluation of the flexural strength of metal frameworks fabricated by sintering-based computer-aided manufacturing methods.
        J Prosthet Dent. 2022; 127: 936
        • Mayinger F.
        • Micovic D.
        • Schleich A.
        • Roos M.
        • Eichberger M.
        • Stawarczyk B.
        Retention force of polyetheretherketone and cobalt-chrome-molybdenum removable dental prosthesis clasps after artificial aging.
        Clin Oral Investig. 2021; 25: 3141-3149
        • Negm E.E.
        • Aboutaleb F.A.
        • Alam-Eldein A.M.
        Virtual evaluation of the accuracy of fit and trueness in maxillary poly(etheretherketone) removable partial denture frameworks fabricated by direct and indirect CAD/CAM techniques.
        J Prosthodont. 2019; 28: 804-810
        • Tasaka A.
        • Okano H.
        • Shimizu T.
        • Kato Y.
        • Higuchi S.
        • Yamashita S.
        Influence of reinforcement bar on accuracy of removable partial denture framework fabricated by casting with a 3D-printed pattern and selective laser sintering.
        J Prosthodont Res. 2021; 30: 213-218
        • Tasaka A.
        • Shimizu T.
        • Kato Y.
        • et al.
        Accuracy of removable partial denture framework fabricated by casting with a 3D printed pattern and selective laser sintering.
        J Prosthodont Res. 2020; 64: 224-230
        • Snosi A.M.
        • Lotfy S.M.
        • Thabet Y.G.
        • Sabet M.E.
        • Rizk F.N.
        Subtractive versus additive indirect manufacturing techniques of digitally designed partial dentures.
        J Adv Prosthodont. 2021; 13: 327-332
        • Conceição P.
        • Franco M.
        • Alves N.
        • Portugal J.
        • Neves M.C.B.
        Fit accuracy of removable partial denture metal frameworks produced by CAD-CAM – a clinical study.
        Rev Port Estomatol Med Dent Cir Maxilofac. 2021; 62: 194-200
        • Oh K.C.
        • Yun B.S.
        • Kim J.H.
        Accuracy of metal 3D printed frameworks for removable partial dentures evaluated by digital superimposition.
        Dent Mater. 2022; 38: 309-317
        • Peng P.W.
        • Hsu C.Y.
        • Huang H.Y.
        • Chao J.C.
        • Lee W.F.
        Trueness of removable partial denture frameworks additively manufactured with selective laser melting.
        J Prosthet Dent. 2022; 127: 122-127
        • Chen H.
        • Li H.
        • Zhao Y.
        • Zhang X.
        • Wang Y.
        • Lyu P.
        Adaptation of removable partial denture frameworks fabricated by selective laser melting.
        J Prosthet Dent. 2019; 122: 316-324
        • Soltanzadeh P.
        • Suprono M.S.
        • Kattadiyil M.T.
        • Goodacre C.
        • Gregorius W.
        An in vitro investigation of accuracy and fit of conventional and CAD/CAM removable partial denture frameworks.
        J Prosthodont. 2019; 28: 547-555
        • Maruo R.
        • Shimpo H.
        • Kimoto K.
        • Hayakawa T.
        • Miura H.
        • Ohkubo C.
        Fitness accuracy and retentive forces of milled titanium clasp.
        Dent Mater. 2022; 41: 414-420
        • Salim S.
        • Salleh N.M.
        • Abidin Z.Z.
        • Yunus N.
        • Rahmat R.
        • Ibrahim N.
        Physicomechanical properties of cobalt-chromium removable partial denture palatal major connectors fabricated by selective laser melting.
        J Prosthet Dent. 2022; 128: 531-537
        • Zhang M.
        • Gan N.
        • Qian H.
        • Jiao T.
        Retentive force and fitness accuracy of cobalt-chrome alloy clasps for removable partial denture fabricated with SLM technique.
        J Prosthodont Res. 2021; 66: 459-465
        • Takahashi K.
        • Torii M.
        • Nakata T.
        • Kawamura N.
        • Shimpo H.
        • Ohkubo C.
        Fitness accuracy and retentive forces of additive manufactured titanium clasp.
        J Prosthodont Res. 2020; 64: 468-477
        • Tan F.B.
        • Song J.L.
        • Wang C.
        • Fan Y.B.
        • Dai H.W.
        Titanium clasp fabricated by selective laser melting, CNC milling, and conventional casting: A comparative in vitro study.
        J Prosthodont Res. 2019; 63: 58-65
        • Torii M.
        • Nakata T.
        • Takahashi K.
        • Kawamura N.
        • Shimpo H.
        • Ohkubo C.
        Fitness and retentive force of cobalt-chromium alloy clasps fabricated with repeated laser sintering and milling.
        J Prosthodont Res. 2018; 62: 342-346
        • Rahim A.H.A.
        • Abidin Z.Z.
        • Yunus N.
        The digitalisation in cobalt-chromium framework fabrication. Surface roughness analysis: A pilot study.
        Sains Malaysia. 2021; 50: 3059-3065
        • Wang Y.
        • Guo Y.
        • Jin Y.
        • Wang Y.
        • Wang C.
        Mechanical properties, corrosion resistance, and anti-adherence characterization of pure titanium fabricated by casting, milling, and selective laser melting.
        J Biomed Mater Res. 2022; 110: 1523-1534
        • Mutschler M.
        • Schweitzer F.
        • Spintzyk S.
        • Geis-Gerstorfer J.
        • Huettig F.
        Retention forces of prosthetic clasps over a simulated wearing period of six years in-vitro: direct metal laser melting versus dental casting.
        Materials (Basel). 2020; 13: 5339
        • Schweiger J.
        • Güth J.F.
        • Erdelt K.J.
        • Edelhoff D.
        • Schubert O.
        Internal porosities, retentive force, and survival of cobalt-chromium alloy clasps fabricated by selective laser-sintering.
        J Prosthodont Res. 2020; 64: 210-216
        • Yager S.
        • Ma J.
        • Ozcan H.
        • Kilinc H.I.
        • Elwany A.H.
        • Karaman I.
        Mechanical properties and microstructure of removable partial denture clasps manufactured using selective laser melting.
        Additive Manufacturing. 2015; 8: 117-123