Abstract
Statement of problem. Immediate loading of implants may be a predictable treatment alternative when cross-arch
stabilization with a fixed provisional is observed. Purpose. This study investigated the effect of immediate masticatory loading on the stability
of single-standing dental implants with 4 different surfaces. Material and methods. A total of 40 solid screw implants (diameter 3.3 mm, length 8 mm) were placed in
the mandibles of 4 beagle dogs. Test groups included 3 hydroxyapatite (HA) coatings
of titanium plasma-sprayed (TPS) implants. Implants with TPS alone served as control.
Gold crowns were inserted 2 days after implant placement and the dogs were immediately
put on a hard food diet. Implants were followed for 6 months after loading. Clinical
and radiographic assessments of implants were performed at time of crown insertion
(baseline) and after 1, 3, and 6 months of loading. The Periotest instrument was used
for mobility measurements and radiographs were obtained for evaluation of peri-implant
radiolucency and measurement of crestal bone changes. Results. Of 40 implants, 39 displayed no discernible mobility, corresponding to successful
clinical function. Peri-implant radiolucencies were absent for all but the 1 mobile
implant. The reduction in crestal bone levels adjacent to the implants between baseline
and 6 months was statistically significant (P <.0001). No statistically significant differences in crestal bone level changes over
time were found between the various coatings demonstrating the absence of a treatment
effect initiated by the surface coatings. Conclusion. In this study in beagle dogs, immediate masticatory loading of single-standing dental
implants did not jeopardize tissue integration, provided the implants had excellent
primary stability. (J Prosthet Dent 1999;82:428-35.)
To read this article in full you will need to make a payment
Purchase one-time access:
Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online accessOne-time access price info
- For academic or personal research use, select 'Academic and Personal'
- For corporate R&D use, select 'Corporate R&D Professionals'
Subscribe:
Subscribe to Journal of Prosthetic DentistryAlready a print subscriber? Claim online access
Already an online subscriber? Sign in
Register: Create an account
Institutional Access: Sign in to ScienceDirect
References
- Intra-osseous anchorage of dental prosthesis. Experimental studies.Scand J Plastic Reconstr Surg. 1969; 3: 81-100
- The reactions of bone, connective tissue, and epithelium to endosteal implants with titanium-sprayed surfaces.J Maxillofac Surg. 1981; 9: 15-25
- Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period.Scand J Plastic Reconstr Surg. 1977; 16: l-132
- Tissue integrated prostheses: osseointegration in clinical dentistry.: Quintessence Publishing Co Inc, Chicago1985
- Theories and techniques of oral implantology. Vol. 1. : CV Mosby, St Louis1970
- A 15-year study of osseointegrated implants in the treatment of the edentulous jaw.Int J Oral Surg. 1981; 10: 387-416
- The long-term efficacy of currently used dental implants: a review and proposed criteria of success.Int J Oral Maxillofac Implants. 1986; 1: 11-25
- State of the art in oral implants.J Clin Periodontol. 1991; 18: 474-481
- Immediate loading of bilaterally splinted titanium root form implants in fixed prosthodontics—a technique re-examined: two case reports.Int J Periodontics Restorative Dent. 1995; 15: 345-361
- On the development of a new concept for othopedic implant fixation. [Thesis.].: University of Götcborg, Goteborg, Sweden1989
- Threaded versus porous-surfaced designs for implant stabilization in bone-endodontic implant model.J Biomed Mater Res. 1986; 20: 1309-1333
- Hydroxyapatite coatings convert fibrous tissue of bone around loaded implants.J Bone Joint Surg. 1993; 75: 265-270
- Hydroxyapatite coating modifies implant membrane formation. Controlled micromotion studies in dogs.Acta Orthop Scand. 1992; 63: 128-140
- Quantitative evaluation of the effect of movement at a porous coated implant-bone interface.in: The bone-biomaterial interface. : University of Toronto Press, Toronto1991: 380-387
- Bone response to early loading: the effect of surface state.in: Biological mechanisms of tooth movements and cranio facial adaptation. : Harvard Society for the Advancement of Orthodontics, Boston1996: 611-616
- Tissue integration of one-stage ITI implants. 3-year results of a longitudinal study with hollow-cylinder and hollow-screw implants.Int J Oral Maxillofac Implants. 1991; 1: 405-412
- Eight-years clinical retrospective study of titanium plasma-sprayed and hydroxyapatite-coated cylindrical implants.Int J Oral Maxillofac Implants. 1996; 11: 340-350
- Histological and histomorphometrical evaluation of tissue reactions adjacent to endosteal implants in monkeys.Clin Oral Implants Res. 1991; 2: 30-37
- Three year success rate of short ITI implants in posterior jaws.Med Buccale Chir Buccale. 1995; 1: 11-18
- Overdentures: an alternative implant methodology for edentulous patients.Int J Prosthodont. 1993; 6: 203-208
- The new concept of ITI hollow-cylinder and hollow-screw implants. Part 2. Clinical aspects, indications, and early clinical results.Int J Oral Maxillofac Implants. 1988; 3: 173-181
- Tissue integration of non submerged implants. 1-year results of a prospective study with 100 ITI hollow-screw and hollow-cylinder implants.Clin Oral Implants Res. 1990; 1: 33-40
- Radiographic evaluation of crestal bone levels adjacent to nonsubmerged titanium implants.Clin Oral Implants Res. 1992; 3: 181-188
- Comparison of healed tissue adjacent to submerged and nonsubmerged titanium dental implants. A histometric study in beagle dogs.Clin Oral Implants Res. 1996; 7: 11-19
- Benefit of the Bonefit implant system.Oral Surg Oral Med Oral Pathol. 1991; 12: 278-283
- Light and transmission electron microscopy of the intact interface between nonsubmerged titanium-coated epoxy resin implants and bone or gingiva.J Dent Res. 1992; 71: 364-371
- Comparison on the use of TPS screw-implants in the edentulous mandible.: Quintessenz Verlag, Berlin1986
- Titanium plasma-sprayed (TPS) screw implants for the reconstruction of the edentulous mandible.J Oral Maxillofac Surg. 1986; 44: 274-282
- Implant retained mandibular overdentures with immediate loading. A retrospective multicenter study on 226 consecutive cases.Clin Oral Implants Res. 1997; 8: 48-57
- Ten year results for Branemark implants immediately loaded with fixed prostheses at implant placement.Int J Oral Maxillofac Implants. 1997; 12: 495-503
- Immediate loading of threaded implants as stage l surgery in edentulous arches: ten consecutive case reports with 1- to 5-year data.Int J Oral Maxillofac Implants. 1997; 12: 319-324
- Biomechanical factors affecting the bone-dental implant interface.Clin Mater. 1992; 3: 153-201
- Periotest—a new measurement process for periodontal function. [In German.].Zahnaertztl Mitt. 1983; 73: 1129-1130
- The Periotest method for determining implant success.J Oral Implantol. 1991; 17: 410-413
- Periotest: an objective clinical diagnosis of bone apposition toward implants.Int J Oral Maxillofac Implants. 1991; 6: 55-61
- Damping characteristics of bone to implant interfaces. A clinical study with the Periotest device.Clin Oral Implants Res. 1995; 6: 31-39
- The longitudinal clinical efficacy of osseointegrated dental implants: a 3-year report.Int J Oral Maxillofac Implants. 1987; 2: 91-100
- Bone resorption around fixtures in edentulous patients treated with mandibular fixed tissue-integrated prostheses.J Prosthet Dent. 1988; 59: 59-63
- Relationship between linear and area measurements of radiographic bone levels utilizing simple-computerized techniques.J Periodont Res. 1984; 19: 191-198
- Longitudinal radiographic study of crestal bone levels adjacent nonsubmerged dental implants.J Oral Implantol. 1994; 20: 26-34
- Dental implant design-effect on bone remodeling.J Biomed Mater Res. 1991; 25: 467-483
- Evaluation of an endosseous titanium implant with a sandblasted and acid-etched surface in the canine mandible: radiographic results.Clin Oral Implants Res. 1996; 7: 240-252
- Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: a histometric study in the canine mandible.J Biomed Mater Res. 1998; 40: 1-11
- Interface histology and early loaded partially stabilized zirconia endosseous implant in initial bone healing.J Prosthet Dent. 1993; 69: 599-604
- The effects of early occlusal loading on one-stage titanium implants in beagle dogs: a pilot study.J Prosthet Dent. 1993; 69: 281-288
- Guided bone regeneration utilizing expanded polytetrafluorethylene membrane in combination with submerged and non-submerged dental implants in beagle dogs.J Periodontol. 1998; 69: 530-537
- A radiographic evaluation of bone healing around submerged and non-submerged dental implants in beagle dogs.J Periodontol. 1999; 70: 248-254
Article info
Footnotes
☆This study was supported by a grant from the ITI Foundation, Waldenburg, Switzerland.
☆☆Reprint requests to: DR H.P. WEBER, DEPARTMENT OF RESTORATIVE DENTISTRY, HARVARD SCHOOL OF DENTAL MEDICINE, 188 LONGWOOD AVE, BOSTON, MA 02115,FAX: (617)432-0901, E-MAIL: [email protected]
★0022-3913/99/$8.00 + 0. 10/1/101564
Identification
Copyright
© 1999 Editorial Council of The Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.