Clinical and radiographic evaluation of early loaded free-standing dental implants with various coatings in beagle dogs

  • Author Footnotes
    a Clinical Instructor in Prosthodontics, Department of Restorative Dentistry
    Marco Corso
    Footnotes
    a Clinical Instructor in Prosthodontics, Department of Restorative Dentistry
    Affiliations
    Harvard School of Dental Medicine, Boston, Mass
    Search for articles by this author
  • Author Footnotes
    b Postdoctoral Fellow in Prosthodontics, Department of Restorative Dentistry
    Craig Sirota
    Footnotes
    b Postdoctoral Fellow in Prosthodontics, Department of Restorative Dentistry
    Affiliations
    Harvard School of Dental Medicine, Boston, Mass
    Search for articles by this author
  • Author Footnotes
    c Assistant Professor; Director, Postdoctoral Periodontology, Department of Periodontology
    Joseph Fiorellini
    Footnotes
    c Assistant Professor; Director, Postdoctoral Periodontology, Department of Periodontology
    Affiliations
    Harvard School of Dental Medicine, Boston, Mass
    Search for articles by this author
  • Author Footnotes
    d Instructor; Director, Predoctoral Fixed Prosthodontics, Department of Restorative Dentistry
    Faheem Rasool
    Footnotes
    d Instructor; Director, Predoctoral Fixed Prosthodontics, Department of Restorative Dentistry
    Affiliations
    Harvard School of Dental Medicine, Boston, Mass
    Search for articles by this author
  • Author Footnotes
    e Researcher, Institute Straumann AG, Waldenburg, Switzerland
    Serge Szmukler-Moncler
    Footnotes
    e Researcher, Institute Straumann AG, Waldenburg, Switzerland
    Affiliations
    Harvard School of Dental Medicine, Boston, Mass
    Search for articles by this author
  • Author Footnotes
    f Nagle Associate Professor and Head, Department of Restorative Dentistry
    Hans-Peter Weber
    Footnotes
    f Nagle Associate Professor and Head, Department of Restorative Dentistry
    Affiliations
    Harvard School of Dental Medicine, Boston, Mass
    Search for articles by this author
  • Author Footnotes
    a Clinical Instructor in Prosthodontics, Department of Restorative Dentistry
    b Postdoctoral Fellow in Prosthodontics, Department of Restorative Dentistry
    c Assistant Professor; Director, Postdoctoral Periodontology, Department of Periodontology
    d Instructor; Director, Predoctoral Fixed Prosthodontics, Department of Restorative Dentistry
    e Researcher, Institute Straumann AG, Waldenburg, Switzerland
    f Nagle Associate Professor and Head, Department of Restorative Dentistry

      Abstract

      Statement of problem. Immediate loading of implants may be a predictable treatment alternative when cross-arch stabilization with a fixed provisional is observed. Purpose. This study investigated the effect of immediate masticatory loading on the stability of single-standing dental implants with 4 different surfaces. Material and methods. A total of 40 solid screw implants (diameter 3.3 mm, length 8 mm) were placed in the mandibles of 4 beagle dogs. Test groups included 3 hydroxyapatite (HA) coatings of titanium plasma-sprayed (TPS) implants. Implants with TPS alone served as control. Gold crowns were inserted 2 days after implant placement and the dogs were immediately put on a hard food diet. Implants were followed for 6 months after loading. Clinical and radiographic assessments of implants were performed at time of crown insertion (baseline) and after 1, 3, and 6 months of loading. The Periotest instrument was used for mobility measurements and radiographs were obtained for evaluation of peri-implant radiolucency and measurement of crestal bone changes. Results. Of 40 implants, 39 displayed no discernible mobility, corresponding to successful clinical function. Peri-implant radiolucencies were absent for all but the 1 mobile implant. The reduction in crestal bone levels adjacent to the implants between baseline and 6 months was statistically significant (P <.0001). No statistically significant differences in crestal bone level changes over time were found between the various coatings demonstrating the absence of a treatment effect initiated by the surface coatings. Conclusion. In this study in beagle dogs, immediate masticatory loading of single-standing dental implants did not jeopardize tissue integration, provided the implants had excellent primary stability. (J Prosthet Dent 1999;82:428-35.)
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Journal of Prosthetic Dentistry
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Brånemark PI
        • Adell R
        • Breine U.
        Intra-osseous anchorage of dental prosthesis. Experimental studies.
        Scand J Plastic Reconstr Surg. 1969; 3: 81-100
        • Schroeder A
        • Van Der Zypen E
        • Stich H
        • Sutter F.
        The reactions of bone, connective tissue, and epithelium to endosteal implants with titanium-sprayed surfaces.
        J Maxillofac Surg. 1981; 9: 15-25
        • Brånemark PI
        • Hansson BO
        • Adell R.
        Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period.
        Scand J Plastic Reconstr Surg. 1977; 16: l-132
        • Brånemark PI
        • Zarb GA
        • Albrektsson T.
        Tissue integrated prostheses: osseointegration in clinical dentistry.
        : Quintessence Publishing Co Inc, Chicago1985
        • Linkow LI
        • Chercheve R.
        Theories and techniques of oral implantology. Vol. 1. : CV Mosby, St Louis1970
        • Adell R
        • Lekholm U
        • Rockler B
        • Branemark PI.
        A 15-year study of osseointegrated implants in the treatment of the edentulous jaw.
        Int J Oral Surg. 1981; 10: 387-416
        • Albrektsson T
        • Zarb G
        • Worthington P
        • Eriksson A.
        The long-term efficacy of currently used dental implants: a review and proposed criteria of success.
        Int J Oral Maxillofac Implants. 1986; 1: 11-25
        • Albrektsson T
        • Sennerby L.
        State of the art in oral implants.
        J Clin Periodontol. 1991; 18: 474-481
        • Salama H
        • Rose LF
        • Salama M
        • Betts NJ.
        Immediate loading of bilaterally splinted titanium root form implants in fixed prosthodontics—a technique re-examined: two case reports.
        Int J Periodontics Restorative Dent. 1995; 15: 345-361
        • Carlsson LV.
        On the development of a new concept for othopedic implant fixation. [Thesis.].
        : University of Götcborg, Goteborg, Sweden1989
        • Maniatopoulos C
        • Pilliar RM
        • Smith D.
        Threaded versus porous-surfaced designs for implant stabilization in bone-endodontic implant model.
        J Biomed Mater Res. 1986; 20: 1309-1333
        • Søballe K
        • Hansen ES
        • Brockstedt-Rasmussen H
        • Bunger C.
        Hydroxyapatite coatings convert fibrous tissue of bone around loaded implants.
        J Bone Joint Surg. 1993; 75: 265-270
        • Søballe K
        • Brockstedt-Rasmussen H
        • Hansen ES
        • Bunger C.
        Hydroxyapatite coating modifies implant membrane formation. Controlled micromotion studies in dogs.
        Acta Orthop Scand. 1992; 63: 128-140
        • Pilliar RM.
        Quantitative evaluation of the effect of movement at a porous coated implant-bone interface.
        in: The bone-biomaterial interface. : University of Toronto Press, Toronto1991: 380-387
        • Szmukler-Moncler S
        • Reingewirtz Y
        • Weber HP.
        Bone response to early loading: the effect of surface state.
        in: Biological mechanisms of tooth movements and cranio facial adaptation. : Harvard Society for the Advancement of Orthodontics, Boston1996: 611-616
        • Buser D
        • Weber HP
        • Bragger U
        • Balsiger C.
        Tissue integration of one-stage ITI implants. 3-year results of a longitudinal study with hollow-cylinder and hollow-screw implants.
        Int J Oral Maxillofac Implants. 1991; 1: 405-412
        • Wheeler SL.
        Eight-years clinical retrospective study of titanium plasma-sprayed and hydroxyapatite-coated cylindrical implants.
        Int J Oral Maxillofac Implants. 1996; 11: 340-350
        • Gotfredsen K
        • Rostrup E
        • Hjørting-Hansen E
        • Stoltze K
        • Budz-Jørgensen E.
        Histological and histomorphometrical evaluation of tissue reactions adjacent to endosteal implants in monkeys.
        Clin Oral Implants Res. 1991; 2: 30-37
        • Bernard JP
        • Belser U
        • Szmukler-Moncler S
        • Martinet JP
        • Attich A
        • Saad PJ.
        Three year success rate of short ITI implants in posterior jaws.
        Med Buccale Chir Buccale. 1995; 1: 11-18
        • Mericske-Stern R
        • Zarb GA.
        Overdentures: an alternative implant methodology for edentulous patients.
        Int J Prosthodont. 1993; 6: 203-208
        • Buser DA
        • Schroeder A
        • Sutter F
        • Lang N.
        The new concept of ITI hollow-cylinder and hollow-screw implants. Part 2. Clinical aspects, indications, and early clinical results.
        Int J Oral Maxillofac Implants. 1988; 3: 173-181
        • Buser D
        • Weber HP
        • Lang NP.
        Tissue integration of non submerged implants. 1-year results of a prospective study with 100 ITI hollow-screw and hollow-cylinder implants.
        Clin Oral Implants Res. 1990; 1: 33-40
        • Weber HP
        • Buser D
        • Fiorellini JP
        • Williams RC.
        Radiographic evaluation of crestal bone levels adjacent to nonsubmerged titanium implants.
        Clin Oral Implants Res. 1992; 3: 181-188
        • Weber HP
        • Buser D
        • Donath K
        • Fiorellini JP
        • Doppolapudi V
        • Paquette D
        • et al.
        Comparison of healed tissue adjacent to submerged and nonsubmerged titanium dental implants. A histometric study in beagle dogs.
        Clin Oral Implants Res. 1996; 7: 11-19
        • ten Bruggenkate CM
        • Oosterbeck HS.
        Benefit of the Bonefit implant system.
        Oral Surg Oral Med Oral Pathol. 1991; 12: 278-283
        • Listgarten MA
        • Buser D
        • Steinemann SG
        • Donath K
        • Lang NP
        • Weber HP.
        Light and transmission electron microscopy of the intact interface between nonsubmerged titanium-coated epoxy resin implants and bone or gingiva.
        J Dent Res. 1992; 71: 364-371
        • Ledermann PD.
        Comparison on the use of TPS screw-implants in the edentulous mandible.
        : Quintessenz Verlag, Berlin1986
        • Babbush CA
        • Kent J
        • Misiek D.
        Titanium plasma-sprayed (TPS) screw implants for the reconstruction of the edentulous mandible.
        J Oral Maxillofac Surg. 1986; 44: 274-282
        • Chiapasco M
        • Gatti C
        • Rossi E
        • Haefliger W
        • Markwalder TH.
        Implant retained mandibular overdentures with immediate loading. A retrospective multicenter study on 226 consecutive cases.
        Clin Oral Implants Res. 1997; 8: 48-57
        • Schnitman PA
        • Wohrle PS
        • Rubenstein JE
        • DaSilva JD
        • Wang NH.
        Ten year results for Branemark implants immediately loaded with fixed prostheses at implant placement.
        Int J Oral Maxillofac Implants. 1997; 12: 495-503
        • Tarnow DP
        • Emtiaz S
        • Classi A.
        Immediate loading of threaded implants as stage l surgery in edentulous arches: ten consecutive case reports with 1- to 5-year data.
        Int J Oral Maxillofac Implants. 1997; 12: 319-324
        • Brunski JB.
        Biomechanical factors affecting the bone-dental implant interface.
        Clin Mater. 1992; 3: 153-201
        • Schulte W
        • d’Hoedt B
        • Lukas D
        • Muhlbradt L
        • Scholz F
        • Bretschi J
        • et al.
        Periotest—a new measurement process for periodontal function. [In German.].
        Zahnaertztl Mitt. 1983; 73: 1129-1130
        • Van Scotter DE
        • Wilson CJ.
        The Periotest method for determining implant success.
        J Oral Implantol. 1991; 17: 410-413
        • Teerlinck J
        • Quirynen M
        • Darius P
        • Van Steenberghe D.
        Periotest: an objective clinical diagnosis of bone apposition toward implants.
        Int J Oral Maxillofac Implants. 1991; 6: 55-61
        • Van Steenberghe D
        • Tricio J
        • Naert I
        • Nys M.
        Damping characteristics of bone to implant interfaces. A clinical study with the Periotest device.
        Clin Oral Implants Res. 1995; 6: 31-39
        • Cox JF
        • Zarb GA.
        The longitudinal clinical efficacy of osseointegrated dental implants: a 3-year report.
        Int J Oral Maxillofac Implants. 1987; 2: 91-100
        • Lindquist LW
        • Rockler B
        • Carlsson GE.
        Bone resorption around fixtures in edentulous patients treated with mandibular fixed tissue-integrated prostheses.
        J Prosthet Dent. 1988; 59: 59-63
        • Jeffcoat MK
        • Williams RC.
        Relationship between linear and area measurements of radiographic bone levels utilizing simple-computerized techniques.
        J Periodont Res. 1984; 19: 191-198
        • Pham AN
        • Fiorellini JP
        • Paquette D
        • Williams RC
        • Weber HP.
        Longitudinal radiographic study of crestal bone levels adjacent nonsubmerged dental implants.
        J Oral Implantol. 1994; 20: 26-34
        • Pilliar RM
        • Deporter DA
        • Watson PA
        • Valiquette N.
        Dental implant design-effect on bone remodeling.
        J Biomed Mater Res. 1991; 25: 467-483
        • Cochran DL
        • Nummikoski PV
        • Higginbottom FL
        • Hermann JS
        • Makins SR
        • Buser D.
        Evaluation of an endosseous titanium implant with a sandblasted and acid-etched surface in the canine mandible: radiographic results.
        Clin Oral Implants Res. 1996; 7: 240-252
        • Cochran DL
        • Schenk RK.
        • Lussi A
        • Higginbottom FL
        • Buser D.
        Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: a histometric study in the canine mandible.
        J Biomed Mater Res. 1998; 40: 1-11
        • Akagawa Y
        • Ichikawa Y
        • Nikai H
        • Tsuru H.
        Interface histology and early loaded partially stabilized zirconia endosseous implant in initial bone healing.
        J Prosthet Dent. 1993; 69: 599-604
        • Sagara M
        • Akagawa Y
        • Nikai H
        • Tsuru H.
        The effects of early occlusal loading on one-stage titanium implants in beagle dogs: a pilot study.
        J Prosthet Dent. 1993; 69: 281-288
        • Fiorellini JP
        • Engebretson SP
        • Donath K
        • Weber HP.
        Guided bone regeneration utilizing expanded polytetrafluorethylene membrane in combination with submerged and non-submerged dental implants in beagle dogs.
        J Periodontol. 1998; 69: 530-537
        • Fiorellini JP
        • Buser D
        • Paquette D
        • Williams RC
        • Haghighi D
        • Weber HP.
        A radiographic evaluation of bone healing around submerged and non-submerged dental implants in beagle dogs.
        J Periodontol. 1999; 70: 248-254